Our Products
Separators & Strainers
2 Products availableSwitches And Switch Boxes
2 Products availableSensors
2 Products availableSafety Switches
2 Products availableLimit Switches
2 Products availableComputer Monitor
1 Products availableLevel Switches
1 Products availableCurtains
1 Products availableOur Complete range of products are Optical Proximity Sensor, Fflameproof Limit Switch, Belt Tear Switches, Rupture Switch and Voltage Constant Current Industrial Load.
Durability.
Direct control by integrated Circuit.
Load current up to 125 A.
Load voltage up to 330/480 VAC.
Isolation voltage 2500 VAC. (4000V Optional).
Optimum Strength.
Zero voltage Turn-on, Zero Current Turn-off.
Fast switching response.
Chassis mounting.
Normal Open type.
LED Indicator Showing Relay ON status.
Reliable.
Weight-Approx 100 g.
|
Input Specification |
Rated Operational voltage |
Rated operational current AC rms. |
|||
|
50A |
75A |
90A |
125A |
||
|
30-280VAC |
330VACRMS |
PCAA-330-50 |
PCAA-330-75 |
PCAA-330-90 |
PCAA-330-125 |
|
30-280VAC |
480VACRMS |
PCAA-480-50 |
PCAA-480-75 |
PCAA-480-90 |
PCAA-480-125 |
|
Input Specifications |
Type |
|||
|
PCAA - 330/480 - |
PCAA - 330/480 - |
PCAA - 330/480 - |
PCAA - 330/480 - |
|
|
Control Voltage |
30-280 VAC |
30-280 VAC |
30-280 VAC |
30-280 VAC |
|
Input Current |
4-20mA |
4-20mA |
4-20mA |
4-20mA |
|
Drop out voltage |
45 VAC |
45 VAC |
45 VAC |
45 VAC |
|
Pick-up voltage |
180 VAC |
180 VAC |
180 VAC |
180 VAC |
|
Output Specifications |
Type |
|||
|
PCAA - 330/480 - |
PCAA - 330/480 - |
PCAA - 330/480 - |
PCAA - 330/480 - |
|
|
Load Current |
50 A |
75 A |
90 A |
125 A |
|
Peak Voltage |
800/1200V Peak |
|||
|
Range of Voltage |
160/280 VACRMS |
|||
|
Surge Current non-repetitive t=10ms(ITMS)1 |
500Apk |
1150Apk |
1250Apk |
1350Apk |
|
Voltage Drop @ Current (VTM) |
1.5 VACRMS |
2 VACRMS |
2 VACRMS |
2 VACRMS |
|
Holding Current |
250mA |
250mA |
250mA |
250mA |
|
Off-state leakage current @ voltage - (IDRM) |
10 mA |
10 mA |
10 mA |
10 mA |
|
Max Turn on time |
10 ms |
10 ms |
10 ms |
10 ms |
|
Max Turn off time |
10 ms |
10 ms |
10 ms |
10 ms |
|
I2T Fusing I2T(10ms) |
1250A2S |
5000A2S |
6600A2S |
11200A2S |
|
dv/dt @voltage (out) |
400V/μs |
400V/μs |
500V/μs |
500V/μs |
|
General Specifications |
Type |
||
|
PCAA-330/480-50 |
PCAA-330/480-75/90 |
PCAA -330/480-125 |
|
|
Dielectric strength |
Min. 2500 VAC |
Min. 2500 VAC |
Min. 2500 VAC |
|
Insulation (I/P to 0/P, I/P to case. 0/P to case |
4000 VAC rms |
4000 VAC rms |
4000 VAC rms |
|
Frequency Range |
47-63 HZ |
47-63 HZ |
47-63 HZ |
|
Operating temp. |
- 40C to +100C |
- 40C to +100C |
- 40C to +100C |
| To decrease the pollution created by the dusty condition of the conveyor, Water spraying is done on the conveyor through the nozzles. when these nozzle are activated, Water is sprayed over the conveyor to settle down the dust. these nozzle are activated when the belt is in loaded condition. Hence, This belt loading monitor plays an important roll of ensuring the belt is running with the load and water is sprayed when the conveyor is running in loaded condition of the Belt. | |
| Operation : | |
| The extension stand of belt Loading Monitor is mounted in inclined position to the action of the spring. So that Rubber Roller remain upward & the proximity switch remain OFF. When the Belt is started with Load (material), The belt will press the Rubber Roller downward thereby lifting the Mechanical Flag in front of proxirnity switch. Than Proximity switch gives the signal that can be used as a sense of Belt Loading condition. This detection of the Roller is between 5mm to 30 mm | |
The special pull cord switches are used in automobile conveyors
SPS 801 Features
Compact in designCast Aluminum enclosureAuto reset/reset with push buttonMaximurn sparn of 60 mtr.1N0+1Nc/2N0+2NcPull wire and wire breakage monitoringOne side operated
Pull to on & Pull to off Pull Cord
This switch operates when pull the wooden handle then switch will operate and when same rope is pulled the switch will reset. 1/2 Pull Cord in one enclosure with 1/2/3 tier lamp indication is available
Heavy duty enclosures for dusty environment
Ball/Bush bearing options for Cam Shaft
Wide over travel of the lever is permissible without damaging switch element
Robust spring to absorb impact from dog
Grade of protection IP 65
Cast Al/Cast Iron/Flame proof /FRP/ ABS enclosure
Contact combination 1N0+1NC/ 2N0+2NC
Heavy duty contacts 10 AMP @ 110/230/500 Volt Ac
Retaining type screws for shrouded cover
Toggled type/V leaver type limit switch
| Under/over/Zero speed protection |
| Enclosure Cast Al/Cast Iron/Flame proof/FRP/ABS enclosure |
| Grade of protection IP65 for monitoring unit/IP 67 for sensor probe |
| Multi Range model for reducing inventory |
| Range - 5 - 5000 RPM Field Selectable |
| Built in Initial start up/Nuisance time delay |
The monitoring units are to be fixed in inclined position in the direction of the belt rnovement.
The unit is provided with two 5meter long rope lengths. Appropriate length to be cut while fixing the rope. The splinters, resulting from tearing of the belt, will push out the cross connected sensing rope to acuate the switch. The potential free contacts of the switch are to be wired into appropriate warning/tripping circuit. The switch can be reset by operating the reset lever. Rope to be rnanually refixed in position while re-starting the belt operation.
| Sai Control System offers new generation Belt Rupture/Rip switch which is based on advanced micro controller technology. Belt rupture Switch consist of controller and optical transmitter and receiver for sensing. Sensor to be mounted below the belt of the conveyor. If the belt is ruptured or ripped then the conveying material will fall in the sensing area of the sensor and it will sense the falling material and the controller will trip the belt conveyor. |
for bowl liner feeders new advance version (cvcf) constant voltage, constant frequency controllers for smooth vibration and constant feed rate irrespective of change in supply voltage and frequency for genset application.
.
| VOLTAGE (volts) | MAX CURRENT ( amps) | RIPPLE P-P mv | |
|---|---|---|---|
| â–¸ | 5 V | 6 AMPS | 80 MV |
| â–¸ | 12 v | 3 AMPS | 120 MV |
| â–¸ | 15 v | 3 AMPS | 150 MV |
| â–¸ | 24 v | 2 AMPS | 150 MV |
| â–¸ | 36 v | 1.5 AMPS | 200 MV |
| â–¸ | 48 v | 1 AMPS | 200 MV |
Offers Safety Standard Type 4 when used with Controller.
Easy to install & can be mounted in any position. Vertical / Horizontal.
Non-Critical alignment between Emitter & Receiver.
Blanking / By-Passing individual channel is provided through software.
System operation is unaffected by mains power fluctuations.
Machine OFF if screen is too dirty or oily.
Barrier operates on cyclic scanning photo-electric infra-red techniques.
Various barrier heights are available for covering 90 mm to 1890 mm .
Higher covering heights available upon request.
Sensor connections are provided through plug in connectors.
Use of solid state components & special construction technique ensures that barrier is not affected by normal vibrations & shocks.
Self Checking Circuitry with two outputs continuously monitors failure of any of the beam in the system and stop the machine if failure is detected.
LED Indications are provided for status indication of each channel.
LED indications are also provided for each output.
Choice for suitable Control Unit available as per different working conditions.
Flexible fixing arrangements to suit individual requirement.
Increases productivity while maintaining required safety.