Our Products
Couplings are available to join borosilicate glass 3.3 plants pipelines together. They are designed to ensure effective sealing of the joints to avoid inducing any undue stress on the glass. Various grades are available for use in all kinds of service condition.
BACKING FLANGE with Rubber Insert | NUTS BOLTS | Complete Coupling with Rubber Insert | ||||||
DN | Reference | QTY | Reference | QTY | D | L | QTY | Reference |
25 | SCFO 1 | 2 | SCN 1 | 2 | 5/16" | 2.5" | 3 | SCTO 1 |
40 | SCFO 1.5 | 2 | SCN 1.5 | 2 | 5/16" | 2.5" | 3 | SCTO 1.5 |
50 | SCFO 2 | 2 | SCN 2 | 2 | 5/16" | 3" | 3 | SCTO 2 |
80 | SCFO 3 | 2 | SCN 3 | 2 | 5/16" | 3.5" | 6 | SCTO 3 |
100 | SCFO 4 | 2 | SCN 4 | 2 | 5/16" | 4" | 6 | SCTO 4 |
150 | SCFO 6 | 2 | SCN 6 | 2 | 5/16" | 4" | 6 | SCTO 6 |
225 | SCFO 9 | 2 | SCN 9 | 2 | 3/8" | 5" | 8 | SCTO 9 |
300 | SCFO 12 | 2 | SCN 12 | 2 | 3/8" | 6" | 12 | SCTO 12 |
400 | SCFO 16 | 2 | SCN 16 | 2 | 1/2" | 8" | 12 | SCTO 16 |
450 | SCFO 18 | 2 | SCN 18 | 2 | 1/2" | 8" | 12 | SCTO 18 |
600 | SCFO 24 | 2 | SCN 24 | 2 | 1/2" | 8" | 12 | SCTO 24 |
BACKING FLANGE with C.I. Split Asbestos | C.I. Split with Asbestos rop Insert | NUTS BOLTS | Complete Coupling with C.I. Split Asbestos | |||||
DN | Reference | QTY | Reference | QTY | D | L | QTY | Reference |
25 | SCFX 1 | 2 | SCNA 1 | 2 | 5/16 | 2.5 | 3 | SCTX 1 |
40 | SCFX 1.5 | 2 | SCNA 1.5 | 2 | 5/16 | 2.5 | 3 | SCTX 1.5 |
50 | SCFX 2 | 2 | SCNA 2 | 2 | 5/16 | 3 | 3 | SCTX 2 |
80 | SCFX 3 | 2 | SCNA 3 | 2 | 5/16 | 3.5 | 6 | SCTX 3 |
100 | SCFX 4 | 2 | SCNA 4 | 2 | 5/16 | 4 | 6 | SCTX 4 |
150 | SCFX 6 | 2 | SCNA 6 | 2 | 5/16 | 4 | 6 | SCTX 6 |
225 | SCFX 9 | 2 | SCNA 9 | 2 | 3/8 | 5 | 8 | SCTX 9 |
300 | SCFX 12 | 2 | SCNA 12 | 2 | 3/8 | 6 | 12 | SCTX 12 |
400 | SCFX 16 | 2 | SCNA 16 | 2 | 1/2 | 8 | 12 | SCTX 16 |
450 | SCFX 18 | 2 | SCNA 18 | 2 | 1/2 | 8 | 12 | SCTX 18 |
600 | SCFX 24 | 2 | SCNA 24 | 2 | 1/2 | 8 | 12 | SCTX 24 |
Since there are various terminologies in common uses to determine tube size, the following table is given to compare and relate them to the fitting size reference.
In the design of tubular structure to support glass process plant and pipeline equipment, a number of basic rules should be followed.
TUBE INCHES DIAMETER | NOMINAL BORE mm | EXTERNAL DIAMETER mm |
½” | 15 | 19.5 |
1” | 25 | 32.5 |
1 1/4” | 30 | 41.5 |
1 1/2” | 40 | 48.3 |
2” | 50 | 60.3 |
Vessels & stirrers provide best solution for all requirements encountered in production processes because of wide range of vessels available. Vessels in either unjacketed or jacketed form are essential components of many units & plants. The vessels can be combined with various components as stirrers, stirrer drive, vessel covers & heat exchangers to construct wide variety of stirred units.
Nominal Cap. Ltr. | Bulb Cap. Ltr. | Working Cap. Ltr. | Bulb dia (mm)D | Maximum Pressure (bar g) | Tolerance of dia (mm) | Tolerance in Length (mm) |
5 | 6 | 5 | 220 | 1 | ±2 | ±5 |
10 | 12 | 10 | 285 | 0.7 | ±2 | ±5 |
20 | 21 | 20 | 350 | 0.6 | ±2 | ±5 |
50 | 60 | 50 | 485 | 0.4 | ±3 | ±5 |
100 | 118 | 100 | 600 | 0.3 | ±4 | ±5 |
200 | 212 | 200 | 750 | 0.25 | ±5 | ±8 |
300 | 312 | 300 | 850 | 0.20 | ±6 | ±8 |