Server Monitoring System

  • 04 independent Channels for real time Temperatures Monitoring
  • 01 Channel for Humidity Monitoring
  • 02 Channels of volt free inputs can be taken by the system so that sensors such as Raw Power, UPS Power (Single / Three Phases), Smoke, Flood, Motion, Room Entry etc.
  • Alerts sent via SMS using GSM modem.
  • E-mail Alert through GPRS or TCPIP (Optional)
  • RS-232 port to connect PC/Laptop for downloading data
  • Threshold user denable for each sensors
  • LCD display and scroll option to view data on unit
  • LED indications.
  • Threshold can be congured on Panel as well as through RS 232 (software provided)
  • SMS request to know the current sensors status No need to visit site or open PC
  • Event or Sensors log history can be recorded and view on Panel as well as on PC/Laptop
  • Audio alert through Buzzer as well as on Hooter
  • Hooter can be mounted remotely (wired) for effective monitoring & Audio Alarm
  • System works independently. No host PC or existing IT infrastructure is required
  • Doesn't matter whether you are in ofce or out of station, you can monitor your data center any time.
  • Input power supply 220V and 50Hz
  • User friendly operations and easy installation.
  • Device can be used in many other applications such as Bank ATM, Laboratories, HUB Room, Cold Storage, Warehouse, Poultry Farms, and Hospitals etc.
.
.
View Complete Details

Power Distribution Unit

When using a normal PDU, it is possible that a short circuit in one device can shut down the complete rack or even the data center. This is not acceptable in critical applications

Also in shared data centers, there is a requirement to measure power consumption by individual server/router connected to each socket in the rack for the purpose of billing etc.

  • Each socket on PDU is metered.
  • If the equipment consumes more power than specified for the socket then the individual socket only is switched-off automatically.
  • The voltage, amperes and KVA is displayed for each individual socket on a 2 Line 40 character in built display
  • An MCB is provided to protect overloading for complete PDU.
  • 5 Nos IEC sockets, (5 Amp.) and 2 normal sockets (Type D, 5 Amp.) are provided.
  • Software for managing PDU through TCP/IP provided.
View Complete Details

Battery Monitoring System

It is usually seen that out of the 24 or 12 batteries that make a battery bank, one or more batteries may become faulty. Due to fault in one battery out of a total of 24, the performance of the complete battery bank reduces and in many cases lead to reduced backup and insufficient charging of all the batteries. Our monitoring system offers the following salient features to overcome this problem:

  • Can monitor up to 24 individual batteries online.
  • Monitoring is done for voltage on 24 x 7 basis.
  • User can define low voltage level for individual batteries.
  • If any of the battery voltage falls below the user defined limit then the system takes the following actions:
    • Display the faulty battery no. on the display.
    • Send an SMS to the user defined no./s (up to 4)
    • Activate NO/NC contact which can be monitored through NMS.
  • Battery low message is not repeated for the same battery. List of all batteries that are below the user defined limit are mentioned in same SMS
  • System can work on 20V DC - 55V DC

By continuously monitoring the old battery banks you can identify the specific battery that needs replacement instead of stressing the whole battery bank.

View Complete Details

Fire Alarm Panel

For Enclosures, specially unmanned, the following parameters need to be monitored to ensure safety of the equipment in the enclosure. Our system monitors and intimates on the NMS:

  • if there is smoke inside the shelter
  • if the temperature inside the shelter goes beyond a limit (indicating Power/AC failure or even a Fire)
  • if someone has opened the door of the shelter and is not authorized to do so

These conditions, if unchecked can compromise the security of lacs worth of equipment in the shelter and more importantly will lead to break in service and hence dissatisfied customers.

Keeping the above in mind, we have developed a comprehensive solution that incorporates all the features in a single box that operates on 48V DC.

Our Fire Panel (Advanced Model) has following features:
  • Central Control Panel
    • Intrusion detection
    • Smoke detection
    • Temperature rise detection
  • Whenever a zone is activated through its sensor, the following outputs are there
    • Corresponding zone LED lights up on Central Panel
    • Relevant message appears on LCD Display
    • In-built Buzzer sounds
    • NMS compatible NO/NC output is also activated
    • In case of Fire additionally a hooter also sounds. This hooter can be mounted outside the shelter
  • Rugged industrial design, suitable for rough usage
Temperature Alarm/Sensor features:
  • Continuous monitoring of temperature using an external temperature sensor
  • If the temperature in BTS shelter goes beyond the User defined temperature cut-off then the Temperature LED lights up on the central panel and Buzzer starts sounding. Also, the NMS is activated.
  • Once the temperature goes back to normal, the LED, Buzzer and NMS are reset automatically. The display will indicate 'System Normal'
  • The cut-off temperature can be modified by jumper setting
Fire Detection:
  • Fire detection is done using a standard Smoke Sensor that is interfaced with the Central Panel.
  • The Smoke Sensor comes with blinking LED to indicate the status of the sensor
  • The Smoke sensor draws it's power from central panel
  • In case of fire, the Fire LED lights up on the central panel and buzzer sounds. Also, the NMS is activated. In case of Fire, additionally, a hooter also sounds. This hooter can be mounted outside the shelter
  • In case the wiring of Smoke sensor is Open or Short then corresponding LED lights up and buzzer sounds. The LCD display also displays the OPEN/SHORT message.
  • RESET button is provided for resetting Fire indication.
Intrusion Detection with Entry/Exit Delay:
  • Intrusion is detected using a magnetic switch that has to be mounted on the door of the enclosure.
  • There is provision for Entry and Exit delay so that user can deactivate the alarm before the NMS starts
  • When the door is opened, the Door LED lights up on the central panel and Buzzer starts sounding. Also, the NMS is activated.
  • The user has to enter the 4 digit Password to deactivate the buzzer and NMS.
  • While leaving the enclosure, the user has to again enter the 4 digit Password to activate the Intrusion detection function
  • The exit time is as determined by the jumper setting
Entry Code:
  • Four digit Code has to be entered on the keypad provided to detect authorized entry. This is factory preset to 1234.
  • User can change the password of each panel by going into programming mode without the need to open the panel.
Specifications:

Following are the specifications of this Fire Alarm Panel:-

  • Fire Zone : One
  • Fire Sensor : Optical Type Sensor, 1 No. (Provision for second Sensor too)
  • Door Sensor : Magnetic Door Sensor, 1 No.
  • Temperature Sensor : RTD or Thermistor Sensor, 1 No.
    • Entry delay, suitable using jumpers but displayed on LCD
    • Exit delay, set table using jumpers but displayed on LCD
    • Hooter max time limit
Controls:
  • LCD display to display various error message
  • Separate switch to indicate selected settings
  • Jumper based settings
  • Front panel control: Reset switch for fire alarm
View Complete Details

MOBILE STARTER SYSTEM

  • Send SMS to START/STOP motor (or any other electric equipment).
  • Can be used with Water pumps, Industrial motors, AC, DG etc.
  • System sends SMS back if input Voltage less (Single/Three phase).
  • Get status of motor/appliance through SMS.
  • If Motor/equipment fails, then system sends SMS.
  • Electricity failure/resumption SMS during motor/device operation.
  • Automatic ON after power failure.
  • Motor ON duration SMS.
  • Can be controlled ONLY by authorized personnel up to 4 users.
  • System can't be reprogrammed in case of theft of system.
  • Easy installation can be done by user himself.
  • Motor ON warning buzzer.
  • 2x1.2AH Battery used for Power Back-up.
  • Robust construction for dusty/humid environments.
  • Saves manpower.
View Complete Details

Rack Temperature Alarm

Spaceage is a leading manufacturer of Security and Safety Solutions, especially for Telecom and Networking Domains. Spaceage has more than 6, 000 Fire Panels and 11, 000 Aviation Obstruction Lights deployed across the country. Spaceage has an enviable list of esteemed clients, each of whom is repeat customers.

"Spaceage" has variety of Networking, Rack Accessories for Power Management and Monitoring of the Racks. All the accessories mentioned herein have been developed by us including Hardware Design, Firmware, Sheet Metal, PCB, and Powder Coating etc. This gives us the flexibility to change any of our products as per your requirements. The details of our products are as under:

RACK MONITORING SOLUTIONS:
  1. Remote Monitoring System using GSM or TCP/IP:

    This system monitors various parameters of a remote site and communicates the same to a central location using GSM (SMS) or TCP/IP. By using this system it is possible to monitor hundreds of sites at a central location without the need of manning the remote site. It is a common problem that many times due to Air Conditioning failure, mains failure etc the sites could fail. By the time the network administrator knows the problem, the site is already down.

    Our system can be used to monitor various parameters as and when they happen. By using GSM technology it is possible to have an alternate route to communicate the information from the site to the central location. This is advantageous for critical sites because if while using TCP/IP, the main router/network equipment at a site goes down then there is no way to get information from the site.

    The types of parameters that can be monitored are:

    • Electrical Mains.
    • Generator On-Off.
    • Battery Voltage.
    • UPS On-Off.
    • Temperature High or Low.
    • Humidity High.
    • Intrusion/Door Open.
View Complete Details

Fire Panel

  • Mains on Green indication
  • System on Green indication
  • Fire Flashing indicator & fire tone
  • Fire sensor open/short Indicator and tone by internal speaker
  • Door open Red indicator & beeper tone

Spaceage manufactures Fire Alarm Panels for BTS shelters with one/two Smoke/Fire sensors, Temperature sensor, Intrusion sensor (Door Switch), Internal/External hooter, MCP, Reset switch etc. Advanced models also have LCD display, Digital Access code and programmable delays.

View Complete Details

Disarming System

Arming in a loose sense is switching on the system and disarming is disabling (switching off) the system. These functions can be performed using a simple switch or by using a keypad in which the user is supposed to enter a password.

In advanced systems, this may be done by an (Radio Frequency) RF remote or an Infrared remote. In cost effective systems, this is done using a traditional key that operates an electric switch. Such key-based systems are convenient for use by all age groups and offers more flexibility in terms of increasing number of authorised users. Some of the systems also have a keypad in which the owner is supposed to enter the correct password to do any arming/disarming.

The infrared remote requires that the operator of remote be in visual line of sight of the receiver that is on the control panel, where as the Radio Frequency remote can operate the control panel from anywhere (as long as the receiver is in the range) In addition to arming / disarming the control can support many other functions which may not be available (or even desired) in every control panel.

View Complete Details

Led Aviation Light

  • We FULLY meet the ICAO specifications
  • We provide uniform intensity all around as opposed to most lights in market that meet ICAO mandated requirements at certain angles only.
  • More than 24, 000 of our lights are being used around India with repeat orders from every customer

The model consists of TWO lights that are connected to a single 48V DC input. The Light sensor is single. Both the lights switch ON and OFF at the same time. The SMPS is in-built inside the light base.

TWIN DOME 230V AC Model (SSSL-04TAC)

The model consists of TWO lights that are connected to a single SMPS that is mounted in the shelter. The Light sensor is also connected to the SMPS outside the shelter. Both the lights switch ON and OFF at the same time. Features of each light are:

View Complete Details

Glass Break Detector

The glass break sensor senses the noise produced by the breaking of glass or when Glass is hit by a metallic object. The cracking noise made as glass is broken contains higher frequencies in addition to the audible sound. In a well designed glass breaking sensor, only the energy produced at such specific frequencies is used for triggering an alarm and in this way false alarms from normal sounds are ignored by the alarm triggering circuit.

Improved version uses advanced digital filtering technique to completely reject background noises below the cut-out frequency and advanced signal processing to detect fast attack signals, yet ignoring sounds that build up gradually with time such as approaching automobiles, aircraft or screeching brakes. This type of glass break detector has a detection range within 50' radius and therefore can cover more than one glass window as long as it is within range. The optimal mounting location for these detectors is in a corner approximately 1 inch from the widow frame. The reason for this is that the shock waves tend to concentrate in the corners of the window.

View Complete Details

GSM UPS SYSTEM

Almost every large UPS user has faced a situation where the UPS has shut down without warning leading to failure of critical equipment. This becomes specially critical in during unmanned hours.

We have developed a system that can send SMS / E-mail in case

  • Mains Fail.
  • Mains Resume.
  • UPS Fail.
  • UPS Resume.
View Complete Details

Electric Panels

ADVANTAGES:
  • Get real time automatic SMS for:
    • 4 Temperature Zones
    • Humidity
    • Raw Power etc.
    • Smoke Sensor
    • UPS Power
  • User defined cut-off for all parameters.
  • Automatic SMS to 4 phone numbers followed by rings and LED, Buzzer / Hooter (up to 25 meter) incase user defined limits are crossed.
  • E-mail alerts through TCP-IP or independent GPRS.
  • Alarm message reaches you anywhere in the world even if your LAN is down.
  • Log file for up to 1500 alarms. Additional 1500 log for time interval based actual parameters.
  • Windows based software provided to download events through RS232 port (Date and time based reports available).

For more details .
  • Guard Tour Monitor
  • Gates and Barriers
  • Security Lights
  • Photosensitive Lights
  • Metal detectors
  • X-ray Machines
View Complete Details

Lightening Arrester

Spaceage manufactures simple and most effective lightening arresters incorporating the various findings from different studies. It is an established fact that for lightening arresters has to be effective, the surge produced by lightening should be earthed using a joint less conductor. That's why the copper strip/cable that is brought from the lightening arrester does not have joints. The joints are braised so that a good permanent electrical contact is established. But somehow many people overlook the fact that in some of the lightening arresters in the market, there are three joints. This is true for a typical 5 spike model that has a joint where the spike is screwed into the central dome, which in turn is screwed on to the central rod/pipe, which in turn is screwed to the base. These three joints will kill the effectiveness of the Lightening arrester.

Spaceage's arrester is a single rod that has a spike at one end and has an insulation arrangement at the other for mounting. No joints. In fact, most of the internationally available lightening arresters also have the same principle. And importantly, Spaceage arrester would typically cost one third as compared to other ineffective models.

View Complete Details

Rack Temperature Logger

The system is used to monitor environment for each rack or at Data Center level to pre-empt any problems that may arise due to variance in parameters like temperature, humidity, voltages, door open etc. Instead of Administrator going to each rack to collect the data, the same is consolidated by the system on a central server and presented in a Live Dashboard format.

The system is intelligent enough to monitor the parameters and also inform relevant people thru SMS when such an eventuality happens.

The system consists of three parts:

Monitoring Hardware A 19/21" rack mountable system that comes with all the sensors and intelligent Firmware with TCP/IP connectivity.

Server Software This consolidates information from almost unlimited number of 'Monitoring Hardware' at remote locations and present the same in a user friendly format.

Intimation solution This consists of a modem and software that sends SMS to relevant people whenever an event occurs

Optional:

  • User can select number of sensors as there may not be need to monitor one or more inputs
  • We can also use GPRS with a modem to connect different sites instead of TCP/IP
View Complete Details

Ultrasonic Detector

Ultrasonic motion detectors generate inaudible sound waves/patterns and recognize a disturbance in those patterns caused by an intruder. These are compact devices which make the installation simple. The ultrasonic transmitter transmits high frequency, inaudible sound waves into the protected area and the receiver picks up the energy reflected back to the unit by the walls, ceiling, floors and other fixed objects in the enclosed area. The received signal is processed and analyzed by the signal processor. An intruder moving into the protected area causes some waves to be reflected resulting in change of pattern and hence change in strength of signal received by Receiver. If there is no movement within the area of coverage, the signal strength remains unchanged. These changes causes the unit to detect the movement and sound the alarm.

While both ultrasonic and microwave use the same principle to detect motion, a microwave uses a much higher frequency and as a result it can detect motion through most walls & partitions. Motion Sensors generate signals in the range between 19 and 40 kilo hertz which is above the frequencies that a normal ear can hear. Ultrasonic energy is contained completely in the area it is operating. It will not penetrate walls or windows but is absorbed by carpet, curtains and false ceiling. Obstructions within a room will reflect the ultrasonic energy and distort its shape pattern.

Typical detection range of ultrasonic units is 20 feet wide by 30 feet long in a room with a ceiling up to 12 feet high. Ultrasonic detectors can be prone to false alarms due to excessive air currents and other extraneous ultrasonic noises. Proper application and installation of this equipment is very important. The ultrasonic units can be mounted on any plane, vertical or horizontal or in any location - ceilings, walls, corridors - projecting the ultrasonic pattern at any desired angle. These units provide volumetric space protection.

View Complete Details

Led Based Aviation Obstruction Light

We are offering led based aviation obstruction light.Spaceage is the pioneer in uniform intensity led based aviation lights as per icao standards. We offer 24v dc48v dc230v ac, 10cd33cd lights (type a type b) lights with or without lightphoto sensorsswitch. We offer internalexternal smpssensor.
View Complete Details

Aviation Obstruction Light

Spaceage is the pioneer in uniform intensity LED based Aviation Lights as per ICAO standards. We offer 24V DC/48V DC/230V AC, 10cd/33cd lights (Type A / Type B) lights with or without light/photo sensors/switch. We offer internal/external SMPS/Sensor.

LED Aviation Obstruction Light/LampOur distinguishing features are:
  • We FULLY meet the ICAO specifications
  • We provide uniform intensity all around as opposed to most lights in market that meet ICAO mandated requirements at certain angles only.
  • We can produce product as per tender / specifications and save costs.
Range of Models

We have many versions of Aviation Lights to suit every need. We offer following broad categories

  • Voltage 24V DC/48V DC/230V AC
  • Sensor Internal or External
  • Light intensity Low intensity Type A or Type B (for stationary low height objects)
  • SMPS External/Internal, Outdoor
  • Bird Spike With or without
General features
  • Each light consists of 135/162 (depends upon model desired) Surface mounted High Powered LEDs sourced from reliable and reputed sources.
  • The LED's are mounted on special base that places the LEDs in absolutely uniform arrangement (as demonstrated in subsequent pages). Such an arrangement requires no additional lens or filter is to give UNIFORM light intensity. This also reduces any losses that are usually associated with lens etc. This is a UNIQUE arrangement devised by us.
  • Body is made from Aluminium with bright orange powder coating or as per specs
  • Totally sealed from moisture and dust.
  • Silicon based permanent seals are used that are durable and absorbs the expansion of material in hot weather.
  • Confirms to ICAO Annexure 14, for low intensity Type B obstruction light
  • The light produced by LED's is RED in color and no additional color filters/Lens are required. (The filters / lens absorb part of light and fade after some time)
  • Since the light produced by LED is directional in nature there are no reflectors or obstructions to reduce the dissipation of light.
  • Our External SMPS model has option to bypass external sensor so that in case there is a problem with sensor, it can just be bypassed by flick of a switch. This gives enough time for operations staff to change the light, as and when convenient.
View Complete Details

Cold Storage Monitoring

Cold Storage Monitoring available for other applications like Bank ATM, Hospitals, Hotels, BTS System, Hub Rooms, Cold Storage, Warehouse etc.
View Complete Details

Twin Aviation Obstruction Lights

Twin aviation obstruction lights are connected to a single control panel. The control panel ensure that when the first light fails to switch on (or consumes less than 75% of rated current) then the standby light is switched on.
View Complete Details

Solar Aviation Light

Solar aviation light is an ideal solution for passive shelters where the electricity connection as well as generator may not be there.
View Complete Details

Battery Bank Voltage Monitor

battery bank voltage monitor is usually seen that out of the 24 or 12 batteries that make a battery bank, one or more batteries may become faulty.
View Complete Details

Advanced Fire Alarm Panel For Bts Shelters

We are offering advanced fire alarm panel for bts shelters.A highly recognized and leading web solution company in india, providing many types of web services at affordable prices such as advanced fire alarm panel for bts shelters in india.
View Complete Details