Post Buy Requirement
SL
Mumbai, Maharashtra, India
Add Review

Other Products / Services #5394260

COD Analysis System

cod analysis system is one of the pollution monitoring instruments. Cod analysis requires digestion of samplers using potassium dichromate and sulphuric acid. Spectralab offers three models of cod digesters : model 2015mcod digester for 20 ml sample size, model 5015m for 50 ml sample size and 2025m for 2-5 ml sample size. The digested sample is then titrated against fes04 , for which model ct 15 cod titrator is specially designed. Determinations of cod are commonly made on samples of waste waters or natural waters contaminated by domestic or industrial wastes. Dichromate reflux method is used for the same.

View Complete Details

Coulometric KF Titrator

Coulometric titration process is a titration method in which constant current electrolysis is carried out using electrolytic control method. Spectralab Model CM-08 is based on the principle of coulometry. It detects the moisture content as low as 1 ppm. In this method iodine is generated byintermittent electrolysis in the titration vessel. The moisture content is calculated using the titration time and the constant current passed. It is micro controller based, reliable and easy to use. It can be used either with single reagent or anolyte & catholyte reagent as per the application.Direct result in selected units of concentration in document format date, time, sample name, titration no. operators name etc. Set up mode to help user to set the instrument in operating condition.Automatic drift compensation.Statistics to give Average & standard deviation.Single shift key for quick alphanumeric entries.GLP / 21 CFR Part 11 Compliant.

View Complete Details

Composite Sampler

For collection of water sample at predefined time intervals, consisting of a pump with programmable controller. The quality of effluent does not remain same throughout the day. It therefore becomes essential to monitor various parameter again & again at different intervals to have correct idea. Using composite sampler you can get representative sample from 1lt to 10 lt in 24 hours time depending on the programme you select. This will help you reducing time & cost of analysis.

View Complete Details

Bod Monitor

BOD Biochemical oxygen demand is one of the important parameter of effluent analysis. The SPECTRALAB Microcontroller based BOD Monitor system is based on well known principle of Electrolytic Respirometry In this method exact quantity of oxygen is supplied as per demand & the oxygen required can be directly noted in mg/liter against time.BOD Monitor is designed to measure the oxygen uptake of a given sample continuously. It consist of Cell assembly, Electronic Unit & Magnetic Stirrer. The Sample is kept in continuous stirring to ensure constant absorption of OXYGEN.BOD is to be reported at 27C for 3 days. However, with this instrument after studying routine samples the BOD can be predicted with in 1 to 2 days by using prediction factor.

APPLICATIONS :

Study of Biodegradability & Toxicity of organic compound.Study of reaction kinetics biodegradation of specific waste and its removal from the environment.Study of specific bacterial strength and enzymatic systems responsible for biodegradation of specific compound.Study of oxygen up take rate of biomass and their viable concentration present in activated sludge systems.Monitoring of the performance of effluent treatment systems with greater speed and reliability.

SPECIFICATION :

Microcontroller BasedElectrolytic Respirometry principleNumber samples 2 at a time. Smaple size 1 liter.Dilution range upto 500 mg/ltr.Continuous & hourly display of result with graph.Prediction factor to predict result at 24 or 36 hrs.Dilution factor for automatic multiplication.Digital temperature indication of surrounding temperature.Soft touch membrane key board.16 character duel line backlighted display.Real time clock to give date & time of analysis.Data protection in case of power failure.Printer interface for dot matrix printer.

View Complete Details

Thermo Reactor

Ideally suited for COD digestion and other similar digestions. Accomodates 25 Nos.Closed cap vials of 16mm diameter Digital timer turns off power automatically after elapsed time.

View Complete Details

TURBIDITY METER

The common Turbidity Meters use incandescent lamps as light sources, which emit broad spectrum. The wide range of wavelengths can cause colorimetric interference in turbidity readings. Also, incandescent lamp output tends to reduce over time. Due to this frequent replacement of lamp & calibration is required. Model NT 4000 uses a narrow band monochromatic light source ( I R LED ). It has a long life & very less wavelength interference. Spectralab Model NT 4000 Turbidity Meter is the most advanced portable microcontroller based Turbidity Meter. It is based on nephelometric and ratiometric principles of turbidity measurement. It uses LED & meets EPA 180.1 and ISO 7027 as well as an infrared ratio ( IR ratio ) mode that gives results in accordance with EPA GLI method 2. It has a memory to store 40 results. The data can be transferred to PC & then printouts can be taken in a document format with report number, data & time.

View Complete Details

Multipara

pH, mv, ORP, Conductivity, TDS, Salinity, DO, Temperatures & ISEGLP Compliant

* MicroController Based* Multipoint Calibration* Automatic Temp. Compensation* Large Colored Graphic Display* Self Diagnostic Messages* PC connectivity* Inbuilt Battery Backup* Date/time stamped calibration report.

View Complete Details

Motorless Magnetic Stirrer

It is with a single platform having multiple stirring points for6 large flasks of 1 Litre (max - dia 125 mm)or 15 small vessels (max - dia 60 mm) Typical Application :Standardising the condition of dissolving a sample.The facility to read rotation speed and count down time is extremely useful. You can optimise and standardise a particular speed of rotation, time of stirring for a given weight of sample and volume of solvent, thereby ensuring complete and through dissolution of sample before analysis. Whirlmatic Mega magnetic stirrer is a Multipoint aesthetically designed, compact, ultraflat stirring system. The ultra flat design is ideally suited for manyoperations. Due to FRP housing the stirrer is completely corrosion resistant . The conventional stirrers use a magnet fixed to the motor for rotational force, whereas rotating electromagnetic field is used in motorless stirrers It has unique advantages - saving of space, silent and wear proof operation, smooth & reliable stirring speed. A special Soft - Start technique ensures un-attended operation. With Soft Start the stirring paddles always catch the centre to slow, gradual rise in speed till it attains the set level. Digital Indication of RPM & provision of timer to set desired time interval makes the stirrer extremely useful for standardization

View Complete Details

Linear Motion Shakers

Spectralab HM - series of Orbital and Linear Shakersare designed to mix liquids uniformly and thoroughly.They are also ideally suited for microbiological applications such as mixing at controlled slow and steady speed. Accepts variety of vesselssuch as conical flask, dishes, test tubes, bottles etc.Shakers with heating facility are also available.Variable speed - adjustmentthrough soft touch keys. These are sturdy & reliable. Usefulin chemical, Micro-Biological, Biotechnical etc.

Ideal for slow as well as high shaking operations with variable speed from 40 - 200rpm. Accepts conical flasks 18 nos. of 250 ml /12 nos. of 500ml or 9 nos. of 1000 ml. Two models are available.

Linear Motion Shaker Model RM 8

The Orbital Shaker has a facility to change the direction of rotation with programmed time interval.

View Complete Details

Orbital Shakers

Spectralab HM - series of Orbital and Linear Shakersare designed to mix liquids uniformly and thoroughly.They are also ideally suited for microbiological applications such as mixing at controlled slow and steady speed. Accepts variety of vesselssuch as conical flask, dishes, test tubes, bottles etc.Shakers with heating facility are also available.Variable speed - adjustmentthrough soft touch keys. These are sturdy & reliable. Usefulin chemical, Micro-Biological, Biotechnical etc.

View Complete Details

Water Bath Shaker

Suited for shakingalong with heating. This linear motion shaker is ideal for low & high speed from40 - 200 strokes/min. Microcontrollerbased design to indicate shaking speed, temp. and time withaudio alarm. Hinged SS lid with transparent window. Water bath features and specifications are same, as that of PB 28 L. Accepts conical flasks 12 nos. of 250ml or 8nos. of 500ml or 4 nos. of 1000 ml.

Specifications :

TempRange- 10C above ambient to 95 C(Using water)Temp. Accuracy - 0.2C ( Resolution 0.1C)Controller - Mocrocontroller with keyboard - LCD DisplayTimer - Upto 99 hours ( Audio Alaram after set time )Drive -Permanent MagnetDCMotorMovement -LinearSpeed - 40 - 200 strokes / minLevelcontrol - SS float switch with solenoid valveMOC. - SS- inner tank, outer MS powder coatedLid. -SS lid with transparent window Dimension - 74 x 44 x 31 cm, (Usable Volume : 50x37x23 cm)Power -230VAC / 50Hz, 1700 W

View Complete Details

Mini Cooling System

The solid state cooling system is based on peltier effect & can be used for applications such as viscosity bath & other small cooling application

These are basically miniature Thermoelectric Solid State Systems, designed on peltier effect. In many situations, need of analysis at subambient temperature arises. The lab chemist has to use either an elaborate and bulky compressor based cooling system or use ice. Both have their own disadvantages. These Systems are simple, sturdy & occupy very small bench space.No compressor no noise, no vibrations. No Ice, no mess.AllSolidStatedesign, no moving parts, virtually maintenance free.

These are suitable to carry out Titration at subambient or at elevatedtemperatures, to maintainCell Holder Temperature, viscosity measurement, to cool vials & test tubes etc.

Model MCS - 150

Fortitrations at sub ambient or at elevated temperatures :

In this case the titration beaker ( 55mm Dia) is inserted in the block which is kept at desired temp.

Application : Titrations for diazotisation , SAP value and pH Stat

View Complete Details

Kjeldahl Nitrogen Analyzer

Digestion Unit :

* Aluminium heating block with acid resistantS.S. rack & extraction hood.

Scrubber : * Environmental friendly scrubbing system toremove hazardous fumes. Distillation Unit :* Microcontroller based distillation system* Automatic addition of Alkali & Boric acid* Automatic steam processing* Automatic water addition in steam generator* Cleaning mode for acid & alkali pumps* Display of time with countdown for distillation

View Complete Details

Melting Point Model

GLP Compliant

* Melting & Boiling Point* Oil bath with stirring* Real time video display* Inbuilt RTC.* 10 x magnification on TFT.* Temperature upto 300C.* Time & Date stamped report.

View Complete Details
Tell Us What are you looking for? Will call you back