Our offered Product range includes 40-75V/3A 0-10V/0-5A, 20-70V/750mA BATTERY CHARGER CUM POWER SUPPLY, DUAL POWER SUPPLY FOR PURE AIR GENERATOR, CHARGE CONTROL UNIT, Battery Charger Cum Power Supply and SMPS Chargers.
TECHNICAL SPECIFICATIONS DUAL POWER SUPPLY FOR PURE AIR GENERATOR 1. Output Voltage (Pure sine wave) : 115V AC (98 124V AC)Current Rating : 6AmpsFrequency : 400Hz (380-420 Hz)Load type : Inductive 2. Output Voltage : 28V DC (18 30V DC)Current rating : 300mAmpsRipple : 3mV RMSShort circuit protection & Over load protection 3. Input Voltage : 230V AC (207 250V AC)Frequency : 50Hz (48 52Hz) 4. Indicators : AC Voltage, Current: DC Voltage, Current
SPECIFICATIONS 1) Input : 220V +10% 50Hz (AC line power) 2) Output : a) 40V to 75 DC Variableb) 0 to 10V DC Variablec) 20-70V DC Variable3) Output current : a) 0 to 3 Ampsb) 0 to 5 Ampsc) 0-750mA4) Digital display : 4 digit meters for measuring voltages and currents 5) Ripple : < 1% RMS at Battery 6) Efficiency : > 70%@ nominal input and outputat 100% load.7) Insulation resistance : > 2M ohm between the live point and the ground .8) The charger will be able to charge 24 cells of sealed lead acid batteries of 2V each with constant voltage and current limit to a maximum of 3Amps. 9) Discharge facility : Suitable load will be provided for discharging the battery 24 cells of2V each @ C/10 rate (25Ah Battery).This is in order to discharge the cells up to Cut-Off voltage of 1.70V prior to starting of recharge. 10) The battery charger will be provided with over voltage short circuit battery reversal and under voltage cut-off. 11) The charger will be provided with input on discharge ON indication. 12) The charger Input/Output will be terminated on Front Panel.