- MaterialCold rolled steel
- Overall Part Dimensions2” x 3”
- Volume50,000
- Material FinishZinc plated
he challenge was that these electrical connector covers were meant to be used to daisy chain cables inside of in-floor and under-floor electrical raceways in industrial settings, applications with strict size limitations. Their original electrical connector cover was a complex part. It consisted of three distinct surfaces: the cover, an L-shaped flag, and a U-cutout flag. This one part was made up of two separate metal stamped pieces — the cover and U-cutout flag was one piece, the L-shaped flag was the second. After being manufactured separately, the two pieces were welded together, a slow and expensive process. Part of the reason AFC employed this method was because not every job required a fully completed connector cover. Many jobs did, but others required only the cover and U-cutout flag, while still others required nothing but the L-shaped flag. AFC manufactured each piece separately for when they were required separately, and welded them together when the full connector cover was needed. Th