Our Product / Services
1.nominal voltage : 12v /24v/36v/48v dc
2. max. Charging current : 10a/20a/30a/ 40a/50a/75a/100a
3. deep discharge protection : 10.5v/21.0v
4. Over charge protection : 14.4v/28.8v
5. Restart of charging : 12.5v/25v
6. Reconnection of load : 12.5v/25v
7. Output load current : 10a max.
8. Battery ah rating : 100ah max.
9. Solar panel : 120watts max.
10. Operating temp. : 50c
11. Self consumption : 25ma
12. Protection : a)battery reverse protection
b)solar panel reverse protection
c)battery over charge protection
d)over load protection
13. indications : a)charging on solar
b)battery low
c)over load
d)16x2 lcd display to readreal timeand to set the loadonby offtime
We are the main manufacturers and wholesale suppliers of Dual Power Pure Air Generator from Telangana, India. We are appreciated in the market for offering a wide range of Dual Power Pure Air Generator in various specifications using best quality raw material, and having a longer service life. We have a team of professionals who carefully processes the Dual Power Pure Air Generator and tests it on a variety of parameters to ensure that they are pure and comply with the clients specifications. For the convenience of our clients, we package the Dual Power Pure Air Generator in safe packing boxes/bags and deliver within a short span of time. While the Dual Power Pure Air Generator is protected against short circuit & over load protection, its voltage is of 300m Amps.
Specification :
Input | |
---|---|
Voltage | 230V AC (207 – 250V AC) |
Frequency | 50Hz (48 – 52Hz) |
Output | |
Voltage (Pure sine wave) | 115V AC (98 – 124V AC) |
Frequency | 400Hz (380-420 Hz) |
Current Rating | 6 Amps |
Load Type | Inductive |
Voltage | 28V DC (18 – 30V DC) |
Current Rating | 300m Amps |
Ripple | 3mV RMS |
Protection | Short circuit protection & Over load protection |
Indication | AC Voltage, Current DC Voltage, Current |
Battery Charger Cum Power Supply
Specification :
Input : | 220V +10% 50Hz (AC line power) |
Output : | 40V to 75 DC Variable 0 to 10V DC Variable 20-70V DC Variable |
Output current : | 0 to 3 Amps 0 to 7 Amps 0 to 750mA Amps |
Digital display : | 4½ digit meters for measuring voltages and currents |
Ripple : | < 1% RMS at Battery |
Efficiency : | >70% @ nominal input and out put at 100% load |
Insulation resistance : | > 2M ohm between the live point and the ground |
Charging : | The charger will be able to charge 24 cells of sealed lead acid batteries of 2V each with constant voltage and current limit to a maximum of 3Amps. |
Discharge facility : | Suitable load will be provided for discharging the battery 24 cells of 2V each @ C/10 rate (25Ah Battery). This is in order to discharge the cells up to Cut-Off voltage of 1.70V prior to starting of recharge. |
Protection : | Battery Reverse Protection Under voltage cut off Battery Over charge Protection Over Load Protection Short Circuit Protection |
Indications : | Discharge ON Input ON The charger Input/Output will be terminated on Front Panel. |