Post Buy Requirement
AB
Chennai, Tamil Nadu, India
Add Review

UPS #5767455

Solar Ups

  • Battery 2 Battery System
  • Input DC Range 21 ~ 28.4
  • Efficiency(on battery mode) > 90%
  • Protections Overload 120%
  • Short - Circuit 300%
  • Charger Current 9.5 A
  • Warranty 2 Years
View Complete Details

Line Interactive Ups

  • AVR 145~300V AC
  • Battery 12V, 7.2AH / 7AH
  • Back-Up (Typical 1 PC) 10~20min. Approx
  • Warranty 2 Years on UPS Electronics 1 Year on Battery
View Complete Details

Online UPS

Features :
  • High frequency and double conversion online technology
  • High end Micro Controller Based
  • Wide Input voltage range
  • Advanced PFC Technology
  • Advanced Battery Management
  • Automatic Battery Charging in UPS off mode
  • Short Circuit and overload protection
  • EMI / RFI noise filter
  • Smart RS232 Communication with monitoring software
  • SNMP card slot (optional)
  • LCD/LED Display simultaneously
  • Specially designed to suit Indian power and environment conditions
  • Generator Compatible
  • Isolation Transformer (Optional)
  • Over Temperature Protection.
  • Different output Voltage settings.
  • Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.
  • Static Bypass Enable or Disable.
  • Outlets Programmable and non programmable.
  • Protection from DC Fan failure.

 
Technical Specifications  
   
Model NM36MX1KK11 1KVA/800W  
Capacity   1KVA / 800W
Input Voltage Range When load < 50%, range is 118 ± 5VAC~295
When ± 50% load, input range is 160 ± 5VAC~295 ± 5VAC
Frequency 46~54Hz ± 0.5Hz
Phase Single Phase
Input Power Factor ≥0.95
Output Voltage 208/220/230/240V AC
Frequency Range 50Hz ± 0.2%
THD (Liner Load) <3%
THD (Non-Liner Load) <5%
Overload Capability >110% 30s turn to bypass mode;
>150%, 200ms turn to bypass
Crest Factor 3:1 (max)
Shot Circuit Protection 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode), 5 cycles turn off inverter, provide alarm (battery mode), input fuse blown or breaker action
Waveform Pure Sine Wave
Transfer time AC to bypass mode 4ms (typical 2.5ms)
Efficiency ≥ 85%~92%
Battery DC Voltage 36VDC
Charge Current 0.7A ~ 08A
Communication Interface Battery Backup (Sound beeping) RS232; SNMP (optional)
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of UPS from Chennai, Tamil Nadu by Agnes Batteries
Post Buy Requirement
AB
Chennai, Tamil Nadu, India
Add Review

UPS #5767455

Solar Ups

  • Battery 2 Battery System
  • Input DC Range 21 ~ 28.4
  • Efficiency(on battery mode) > 90%
  • Protections Overload 120%
  • Short - Circuit 300%
  • Charger Current 9.5 A
  • Warranty 2 Years
View Complete Details

Line Interactive Ups

  • AVR 145~300V AC
  • Battery 12V, 7.2AH / 7AH
  • Back-Up (Typical 1 PC) 10~20min. Approx
  • Warranty 2 Years on UPS Electronics 1 Year on Battery
View Complete Details

Online UPS

Features :
  • High frequency and double conversion online technology
  • High end Micro Controller Based
  • Wide Input voltage range
  • Advanced PFC Technology
  • Advanced Battery Management
  • Automatic Battery Charging in UPS off mode
  • Short Circuit and overload protection
  • EMI / RFI noise filter
  • Smart RS232 Communication with monitoring software
  • SNMP card slot (optional)
  • LCD/LED Display simultaneously
  • Specially designed to suit Indian power and environment conditions
  • Generator Compatible
  • Isolation Transformer (Optional)
  • Over Temperature Protection.
  • Different output Voltage settings.
  • Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.
  • Static Bypass Enable or Disable.
  • Outlets Programmable and non programmable.
  • Protection from DC Fan failure.

 
Technical Specifications  
   
Model NM36MX1KK11 1KVA/800W  
Capacity   1KVA / 800W
Input Voltage Range When load < 50%, range is 118 ± 5VAC~295
When ± 50% load, input range is 160 ± 5VAC~295 ± 5VAC
Frequency 46~54Hz ± 0.5Hz
Phase Single Phase
Input Power Factor ≥0.95
Output Voltage 208/220/230/240V AC
Frequency Range 50Hz ± 0.2%
THD (Liner Load) <3%
THD (Non-Liner Load) <5%
Overload Capability >110% 30s turn to bypass mode;
>150%, 200ms turn to bypass
Crest Factor 3:1 (max)
Shot Circuit Protection 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode), 5 cycles turn off inverter, provide alarm (battery mode), input fuse blown or breaker action
Waveform Pure Sine Wave
Transfer time AC to bypass mode 4ms (typical 2.5ms)
Efficiency ≥ 85%~92%
Battery DC Voltage 36VDC
Charge Current 0.7A ~ 08A
Communication Interface Battery Backup (Sound beeping) RS232; SNMP (optional)
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us