Post Buy Requirement
AE
Bangalore, Karnataka, India
Verified Add Review

Transformers

Current Transformer

  • System Voltage Upto 1.1kV
  • Usage Suitable For Metering & Relaying application in AC Power Systems.
  • Frequency 50Hz To 400Hz
  • Secondary Current 1A, 5A, 0.577A
  • Primary Current 1A To 75, 000A
  • Burden (VA) 1, 1.25, 1.5, 2.5, 3.75, 5, 7.5, 10, 12.5, 15, 20VA
  • Accuracy Class Metering: 0.2, 0.2s, 0.5, 0.5s, 1, 3 & 5
  • Protection 5P10, 5P20, 10P10, 10P20
  • Special Protection (PS) Knee Point Voltage(Vk) & Magnetizing Current (Im) as Per Requirement
  • Ambient Temperature - 50 C to + 450 C
  • Thermal Short Circuit Current (Ith) 60 x Ip / 1 Sec
  • Instrument Security Factor (ISF) 2.5, 5, 10
  • Thermal Insulation Class Class A, Class B &Class F
  • Type / Encapsulation Resin Cast, Moulded Case & Tape Insulated
  • Construction Window type (Ring & Rectangular), Wound Primary Type & Bar Primary Type
  • Applicable Standard IS 2705 Part (1, 2 & 3), IEC 61869 Part (1 & 2)
View Complete Details

LV Voltage Transformer

  • Usage Suitable for Metering & Relaying application in AC Power Systems.
  • Input Voltage Up to 1.1kV
  • Frequency 50Hz To 400Hz
  • Phase Single Phase & Three Phase
  • Accuracy Class Metering : 0.2, 0.5, 1 Protection : 3P, 6P& 5PR (Residual Protection)
  • Service Indoor
  • VT Ratio 110V/110V, 110V/RT3//110V/RT3, 110V//110V/RT3, 110V/RT3//110V, 415V/110V, 415V/110V/RT3, 415V/RT3//110V/RT3
  • Burden Upto 100VA
  • System Earthing Earthed/ Unearthed
  • Ambient Temperature -50 C To +450 C
  • Applicable Standard IS 3156 Part (1, 2 &3 ) , IEC 61869 Part (1 & 3)
  • Thermal Insulation Class Class A, Class B & Class F
  • Type / Encapsulation Resin Cast & Vacuum Pressure Impregnated (VPI)
View Complete Details

LT DRY TYPE TRANSFORMER

  • Application Power, Control Devices & Utilities For both Indoor Purpose.
  • Frequency 50Hz to 400Hz
  • Capacity Up To 250kVA
  • Enclosure IP21, IP23, IP32,
  • System Voltage Up to 1.1kV
  • No. Of Phase Single Phase, Three Phase& Three Phase to Single Phase
  • Vector Group As Required By Customer
  • Type Of Insulation Vacuum Pressure Impregnated (VPI) Or Resin Cast
  • Thermal Insulation Class Class A, Class B, Class F, Class H & Class C
  • Ambient Temperature -50 C to +450 C
  • Reference Standard IS12290, IS6297, IS12021, IS2026, IS11171 & IS1180
View Complete Details

Ring Type Current Transformer

250 /Piece Get Latest Price
  • Phase Single Phase
  • Rated Power (VA) upto 30VA
  • Rated Voltage 415V
  • CT Ratio up to 75000 A
  • Accuracy Class 0.2, 0.5, 1 or 3, 0.2s, 0.5s, 5P10, 5P20, PS
  • Rated Power up to 30VA
  • System Voltage upto 1.1kv
  • ILV 0.66/3kV
  • Type of Insulation Tape Insulated
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Jaiprathish (AMPTURN ELECTRICALS LLP)
  • No.7/2, Site No. 31 Kachohalli Industrial Area, Bengaluru-562123, Karnataka, India, Magadi Road, Bangalore
  • Share us via
  • Call 08069182252 Ext. 004
Manufacturer of Transformers from Bangalore, Karnataka by AMPTURN ELECTRICALS LLP
Post Buy Requirement
AE
Bangalore, Karnataka, India
Verified Add Review

Transformers #7544803

Current Transformer

  • System Voltage Upto 1.1kV
  • Usage Suitable For Metering & Relaying application in AC Power Systems.
  • Frequency 50Hz To 400Hz
  • Secondary Current 1A, 5A, 0.577A
  • Primary Current 1A To 75, 000A
  • Burden (VA) 1, 1.25, 1.5, 2.5, 3.75, 5, 7.5, 10, 12.5, 15, 20VA
  • Accuracy Class Metering: 0.2, 0.2s, 0.5, 0.5s, 1, 3 & 5
  • Protection 5P10, 5P20, 10P10, 10P20
  • Special Protection (PS) Knee Point Voltage(Vk) & Magnetizing Current (Im) as Per Requirement
  • Ambient Temperature - 50 C to + 450 C
  • Thermal Short Circuit Current (Ith) 60 x Ip / 1 Sec
  • Instrument Security Factor (ISF) 2.5, 5, 10
  • Thermal Insulation Class Class A, Class B &Class F
  • Type / Encapsulation Resin Cast, Moulded Case & Tape Insulated
  • Construction Window type (Ring & Rectangular), Wound Primary Type & Bar Primary Type
  • Applicable Standard IS 2705 Part (1, 2 & 3), IEC 61869 Part (1 & 2)
View Complete Details

LV Voltage Transformer

  • Usage Suitable for Metering & Relaying application in AC Power Systems.
  • Input Voltage Up to 1.1kV
  • Frequency 50Hz To 400Hz
  • Phase Single Phase & Three Phase
  • Accuracy Class Metering : 0.2, 0.5, 1 Protection : 3P, 6P& 5PR (Residual Protection)
  • Service Indoor
  • VT Ratio 110V/110V, 110V/RT3//110V/RT3, 110V//110V/RT3, 110V/RT3//110V, 415V/110V, 415V/110V/RT3, 415V/RT3//110V/RT3
  • Burden Upto 100VA
  • System Earthing Earthed/ Unearthed
  • Ambient Temperature -50 C To +450 C
  • Applicable Standard IS 3156 Part (1, 2 &3 ) , IEC 61869 Part (1 & 3)
  • Thermal Insulation Class Class A, Class B & Class F
  • Type / Encapsulation Resin Cast & Vacuum Pressure Impregnated (VPI)
View Complete Details

LT DRY TYPE TRANSFORMER

  • Application Power, Control Devices & Utilities For both Indoor Purpose.
  • Frequency 50Hz to 400Hz
  • Capacity Up To 250kVA
  • Enclosure IP21, IP23, IP32,
  • System Voltage Up to 1.1kV
  • No. Of Phase Single Phase, Three Phase& Three Phase to Single Phase
  • Vector Group As Required By Customer
  • Type Of Insulation Vacuum Pressure Impregnated (VPI) Or Resin Cast
  • Thermal Insulation Class Class A, Class B, Class F, Class H & Class C
  • Ambient Temperature -50 C to +450 C
  • Reference Standard IS12290, IS6297, IS12021, IS2026, IS11171 & IS1180
View Complete Details

Ring Type Current Transformer

250 /Piece Get Latest Price
  • Phase Single Phase
  • Rated Power (VA) upto 30VA
  • Rated Voltage 415V
  • CT Ratio up to 75000 A
  • Accuracy Class 0.2, 0.5, 1 or 3, 0.2s, 0.5s, 5P10, 5P20, PS
  • Rated Power up to 30VA
  • System Voltage upto 1.1kv
  • ILV 0.66/3kV
  • Type of Insulation Tape Insulated
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Jaiprathish (AMPTURN ELECTRICALS LLP)
  • No.7/2, Site No. 31 Kachohalli Industrial Area, Bengaluru-562123, Karnataka, India, Magadi Road, Bangalore
  • Share us via
  • Call 08069182252 Ext. 004