My ExportersIndia

For Buyer

For Seller

For Help

Calibrators

We offer the best product range of Universal Calibrator and UNIVERSAL CALIBRATORS AND SIMULATORS.

Universal Calibrator

Analogik universal calibrator is very useful tool to calibrate many types of process control instruments which accepts mV and mA and resistance. The universal calibrator is designed to give highest stability and accuracy. The calibrator can be used for lab or inhouse purpose as well as to used on field. This is very useful tool for calibration of instruments, commissioning, quality assurance and fault findings.
View Complete Details

UNIVERSAL CALIBRATORS AND SIMULATORS

  • FUNCTIONS mV, mA Resistance source mV, mA Read
  • RANGES 0 to 200 mV 0 to 25 mA 0 to 500V
  • INDICATION 4 1/2 digit LCD / LED - Green mV, mA and V or °C
  • POWER SUPPLY 230V AC, SOHz for table top model 2 Batteries of 9 VDC for portable model
  • RESOLUTION 10 uVformV 0.01 mA 0.1 V or 0.1 °C
  • ACCURACY 0.1 % of FS 0.15% of FSformA 0.2 % of FS for RTD
  • OPERATIONGTEMP & HUMIDITY 10to50°C, 90%Rhmax
  • BATTERY LIFE 6 hrs. incase of full o/p currect 30 hrs. when no o/p current 90
  • SIZE WEIGHT 90 (H) x 215 (W) x 230 (D) mm 2 kg (Table Top) 1 kg (Portable)
INTRODUCTION
Analogik universal calibrator is very useful tool to calibrate many types of process control instruments which accepts mV and mA and resistance. The universal calibrator is designed to give highest stability and accuracy. The calibrator can be used for lab or inhouse purpose as well as to used on field. This is very useful tool for calibration of instruments, commissioning, quality assurance and fault findings.
Features
Green display 1/2" height.
High accuracy & reliability.
Easy to operate.
FUNCTIONAL DESCRIPTION
Power on switch - Powers the instruments with indication.
Coarse & Fine Pot - Both the potentiometers are multiturn helipots & used to adjust the correct value on display.
Res. Adjust Pot - Mult! turn Helipot to adjust the correct value of resistance.
Read / Source Switch - Push to ON switch. When in press condition parameters will be in READ mode when unpress mV / mA in source mode.
mV / mA switch - This switch selects the parameter mV or mA either read or source.
RTD Switch - When this switch is pressed display shows temp, in C and as per resistance chart (DIN - 43760) corresponding resistance will be source when switch is relased.
When switch is in press condition output at R and B/C terminals is in open (infinity resistance) mode.
Display - Green, 1/2" height, common to read all the parameters

CALIBRATION EQUIPMENTS
mV / mA Source
RTD Simulators
mV Source
pH Simulator
Conductivity Simulator
RTD Simulator with Indication
Portable Thermocouple Calibrator
Loop Analyser

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us