Our Products
APPLICATION
cable clips are devices that are used to manage cables and wires by securing them to a surface such as a floor, wall or ceiling.They are used by engineering and industrial companies to manage the many cable associated with the machinery they use on a daily basis.cable clips are also used in homes to ensure that cables used in home entertainment systems such as televisions, sound systems and gaming systems remain unobtrusive.They come in many different shapes and sizes to accommodate almost any number of cables of any size.
ITEM NO. | H (MM) | CIRCLE PATH ‘D’
(MM) |
NAIL |
JC – 3 MM | 3.6 | 3 | 1.4 X 15 |
JC – 3.5 MM | 4.2 | 3.5 | 1.47 X 14 |
JC – 4 MM | 5.3 | 4 | 1.7 X 14 |
JC – 5 MM | 6 | 5 | 1.7 X 14 |
JC – 6 MM | 8 | 6 | 1.82 X 16 |
JC – 7 MM | 8.7 | 7 | 1.82 X 18 |
JC – 8 MM | 9.5 | 8 | 1.95 X 19 |
JC – 9 MM | 11 | 9 | 2.05 X 22 |
JC – 10 MM | 12 | 10 | 2.1.X 23 |
JC – 12 MM | 13.5 | 12 | 2.2. X 25 |
JC – 14 MM | 16.5 | 14 | 2.3 X 30 |
JC – 16 MM | 18 | 16 | 2.35 X 32 |
JC – 17 MM | 20 | 17 | 2.6 X 38 |
JC – 18 MM | 20.5 | 18 | 2.6 X 38 |
JC – 20 MM | 22.5 | 20 | 2.7.X 40 |
JC – 22 MM | 23.5 | 22 | 2.9 X 43 |
JC – 25 MM | 26.5 | 25 | 3.1 X 50 |
JC – 30 MM | 32.5 | 30 | 3.5 X55 |
JC – 32 MM | 34.5 | 32 | 3.5 X 55 |
JC – 35 MM | 38 | 35 | 3.5 X 60 |
JC – 40 MM | 43.8 | 40 | 3.5 X 65 |
ApplicationThese modern, low priced, compact, sturdy & handy instrument is being used to cool down overheated parts in innumerable Engineering fields. Our fans use latest technique in manufacturing & design technology, to ensure highest reliability & trouble free performance. Some of the application area are :
Stainless Steel Ties have superior and high tensile strength and is made from corrosion resistant stainless steel grade 304. The unique and self locking mechanism gives easy and hassle free security in locking.
The stainless steel ties are a quick, efficient and ultimate way of securing cables in extreme conditions and hazardous areas. Used both in indoor and outdoor areas such as the Petrochemical, Ship building, Power Stations, Food Processing Industries, Mining, Offshore and other aggressive environments
Ensuring a long service life, these ties are Water, Chemical, UV radiation resistant and Non Flammable.
Just one operation is required for both tying and identifying bundles of cables.
They can also be used to identify pipes and other components.
Tag marking is carried out by hot foil printing done by us or you may use a permanent marker pen.
Standard colour :Natural Colour or UV Weather Resistant Black. Other colours available on request, subject to a Minimum Order Quantity.
Operating Temperatures :
-25C to +85C
Standard Packing :100 Nos.
Tensile Strength :High Tensile strength provides a secure locking which will not slip, come off, or slacken. Must be cut to be removed.
Material :Manufactured from UL approved Nylon 606 material.
Flammability Rating :
Ul V -2 Resistant to Fungus, corrosion, and most mild acids.
This series indicator light ( pilot light) are used as indicating, accidental signals and other pilot signal of instrument circuit in the areas of electric power, telecommunication, machinery, marine, textile, printing, mining etc
panel mount indicator lights
1 long service life2 low consumption3 good reliability4 Fast and easy to install5 Mounting size: diam 22mm6 Color: red, green, yellow, white, blue
APPLICATIONS
Industrial plugs and sockets are reliable, robust, easy to wire and provide outstanding resistance to weathering and to chemicals. All of which accurate safe operation, even in the most advanced environmental conditions.
Field of use | IP44 | IP67 |
Agriculture | Mobile or portable equipment or appliances used or stored on sheltered premises. | Outdoor installation of pumping, ventilation, drying equipment. |
Chemical Industry | Indoor on premises for storage and maintenance purposes where connections are not exposed to the risk of immersion or chemicals. | On premises without risk of explosions but where the connections are exposed to chemicals and subject to possible immersion. |
Construction sites and shipyards | On covered construction sites sheltered against weathering the exposed to splashing with water. | On outdoor construction sites where the connections are left on damp ground exposed to freezing, dust and weathering. |
Sports complexes and other places of public entertainment , TV and film studios. | On sheltered premises protected against the weather, though exposed to splashing, without high connected loads. | Outdoor connections exposed to rain, snow, mud, freezing and other critical weather conditions. |
Food Industry | In sheltered locations, on indoor premises used for storage and maintenance. | In location subject to washing by hosing down and where connections are subject to heavy duty. |
Heavy Industry | In sheltered store-houses, workshops for maintenance, minor assembly and moulding. | In rolling mills, foundries, blast furnaces, etc., where the connections are exposed to dust, metallic shavings, coolants and are subject vibrations and impact. |
Light Industry | Locations without high humidity or ambient pollution serving for assembly, moulding maintenance and storage. | On premises subject to cleaning by means of chemical solvents. Also where heavy loads require high safety in connections. |
Installations for EDP centers | Electrical connections executed above floor level. | Electrical connections executed under raised floors with risk of immersion. Where heavy loads require high safety in connections |
Ports | In sheltered locations such as docks, repair shops, offices, etc. | Quays, docks, piers, etc. where there is risk of high waves partial flooding. |
Airports | In sheltered locations, hangers, repair shops, store houses. | Outdoors for connection between mobile or portable appliances and aircraft. |
Water treatment plants | Indoor use in repair shops, etc. | In all locations with risk of flooding and for outdoor use with pumps, aeration and ventilation systems. |
Application: Used in normal climatic condition for armored & unarmoured cables.
Material : | Brass (IS-319) Standard (Al. / S.S. / M.S. also available) |
Plating : | Nickle Plated Standard (Chrome also available) |
Entry Threads : | BSC Standard (PG / Metric / NPT / BSP / also available) |
Sealing Rubber Ring : | Nitrile / Neoprene |
Gland Standard : | BS 6121 |
Ingress Protection : | IP 66 as per IS 12063 |
Test Certi. No. | CIMFR/TC/P/1396 Dt:13/01/2015 |
Series | MCW
MAKE- M.C.I ( METAL CRAFT INDUSTRIES) |
Application:
Flame Proof Double Compression Glands are generally used in flammable gas / vapours area (for gas group I, IIA & IIB) as well as in normal climatic conditions also which are weather proof, water proof and dust proof (IP-66) which can be used in Hazardous climatic condition. Also when protected by PVC shrouds it can be used in corrosive atmosphere.
These glands are available in different sizes and are suitable for all cables upto 1000 sq. mm. and control cables upto 61 cores.
Accessories:
PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available with specified dimensions in accordance to the Gland separately.
Fitting Sequence:
(a) Insert Part No. 9, 8 & 7 respectively on the Outer Sheath of the cable before exposing the Armour.
(b) After removing Outer Sheath of the cable, Insert Part No. 6 over the Exposed Armour.
(c) Size Armour length, Lift Armour & Insert Part No. 5 under the Armour, Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No. 6 towards it.
(d) Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part No. 7 & Tight Part No. 9 with Part No. 7.
(e) Finally apply the full fitted Gland in the Enclosure with the entry thread provided, if the Enclosure does not have threaded entry than tight the Gland with the Part No. 1 provided.
Application:
Flame Proof Double Compression Glands are generally used in hydrogen gas/vapours area (for gas group IIC) as well as in normal climatic conditions also which are weather proof, water proof and dust proof (IP-66) which can be used in Hazardous climatic condition. Also when protected by PVC shrouds it can be used in corrosive atmosphere.
These glands are available in different sizes and are suitable for all cables upto 1000 sq. mm. and control cables upto 61 cores.
Accessories:
PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available with specified dimensions in accordance to the Gland separately.
Fitting Sequence:
(a) Insert Part No. 10, 9, 8 & 7 respectively on the Outer Sheath of the cable before exposing the Armour.
(b) After removing Outer Sheath of the cable, Insert Part No. 6 over the Exposed Armour.
(c) Size Armour length, Lift Armour & Insert Part No. 5 under the Armour, Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No. 6 towards it.
(d) Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part No. 7 & Tight Part No. 10 with Part No. 7.
(e) Finally apply the full fitted Gland in the Enclosure with the entry thread provided, if the Enclosure does not have thread than tight the Gland with the Part No. 1 provided.
Bimetallic Sheetconsists of Copper(Sheet metal) cladded on pure Aluminum(Base metal), both metal being diffused together to form an inseparable whole by rolling bonding process. Bimetal, is therefore not an alloy and copper layers are not electro Plating but are rather mechanically welded Aluminum Sheets, Bi-metal sheet, bimetal sheet.
Applications:
Gong Bellsworking on 220/250 volts, Single Phase, Conventionally called as Cinema Bell. Aluminium Cast Body, Dust & Weather Proof is widely used in Cinemas, Hotels, Restaurants, Ships, Workshops, Banks, Houses, Colleges, Schools etc. This Bell is provided with a Chromium mild-steel pressed gong-in order to ensure long durability. It can be easily mounted on the wall with two nails.
Features
Ratchet mechanism
Professional crimping tool for reliable performance Ergonomic handles for low effort indent crimping Ratchet action ensures full crimp cycle with safety release Minimum set of 80, 000 cycles.
PVC Marker TubesMaterial: Made from premium Heavy Metals free RO HS compliant PVC compound developed In-house.
WIDELY USED FOR PRINTING MARKERS ON ALL TYPES OF FERRULE PRINTING MACHINES OF REPUTED MAKES