Post Buy Requirement
AH
Mumbai, Maharashtra, India
Add Review

Other Products / Services #5726590

In Air Compressors

In air compressors, increase in pressure of air leads to the increase of the air temperature also. Apollo offers air cooled heat exchanger in aluminum construction to cool the compressed air close to the ambient temperature with minimum pressure drop.

Inter cooler & After Cooler are compact aluminum brazed heat exchangers that cool the compressed air at different stages. Heat Exchanger Spares of reciprocating compressors are also available for all popular brands.

APPLICATION
Multistage Reciprocating Air Compressor

SPECIFICATION
Design Temperature: Maximum 180 C.Design Pressure: Maximum 15 bar.

View Complete Details

Aluminium Radiator

Radiator is used to cool engine coolant (jacket water) & maintain temperature of coolant within limits. Apollo is one of the most reliable radiator manufacturers that offers two types of radiator:

All aluminum radiator & Copper tube
Aluminum fin design to OEM and end users.

APPLICATION
Diesel EngineReciprocating Air CompressorConstruction machinery ( Excavators , Vibratory Soil Compactor etc)

SPECIFICATION
Design Temperature: Maximum 120 C.Design Pressure: Maximum 4 bar.

View Complete Details

Evaporator

Apollo has designed heat exchangers for Refrigerated Air Dryers to dry the compressed air. Apollo has designed 4 models of CPNR for compressor capacity of:

  • 100 CFM
  • 200 CFM
  • 300 CFM
  • 1000 CFM

These can be cascaded together in parallel for higher capacity compressors. e.g Six units each of 1000 CFM capacity heat exchangers together can be used for a compressor of 6000 CFM

This Heat exchanger works on the Principle of Air Cooled Condenser. In first stage, compressed air is cooled to 20 C. It is then passed through a second heat exchanger where it is further cooled to 2-3 C by exchanging heat with a refrigerant. Now, water vapour gets condensed & is separated and collected in moisture separator. The cooled air remains saturated at high pressure & low temperature of 2-3 C corresponding to -60 C dew point. The cooled air exchanges heat with incoming air in the first stage and thus gets reheated to almost room temperature; now the air is dry with low dew point of -60 C. This is also Known as Air Dryer Cooler.

APPLICATION
Refrigerated Air Dryers

SPECIFICATION
CFM : 100 , 200 , 300 , 1000Pressure Dew Point: 4 C.Design Pressure : Up to 20 bar

View Complete Details
Tell Us What are you looking for? Will call you back