Our offered Product range includes ORTHOPANTOMOGRAPHY X-RAY SYSTEMS (OPG), Dental X-ray Unit and Portable X-ray Machine.

ORTHOPANTOMOGRAPHY X-RAY SYSTEMS (OPG)

  • Generator Microcontroller based, full wave rectified
  • X-Ray Tube 0.5mm x 0.5mm fine focus
  • Anode Voltage 50 to 85 kV. (steps of 5 kV.)
  • Anode Current 12 mA.
  • Exposure Time OPG – 14 sec. CEPH – 4 to 50 mAS.
  • Film Size OPG – 6” x 12” / 10” x 12” CEPH - 8” x 10”
  • Cassette OPG - Straight/CR CEPH- Straight/CR
  • Magnification OPG – 1.2 CEPH - 1.1
  • Line Voltage 230 Volts+ 10%
  • Line Current 15Amp., Single phase
  • Space required   H                     W              D 7ft6”                 6ft             3ft
Generator Microcontroller based, full wave rectified
X-Ray Tube 0.5mm x 0.5mm fine focus
Anode Voltage 50 to 85 kV. (steps of 5 kV.)
Anode Current 12 mA.
Exposure Time OPG 14 sec.CEPH 4 to 50 mAS.
Film Size OPG 6 x 12 / 10 x 12CEPH - 8 x 10
Cassette OPG - Straight/CRCEPH- Straight/CR
Magnification OPG 1.2CEPH - 1.1
Line Voltage 230 Volts+ 10%
Line Current 15Amp., Single phase
Space required H W D7ft6 6ft 3ft

Generator Microcontroller based, full wave rectified
X-Ray Tube 0.5mm x 0.5mm fine focus
Anode Voltage 50 to 85 kV. (steps of 5 kV.)
Anode Current 12 mA.
Exposure Time OPG – 14 sec.
CEPH – 4 to 50 mAS.
Film Size OPG – 6” x 12” / 10” x 12”
CEPH - 8” x 10”
Cassette OPG - Straight/CR
CEPH- Straight/CR
Magnification OPG – 1.2
CEPH - 1.1
Line Voltage 230 Volts+ 10%
Line Current 15Amp., Single phase
Space required   H                     W              D
7ft6”                 6ft             3ft





View Complete Details

Dental X-ray Unit

  • X-Ray output 70 KV – 10mA
  • X-Ray Tube 0.5 mm focus Imported Tube
  • Radiation Leakage < 0.25 mG/hr. from focal spot
  • Voltage Compensation 190v to 250v built in digital controlled voltage stabilizer
  • Power Requirement 230v, 50Hz, 5Amp.
  • Radiography Cones Short Cone Long Cone (Optional)
X-Ray output 70 KV 10mA
X-Ray Tube 0.5 mm focus Imported Tube
Radiation Leakage < 0.25 mG/hr. from focal spot
Voltage Compensation 190v to 250v built in digital controlled voltage stabilizer
Power Requirement 230v, 50Hz, 5Amp.
Radiography Cones Short ConeLong Cone (Optional)

X-Ray output 70 KV – 10mA
X-Ray Tube 0.5 mm focus Imported Tube
Radiation Leakage < 0.25 mG/hr. from focal spot
Voltage Compensation 190v to 250v built in digital controlled voltage stabilizer
Power Requirement 230v, 50Hz, 5Amp.
Radiography Cones Short Cone
Long Cone (Optional)