Our Products
We are leaders in the market for providing best range of TRIO-TM 50 to 60 kW ABB String Inverter, PVS 50kw to 60 Kw ABB String Inverter, 10 To 12.5 kW ABB String Inverter, Luminous Solar Inverters and 100kw To 120kw ABB String Inverters
The TRIO-TM-50.0/60.0 is ABB’s latest three-phase string solution for cost efficient large decentralized photovoltaic systems for both commercial and utilityapplications.
This new addition to the TRIO family, with 3 independent MPPT and power ratings of up to 60 kW (480 V version), has been designed with the objective to maximize the ROI in large systems with all the advantages of a decentralized configuration for both rooftop and ground-mounted installations.
Modular designThe TRIO-TM-50.0/60.0 has a modular design to guarantee maximum flexibility, thanks to the different versions available.
The separate and configurable AC and DC compartments increase the ease of installation and maintenance with their ability to remain separately wired from the inverter module inside the system. The TRIO comes with the most complete wiring box configurations available including up to 15 DC inputs with fast connectors, string protection fuses, AC and DC switches and type II AC and DC surge arresters.
Design flexibilityThe double stage conversion topology offers the advantage of a wide input voltage range for maximum flexibility of system design. The TRIO-TM comes with a forced air cooling system, used also in the previous TRIO products, designed for a simple and fast maintenance, allowing a maximum flexibility of plant design. The inverter comes with mounting supports for both horizontal and vertical installations, which allow for the best use of space available beneath the solar panels.Embedded multi communication interfaces (WLAN, Ethernet, RS485) combined with a Sunspec compliant Modbus protocol (RTU/TCP) allow the inverter to be easily integrated with any third party monitoring and control systems.
Improved commissioning and maintenance Thanks to the build-in Web User Interface (WUI) the installer can commission the inverter wirelessly and change advanced parameters by using any standard WLAN enabled device (smartphone, tablet or PC). Integrated logging capability allows remote monitoring of the plant without the need of any additional external loggers. Remote firmware update of the inverter system andcomponents via Aurora Vision®.
Highlights
Technical Data And Types
| Type code | TRIO-5.8-TL-OUTD | TRIO-7.5-TL-OUTD |
|---|---|---|
| Input side | ||
| Absolute maximum DC input voltage (Vmax,abs) | 1000 V | |
| Start-up DC input voltage (Vstart) | 420...700 V (Default 420 V) | 420...700 V (Default 500 V) |
| Operating DC input voltage range (Vdcmin...Vdcmax) | 0,7xVstart ...950 V (min 300 V) | 0,7xVstart ...950 V (min 360 V) |
| Rated DC input voltage (Vdcr) | 610 Vdc | 720 Vdc |
| Rated DC input power (Pdcr) | 52000 W | 61800 W |
| Number of independent MPPT | 1 | |
| MPPT input DC voltage range (VMPPTmin ... VMPPTmax) at Pacr | 480-800 Vdc | 570-800 Vdc |
| Maximum DC input power for each MPPT (PMPPTmax) | 108 A | |
| Maximum input short circuit current for each MPPT | 160 A | |
| Number of DC input pairs | 12 (-SX/-SY), 16 (-SX) | 16 (-SX) |
| DC connection type | PV quick fit connector 3) on -SX and -SY version / Screw terminal block on Standard and -S version | |
| Input protection | ||
| Reverse polarity protection | Yes, from limited current source | |
| Input over voltage protection for each MPPT - varistor | Yes, 2 | |
| Input over voltage protection for each MPPT - plug In modular surge arrester |
Type 2 (-SX version) / Type 1+2 (-SY version) | |
| Photovoltaic array isolation control | According to local standard | |
| DC switch rating for each MPPT (version with DC switch) | 200 A / 1000 V | |
| Fuse rating (version with fuses) | 15 A / 1000 V | |
| Output side | ||
| AC grid connection type | Three-phase (3W+PE or 4W+PE) | |
| Rated AC power (Pacr @cosφ=1 ) | 50000 W | 60000 W |
| Maximum AC output power (Pacmax @cosφ=1) | 50000 W | 60000 W |
| Maximum apparent power (Smax) | 50000 VA | 60000 VA |
| Rated AC grid voltage (Vac,r) | 400 V | 480 V |
| AC voltage range | 320...480 V 1) | 384...571 V 1) |
| Maximum AC output current (Iac,max) | 77 A | |
| Contributory fault current | 92 A | |
| Rated output frequency (fr) | 50 Hz / 60 Hz | |
| Output frequency range (fmin...fmax) | 47...53 Hz / 57…63 Hz 2) | |
| Nominal power factor and adjustable range | > 0.995; 0...1 inductive/capacitive with maximum Smax | |
| Total current harmonic distortion | <3% | |
| Maximum AC cable section allowed | 95 mm2 copper (with TRIO-ALUMINUM-KIT 150 mm2 aluminum) | |
| AC connection type | Screw terminal block, cable gland PG42 | |
| Output protection | ||
| Anti-islanding protection | According to local standard | |
| Maximum external AC overcurrent protection | 100 A | |
| Output overvoltage protection - vari | Yes, 4 | |
| Output overvoltage protection - plug in modular surge arrester (-SX version) |
4, Type 2 | |
| Operating performance | ||
| Maximum efficiency (ηmax) | 0.98 | 0.99 |
| Weighted efficiency (EURO) | 98.0% / - | 98.0% / - |
| Communication | ||
| Remote monitoring | VSN300 Wifi Logger Card (opt.), VSN700 Data Logger (opt.) | |
| Wireless local monitoring | VSN300 Wifi Logger Card (opt.) | |
| User interface | LEDs, Display (option) | |
| Communication interface | 2 (RS485) | |
| Environmental | ||
| Ambient temperature range | -25...+60°C/ -13...14°F with derating above 50°C /140°F |
-25...+60°C/-13...140°F with derating above 45°C/113°F |
| Relative humidity | 4%...100% condensing | |
| Sound pressure level, typical | 75 dB(A) @1 m | |
| Maximum operating altitude without derating | 2000 m / 6560 ft | |
| Physical | ||
| Environmental protection rating | IP65 (IP54 for cooling section) | |
| Cooling | Forced air | |
| Dimension (H x W x D) | 725 mm x 1491 mm x 315 mm / 28.5” x 58.7” x 12.4” | |
| Weight | 95 kg / 209 lbs overall, 66 kg / 145 lbs electronic compartment, 15 kg / 33 lbs AC wiring box (full optional), 14kg / 31 lbs DC wiring box (full optional |
|
| Mounting system | Wall bracket, horizontal support | |
| Safety | ||
| Isolation level | Transformerless | |
| Marking | CE | |
| Safetyand EMC standar | IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12 |
|
| Grid standard (check your sales channel for availability) | CEI 0-21 4), CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105 4), G59/3, EN 50438 (not for all national appendices) 4), RD 1699 4), RD 413 4), RD 661 4), P.O. 12.3 4), AS 4777 4), BDEW, NRS-097-2-1 4), MEA 4), PEA 4), IEC 61727, IEC 60068, IEC 61683, VFR-2014, IEC 62116 |
|
| Available products variants | ||
| Inverter power module | TRIO-50.0-TL-OUTD-POWER MODULE | TRIO-60.0-TL-OUTD-POWER MODULE |
| DC wiring box options | ||
| Input connections with terminal blocks | DCWB-TRIO-50.0-TL-OUTD 5) | DCWB-TRIO-60.0-TL-OUTD |
| Input connections with terminal blocks + DC switch | DCWB-S-TRIO-50.0-TL-OUTD 5) | DCWB-S-TRIO-60.0-TL-OUTD |
| 12 quick input connections + fuses + DC switch + surge arresters Type 2 |
DCWB-SX-TRIO-50.0-TL-OUTD/12 INPUTS 5) | - |
| 16 quick input connections + fuses + DC switch + surge arresters Type 2 |
DCWB-SX-TRIO-50.0-TL-OUTD/16 INPUTS 5) | DCWB-SX-TRIO-60.0-TL-OUTD/16 INPUTS |
| 12 quick input connections + fuses + DC switch + surge arresters Type 1+2 |
DCWB-SY-TRIO-50.0-TL-OUTD 5) | - |
| AC wiring box options | ||
| AC output connections with terminal blocks | ACWB-TRIO-50.0-TL-OUTD | ACWB-TRIO-60.0-TL-OUTD |
| AC output connections with terminal blocks + AC switch | ACWB-S-TRIO-50.0-TL-OUTD | ACWB-S-TRIO-60.0-TL-OUTD |
| AC output connections with terminal blocks + AC switch + surge arrester Type 2 |
ACWB-SX-TRIO-50.0-TL-OUTD | ACWB-SX-TRIO-60.0-TL-OUTD |
ABB TRIO-50.0-TL-OUTD/TRIO-60.0-TL-OUTD-480 String Inverter Block Diagram
Efficiency Curves Of TRIO-50.0-TL-OUTD
Efficiency Curves Of TRIO-60.0-TL-OUTD
The PVS-50/60-TL is ABB’s cloud connected three-phase string solution enabling cost efficient large decentralized photovoltaic systems for both commercial and utility applications.
This new addition to the PVS string inverter family, with 3 independent MPPT and power ratings of up to 60 kW, has been designed with the objective to maximize the ROI in large systems with all the advantages of a decentralized configuration for both rooftop and ground-mounted installations.
Compact design Thanks to technological choices aimed at optimizing installation times and costs, the product design features the power module and wiring box enclosed in a single compact chassis thus saving installation resources and costs. The inverter comes in multiple versions also allowing the possibility to connect to third-party DC string combiners.
Ease of installation The horizontal and vertical mounting possibility creates flexibility for both rooftop and ground mounted installations. Moreover the cover is equipped with hinges and locks that are fast to open and reduce the risk of damaging the chassis and interior components when commissioning and performing maintenance actions.
Advanced cloud connected features Standard wireless access from any mobile device makes the configuration of inverter and plant easier and faster. Improved user experience thanks to a built-in User Interface (UI) enables access to advanced inverter configuration settings. The Installer for Solar Inverters mobile app and configuration wizard enable a quick multi-inverter installation, saving up to 70% commissioning time.
Fast system integrationIndustry standard Modbus (RTU/TCP)/SUNSPEC protocol enables fast system integration. Two ethernet ports enable fast and future-proof communication for PV plants. ABB plant portfolio integration Monitoring your assets is made easy, as every inverter is capable to connect to ABB cloud platform to secure your assets and profitability in long term.
Highlights
Technical Details
| Type code | PVS-50-TL | PVS-60-TL |
|---|---|---|
| Input side | ||
| Absolute maximum DC input voltage (Vmax,abs) | 1000 V | |
| Start-up DC input voltage (Vstart) | 420…700 V (Default 420 V) | 420…700 V (Default 500 V) |
| Operating DC input voltage range (Vdcmin...Vdcmax) | 0,7xVstart ...950 V (min 300 V) | 0,7xVstart ...950 V (min 360 V) |
| Rated DC input voltage (Vdcr) | 610 Vdc | 720 Vdc |
| Rated DC input power (Pdcr) | 52000 W | 61800 W |
| Number of independent MPPT | 3 (version SX and SX2) / 1 (versione standard e S) | |
| Maximum DC input power for each MPPT (PMPPT, max) | 19300W@30°C / 17500W@45°C | 23100W@30°C / 21000W@45°C |
| MPPT input DC voltage range ( VMPPTmin ... VMPPTmax) at Pacr | 480-800 Vdc | 570-800 Vdc |
| Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) | 36 A | |
| Maximum input short circuit current for each MPPT | 55 A (165 A in case of parallel MPPT) | |
| Number of DC input pairs for each MPPT | 5 | |
| DC connection type | Screw terminal block (Standard and -S version) or PV quick fit connector 1) (-SX and SX2 version) |
|
| Input protection | ||
| Reverse polarity protection | Yes, from limited current source | |
| Input over voltage protection for each MPPT | Type 2 / Type 1 + 2 (option) | |
| Photovoltaic array isolation control | According to local standard | |
| DC switch rating for each MPPT (version with DC switch) | 75 A / 1000 V for each MPPT | |
| Fuse rating (version with fuses) | 15 A / 1000 V | |
| Output side | ||
| AC grid connection type | Three-phase (3W+PE or 4W+PE), grounded WYE system only | |
| Rated AC power (Pacr @cosφ=1 ) | 50000 W | 60000 W |
| Maximum AC output power (Pacmax @cosö=1) | 55000 W up to 30°C | 66000 W up to 30°C |
| Maximum apparent power (Smax) | 55000 VA up to 30°C | 66000 VA up to 30°C |
| Rated AC grid voltage (Vac,r) | 400 V480 V | |
| AC voltage range | 320...480 V 2)384...571 V 2) | |
| Maximum AC output current (Iac,max) | 80 A | |
| Contributory fault current | 92 A | |
| Rated output frequency (fr) 3) | 50 Hz / 60 Hz | |
| Output frequency range (fmin...fmax) 3) | 47...53 Hz / 57…63 Hz 3) | |
| Nominal power factor and adjustable range | > 0.995; 0...1 inductive/capacitive with maximum Sn | |
| Total current harmonic distortion | <3% | |
| Maximum AC cable | 95mm2 copper/alluminum | |
| AC connection type | Screw terminal block, cable gland | |
| Output protection | ||
| Anti-islanding protection | According to local standard | |
| Maximum external AC overcurrent protection | 100 A | |
| Output overvoltage protection - varistor | Type 2 | |
| Operating performance | ||
| Maximum efficiency (hmax) | 0.98 | 0.99 |
| CN efficiency | 0.98 | 0.98 |
| Euro efficiency | 0.98 | 0.98 |
| Communication | ||
| Embedded communication interfaces | 3x RS485, 2X Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2,4 GHz) | |
| Communication protocol | Modbus RTU / TCP (Sunspec compliant); Aurora Protocol | |
| Remote monitoring services | Standard level access to Aurora Vision monitoring portal | |
| Advanced features | Integrated Web User Interface; Display (option);E mbedded logging and direct transferring of data to Cloud | |
| Environmental | ||
| Ambient temperature range | -25...+60°C (-13...140 °F) with derating above 45 °C (113 °F) with derating above 45 °C (113 °F) | |
| Relative humidity | 4%... 100% condensing | |
| Sound pressure level, typical | 75 dB(A) @1 m | |
| Maximum operating altitude | 4000 m (13123 ft) with derating above 2000 m / 6561 ft | |
ABB PVS-50/60-TL String Inverter Block Diagram
Click For More Details
Designed for commercial usage, the PVI-10/12.5, three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions.
The high speed and precise Maximum Power Point Tracking (MPPT) algorithm provides real-time power tracking and improved energy harvesting.
Two independent MPPTs and efficiency ratings up to 97.8%
Highlights
Technical Data And Types
| Type code | PVI-10.0-TL-OUTD | PVI-12.5-TL-OUTD |
|---|---|---|
| Input side | ||
| Absolute maximum DC input voltage (Vmax,abs) | 900 V | |
| Start-up DC input voltage (Vstart) | 360 V (adj. 250...500 V) | |
| Operating DC input voltage range (Vdcmin...Vdcmax) | 0.7 x Vstart…850 V (min 200 V) | |
| Rated DC input voltage (Vdcr) | 580 V | |
| Rated DC input power (Pdcr) | 10300 W | 12800 W |
| Number of independent MPPT | 2 | |
| Maximum DC input power for each MPPT (PMPPT, max) | 6500 W | 360...750 V |
| DC input voltage range with parallel configuration of MPPT at Pacr | 300...750 V | 360...750 V |
| DC power limitation with parallel configuration of MPPT | Linear derating from max to null [750 V≤VMPPT≤850 V] | |
| DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example | 6500 W [380 V≤VMPPT≤750 V] the other channel: Pdcr-6500 W [225 V≤VMPPT≤750 V] |
8000 W [445 V≤VMPPT≤750 V] |
| Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) | 34.0 A / 17.0 A | the other channel: Pdcr-8000 W |
| Maximum input short circuit current for each MPPT | 22.0 A | |
| Number of DC input pairs for each MPPT | 2 | |
| DC connection type | PV quick fit connector 3) | |
| Input protection | ||
| Reverse polarity protection | Inverter protection only, from limited current source | |
| Input over voltage protection for each MPPT | Yes | |
| Photovoltaic array isolation control | According to local standard | |
| DC switch rating for each MPPT (version with DC switch) | 25 A / 1000 V | |
| Fuse rating (version with fuses) | 15 A / 1000 V | |
| Output side | ||
| AC grid connection type | Three-phase 3W+PE or 4W+PE | |
| Rated AC power (Pacr @cosφ=1 ) | 10000 W | 12500 W |
| Maximum AC output power (Pacmax @cosö=1) | 11000 W 4) | 13800 W 5) |
| Maximum apparent power (Smax) | 11500 VA | 13800 VA |
| Rated AC grid voltage (Vac,r) | 400 V | |
| AC voltage range | 320...480 V 1) | |
| Maximum AC output current (Iac,max) | 16.6 A | 20.0 A |
| Contributory fault current | 19.0 A | 22.0 A |
| Rated output frequency (fr) 3) | 50 Hz / 60 Hz | |
| Output frequency range (fmin...fmax) 3) | 47...53 Hz / 57…63 Hz 3) | |
| Nominal power factor and adjustable range | > 0.995, adj. ± 0.9 with Pacr =10.0 kW, ± 0.8 with max 11.5 kVA |
> 0.995, adj. ± 0.9 with Pacr =12.5 kW, ± 0.8 with max 13.8 kVA |
| Total current harmonic distortion | < 2% | |
| AC connection type | Screw terminal block, cable gland M40 | |
| Output protection | ||
| Anti-islanding protection | According to local standard | |
| Maximum external AC overcurrent protection | 25.0 A | |
| Output overvoltage protection - varistor | 3 plus gas arrester | |
| Operating performance | ||
| Maximum efficiency (hmax) | 0.98 | |
| Weighted efficiency (EURO/CEC) | 97.1% / - | 97.2% / - |
| Feed in power threshold | 30.0 W | |
| Night consumption | < 1.0 W | |
| Communication | ||
| Wired local monitoring | PVI-USB-RS232_485 (opt.) | |
| Remote monitoring | VSN300 Wifi Logger Card (opt.), VSN700 Data Logger (opt.) | |
| Wireless local monitoring | VSN300 Wifi Logger Card (opt.) | |
| User interface | 16 characters x 2 lines LCD display | |
| Environmental | ||
| Ambient temperature range | -25...+60°C (-13...+140°F) | -25...+60°C (-13...140°F) |
| Relative humidity | with derating above 55°C (131°F) | with derating above 50°C (122°F) |
| Sound pressure level, typical | 50 dBA @ 1 m | |
| Maximum operating altitude | 2000 m / 6560 ft | |
| Physical | ||
| Environmental protection rating | IP65 | |
| Cooling | Natural | |
| Dimension (H x W x D) | 716 mm x 645 mm x 224 mm / 28.2” x 25.4” x 8.8” | |
| Weight | < 41.0 kg / 90.4 lbs | |
| Mounting system | Wall bracket | |
| Safety | ||
| Isolation level | Transformerless | |
| Marking | CE (50 Hz only), RCM | |
| Safety and EMC standard | EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, AS/NZS 60950.1, EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12 |
|
| Grid standard (check your sales channel for availability) | CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, C10/11, EN 50438 (not for all national appendices), RD 1699, RD 413, RD 661, P.O. 12.3, AS/NZS 4777, IEC 61727, IEC 62116, BDEW, MEA, NRS 097-2-1, VFR 2014 |
|
| Available products variants | ||
| Standard | PVI-10.0-TL-OUTD | PVI-12.5-TL-OUTD |
| With DC switch | PVI-10.0-TL-OUTD-S | PVI-12.5-TL-OUTD-S |
| With DC switch and fuse | PVI-10.0-TL-OUTD-FS | PVI-12.5-TL-OUTD-FS |
Graph
Efficiency Curves Of PVI-10.0-TL-OUTD
Efficiency Curves Of PVI-12.5-TL-OUTD
Features
Solar Hybrid UPS with inbuilt charge controllers are perfect choice for harnessing solar powers from panels to drive your household electrical loads.
Solar Hybrid UPS with inbuilt charge controllers are perfect choice for harnessing solar powers from panels to drive your household electrical loads.
The PVS-100/120-TL is ABB’s cloud connected three-phase string solution for cost efficient decentralized photovoltaic systems for both ground mounted and large commercial applications.
This platform, for extreme high power string inverters with power ratings up to 120 kW, maximizes the ROI for decentralized ground mounted and large rooftop applications. With six MPPT energy harvesting is optimized even in shading situations.
Extreme power with high integration levelThe extreme high power module up to 120 kW saves installation resources as less units are required. Due to its compact size further savings are generated in logistics and in maintenance. Thanks to the integrated DC/AC disconnection, 24 string connections, fuses and surge protection no additional boxes are required.
Ease of installationThe horizontal and vertical mounting possibility creates flexibility for both ground mounted and rooftop installations. Covers are equipped with hinges and locks that are fast to open and reducethe risk of damaging the chassis and interior components when commissioning and performing maintenance actions.
Standard wireless access from any mobile device makes the configuration of inverter and plant easier and faster. Improved user experience thanks to a build in User Interface (UI) enables access to advanced inverter configuration settings.
The installer mobile APP, available for Android/iOS devices, further simplifies multi-inverter installations.
The design supports both copper and aluminum cabling even up to 185 mm2 cross section to minimize the energy losses.
Fast system integrationIndustry standard Modbus/SUNSPEC protocol enables fast system integration. Two ethernet ports enable fast and future proof communication for PV plants.ABB plant portfolio integration Monitoring your assets is made easy as every inverter is capable to connect to ABB plant portfolio manager to secure your assets and profitability inlong term. Design flexibility and shade toleranceThe double stage conversion topology and six MPPT guarantee maximum flexibility for the system design on rooftops or hilly ground. With this technological choice energy harvesting isoptimized even in shading situations.
Highlights
Notes :
Technical Data And Types
| Type code | PVS-100-TL | PVS-120-TL |
|---|---|---|
| Input side | ||
| Absolute maximum DC input voltage (Vmax,abs) | 1000V | |
| Start-up DC input voltage (Vstart) | 420V (400…500 V) | |
| Operating DC input voltage range (Vdcmin...Vdcmax) | 360…1000 V | |
| Rated DC input voltage (Vdcr) | 620V | 720V |
| Rated DC input power (Pdcr) | 102 000W | 123 000W |
| Number of independent MPPT | 6 | |
| MPPT input DC voltage range at (VMPPTmin...VMPPTmax) at Pacr | 480…850V | 570…850V |
| Maximum DC input power for each MPPT (PMPPT,max) | 17500 W [480V≤VMPPT≤850V | 20500 W [570V≤VMPPT≤850V |
| Maximum DC input current for each MPPT (Idcmax) | 36 A | |
| Maximum input short circuit current (Iscmax) for each MPPT | 50 A 1) | |
| Number of DC input pairs for each MPPT | 4 | |
| DC connection type | PV quick fit connector 2) | |
| Input protection | ||
| Reverse polarity protection | Yes, from limited current source | |
| Input over voltage protection for each MPPT replaceable surge arrester | Type II with monitoring only for SX and SX2 versions; Type I+II with monitoring only for SY and SY2 versions |
|
| Photovoltaic array isolation control | as per IEC62109 | |
| DC switch rating for each MPPT (version with DC switch) | 50 A / 1000 V | |
| Fuse rating (version with fuses) | 15 A / 1000 V 3) | |
| String current monitoring | SX2, SY2: (24ch) Individual string current monitoring; SX, SY: (6ch) Input current monitoring per MPPT |
|
| Output side | ||
| AC grid connection type | Three-phase 3W+PE or 4W+PE | |
| Rated AC power (Pacr @cosφ=1 ) | 100 000 W | 120 000 W |
| Maximum AC output power (Pacmax @cosö=1) | 100 000 W | 120 000 W |
| Maximum apparent power (Smax) | 100 000 VA | 120 000 VA |
| Rated AC grid voltage (Vac,r) | 400 V | 480 V |
| AC voltage range | 320...480 V 1) | 384...576 3) |
| Maximum AC output current (Iac,max) | 145 A | |
| Rated output frequency (fr) 3) | 50 Hz / 60 Hz | |
| Output frequency range (fmin...fmax) 3) | 45...55 Hz / 55…65 Hz 5) | |
| Nominal power factor and adjustable range | > 0.995, 0…1 inductive/capacitive with maximum Smax | |
| Total current harmonic distortion | < 3% | |
| Maximum AC cable | 185mm2 Aluminum and copper | |
| AC connection type | Provided bar for lug connections M10, single core cable glands 4xM40 and M25, multi core cable gland M63 as option |
|
| Output protection | ||
| Anti-islanding protection | According to local standard | |
| Maximum external AC overcurrent protection | 225 A | |
| Output overvoltage protection - replaceable surge protection device |
Type 2 with monitoring | |
| Operating performance | ||
| Maximum efficiency (ηmax) | 0.98 | 0.99 |
| Weighted efficiency (EURO) | 0.98 | 0.99 |
| Communication | ||
| Embedded communication interfaces | 1x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2,4 GHz) | |
| User interface | 4 LEDs, Web User Interface | |
| Communication protocol | Modbus RTU/TCP (Sunspec compliant) | |
| Commissioning tool | Web User Interface, Mobile APP/APP for plant level | |
| Remote monitoring services | Aurora Vision® monitoring portal | |
| Advanced features | Embedded logging, direct telemetry data transferring to ABB cloud | |
| Environmental | ||
| Ambient temperature range | -25...+60°C /-13...140°F with derating above 40°C / 104 °F | |
| Relative humidity | 4%...100% condensing | |
| Sound pressure level, typical | 68dB(A) @ 1m | |
| Maximum operating altitude | 2000 m / 6560 ft | |
| Physical | ||
| Environmental protection rating | IP 66 (IP54 for cooling section | |
| Cooling | Forced air | |
| Dimension (H x W x D) | 869x1086x419 mm / 34.2” x 42.8” x 16.5” | |
| Weight | 70kg / 154 lbs for power module ; ~55kg / 121 lbs for wiring box Overall max 125 kg / 276 lbs |
|
| Mounting system | Mounting bracket vertical & horizontal support | |
| Safety | ||
| Isolation level | Transformerless | |
| Marking | CE conformity according to LV and EMC directives | |
| Safetyand EMC standar | IEC/EN 62109-1, IEC/EN 62109-2 | |
| Grid standard (check your sales channel for availability) | CEI 0-16, CEI 0-21, IEC 61727, IEC 62116, IEC 60068, IEC 61683, JORDAN IRR-DCC-MV, AS/ NZS4777.2, VDE-AR-N 4105, VDE V 0-126-1-1, VFR 2014, Belg C10-C11, UK59/3, P.O. 12.3, ITC-BT-40, EN50438 Generic +Ireland, CLC-TS 50549-1/2 |
|
| Available products variants | ||
| Inverter power module | PVS-100-TL-POWERMODULE-400 | PVS-120-TL-POWERMODULE-480 |
| Input with 24 quick fit connectors pairs + String fuses (both positive and negative pole) + DC disconnect switches + AC disconnect switch + AC and DC overvoltage surge arresters (Type II) + individual string monitoring (24 ch.) |
WB-SX2-PVS-100-TL | WB-SX2-PVS-120-TL |
| Input with 24 quick fit connectors pairs + String fuses (positive pole) + DC disconnect switches + AC and DC overvoltage surge arresters (Type II) + MPPT level input current monitoring (6 ch.) |
WB-SX-PVS-100-TL | WB-SX-PVS-120-TL |
| Input with 24 quick fit connectors pairs + String fuses (positive pole) + DC disconnect switches + AC and DC overvoltage surge arresters (Type II for AC and Type I+II for DC) + MPPT level input current monitoring (6 ch.) |
WB-SY-PVS-100-TL | WB-SY-PVS-120-TL |
| Input with 24 quick fit connectors pairs + String fuses (both positive and negative pole) + DC disconnect switches + AC disconnect switch + AC and DC overvoltage surge arresters (Type II for AC and Type I+II for DC) + individual string monitoring (24 ch.) |
WB-SY2-PVS-100-TL | WB-SY2-PVS-120-TL |
| Optional available | ||
| Support for multi core AC cable M63 + M25 (PE) | AC output panel M63 for wiring box | |
| AC multicore cable gland plate | Supports M63 Ø 37…53mm + M25 Ø 10...17mm | |
Graph
ABB string inverters cost-efficiently convert the direct current (DC) generated by solar modules into high quality three-phase alternating current (AC) that can be fed into the power distribution network (i.e. grid). Designed to meet the needs of the entire supply chain – from system integrators and installers to end users – these transformerless, three-phase inverters are designed for decentralized photovoltaic (PV) systems installed in commercial and industrial systems up to megawatt (MW) sizes.
A three-phase inverter from the world’s leading power technology company
ABB, a global leader in power and automation technologies, brings decades of experience, technology leadership and application know-how from renewable energies to this new string inverter. Such experience and technology ensures high quality, safe and reliable solar inverters are delivered every time.
High power package for decentralized PV systems
ABB’s three-phase PRO-33 string inverter is designed for medium and large decentralized PV systems either on large-scale commercial and industrial rooftops or ground-mounted PV plants. The inverter offers cost-efficiency in a high power, wall-mountable package with very high conversion efficiency. The all-in-one design with built-in and monitored PV plant protection devices reduces the need of costly external devices.
The single maximum power point tracker (MPPT) and optimized MPPT window are suitable for uniformshaped PV plants with long strings connected to the inverter. The high maximum DC input voltage of up to 1100 V gives PV plant designers extra flexibility and allows more PV modules to be connected in series to reduce cabling costs.
Highlights
Configurable all-in-one design
The ABB PRO-33.0 string inverter comes in three product variants. The standard model with or without DC switch is designed for use with an external string combiner box. The all-in-one model with built-in string combiner box includes a DC switch, string current monitoring with alarm, PV fuses, monitored surge protection devices and tool-less solar quick connectors. The inverter’s all-in-one design, with built-in and monitored PV plant protection devices, reduces the need of costly external devices.
High total efficiency maximizes return on investment
The PRO-33.0 inverter offers a high conversion and MPP tracking efficiency in all conditions. A flat efficiency curve provides high revenues in low and high radiation conditions.
Fast and easy commissioning
Fast PV plant commissioning is enabled via preprogrammed country grid code settings that are easily selectable. Extensive certification ensures wide grid code compatibility. Plug and Play DC and AC connectors enable fast and safe cabling. A touch protected installation area provides additional safety and comfort for inverter installation and maintenance.
Technical Data And Types
| Type designation | 33 kW |
|---|---|
| PRO-33.0-TL-OUTD | |
| Input side | |
| Absolute maximum DC input voltage (Vmax,abs) | 1100 V 4) |
| Startup DC input voltage (Vstart) | 610 V |
| Operating DC input voltage range (Vdcmin...Vdcmax) | 580 to 950 V |
| Rated DC input voltage (Vdcr) | 580 V |
| Rated DC input power (Pdcr) | 33 700 W |
| Number of independent MPPT | 1 |
| MPPT input DC voltage range (VMPPTmin...VMPPTmax) at Pacr | 580 to 850 V |
| Maximum DC input current (Idcmax)/for each MPPT (IMPPTmax) | 58 A |
| Maximum input short circuit current for each MPPT | 80 A |
| Number of DC input pairs for each MPPT | 1 in Standard and -S version/8 in -SX version |
| DC connection type | PV quick fit connector 3) on -SX version / Screw terminal block on Standard and -S version |
| Input protection | |
| Reverse polarity protection | Yes, from limited current source |
| Input over voltage protection for each MPPT - varistor (-/S) version | Yes |
| Input over voltage protection - plug in modular surge arrester (-SX version) | Type 2 |
| Photovoltaic array isolation control | According to local standard |
| DC switch rating for each MPPT (version with DC switch) | 58 A / 1000 V, 50 A / 1200 V |
| Fuse rating (versions with fuses ) | 15 A / 1100 V |
| Output side | |
| AC grid connection type | Three-phase 3W+PE or 4W+PE |
| Rated AC power (Pacr @cosφ>0.99 ) | 33 000 W |
| Maximum apparent power (Smax) | 33 000 VA |
| Rated AC grid voltage (Vac,r) | 400 V |
| AC voltage range | 320 to 480 V 1) |
| Maximum AC output current (Iac,max) | 50.3 A |
| Contributory fault current | 50.3 A |
| Rated output frequency (fr) | 50 Hz/60 Hz |
| Output frequency range (fmin...fmax) | 47 to 53 Hz/57 to 63 Hz 2) |
| Nominal power factor and adjustable range | > 0.995, with Pacr = 33.0 kW, adj. ± 0.9 with Pacr =29.7 kW, adj. ± 0 to 1 with S = 33.0 kVA |
| Total current harmonic distortion | < 3% |
| AC connection type | Fixed plug type connector |
| Output protection | |
| Anti-islanding protection | According to local standard |
| Maximum external AC overcurrent protection | 80 A |
| Output overvoltage protection - varistor | 5 |
| Operating performance | |
| Maximum efficiency (ηmax) | 0.98 |
| Weighted efficiency (EURO/CEC) | 98.0% / 98.1% |
| Feed in power threshold | 20 W |
| Night consumption | < 1 W |
| Communication | |
| Remote monitoring | VSN700 Data Logger (opt.) |
| User interface | Detachable graphical display |
| Environmental | |
| Ambient temperature range | -25 to +60°C /-13 to 140°F wi th derating above 45°C/113°F |
| Relative humidity | 0 to 100% condensing |
| Sound pressure level, typical | 67 dBA @ 1 m |
| Maximum operating altitude without derating | 3000 m / 9840 ft |
| Physical | |
| Environmental protection rating | IP65 (IP54 fans) |
| Cooling | Forced |
| Dimension (H x W x D) mm/inch | 740 x 520 x 300 mm / 29.1" x 20.5" x 11.8" |
| Weight kg / lb | < 66.0 kg / 146 lbs (standard version) |
| Mounting system | Wall bracket |
| Safety | |
| Isolation level | Transformerless |
| Marking | CE, RCM |
| Safety and EMC standard | IEC/EN 62109-1, IEC/EN 62109-2, EN61000-6-2, AS/NZS 3200, EN61000-6-3, EN61000-3-11, EN61000-3-12 |
| Grid standard (check availability) | CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, C10/11, EN 50438 (not for all national appendices), PPC Greece, RD 1699, RD 413, RD 661, P.O. 12.3, UNE206007-1, AS 4777, BDEW, NRS-097-2-1, SAGC, MEA, PEA, IEC 61727, IEC 62116, ABNT NBR16149/16150, VFR-2014 |
| Available product variants | |
| Standard | PRO-33.0-TL-OUTD-400 |
| With DC switch | PRO-33.0-TL-OUTD-S-400 |
| With DC switch, fuses and DC surge arresters | PRO-33.0-TL-OUTD-SX-400 |
ABB PRO-33.0-TL-OUTD String Inverter Block Diagram
Efficiency Curves Of PRO-33.0-TL-OUTD
The PVS-175-TL is ABB’s innovative three-phase string inverter, delivering a six-in-one solution to enhance and optimize solar power generation for ground mountedutility scale applications.
High power densityThis new high-power string inverter, with the largest high power density within the 1500 Vdc segment, delivers up to 185 kVA at 800 Vac and can achieve an ultra-high-power density of 1.3 kW/kg. This not only maximizes the ROI for ground-mounted utility-scale applications but also reduces Balance of System costs (i.e. AC side cabling) for small to large scale, free field ground mounted PV installations.
Design flexibilityThe inverter comes equipped with 12 MPPT, the highest available in the market, assuring maximum PV plant design flexibility and increasing yields also in case of complex installations.
Installer friendly design Quick and easy installation, thanks to plug and play connectors, as the existing PV module’s mounting systems can be used to install the inverters, thus saving time and cost on site preparation and hire of plant.
The fuse and combiner free design eliminates the need for external components, such as separate DC combiner boxes and AC first level combiners, thanks to the integrated DC disconnect and AC wiring compartment with optional AC disconnect.
The Advanced Cooling Concept preserves the lifetime of the system and minimizes O&M costs thanks to internal heavy-duty inverter cooling fans. These can be easily removed during scheduled maintenance cycles whilst the power module can be easily replaced without removing the wiring box.
Advanced communication for O&MStandard wireless access from any mobile device makes the configuration of inverter and plant easier and faster. Improved user experience thanks to a built-in User Interface (UI) enables access to advanced inverter configuration settings. The Installer for Solar Inverters mobile APP and configuration wizard enable a quick multi-inverter installation and commissioning thus reducing the time spent on site.
Fast system integrationIndustry standard Modbus (RTU/TCP)/SUNSPEC protocol enables fast system integration. Two Ethernet ports enable fast and future-proof communication for PV plants.
Protect your assetsMonitoring your assets is made easy, as every inverter is capable to connect to ABB cloud platform and thanks to the state-of-the-art cybersecurity and Arc Fault Detection option, your assets and profitability are secure in the long term.
Highlights
Note
Technical Data And Types
| Type code | PVS-175-TL | |
|---|---|---|
| Input side | ||
| Absolute maximum DC input voltage (Vmax,abs) | 1500 V | |
| Start-up DC input voltage (Vstart) | 650 V (650…1000 V) | |
| Operating DC input voltage range (Vdcmin...Vdcmax) | 0.7 x Vstart…1500 V (min 600 V) | |
| Rated DC input voltage (Vdcr) | 1250 V | |
| Rated DC input power (Pdcr) | 188 000 W @ 30°C (177 kW @ 40°C) | |
| Number of independent MPPT | 12 | |
| MPPT input DC voltage range at (VMPPTmin...VMPPTmax) at Pacr | 850..1350 V | |
| Maximum DC input power for each MPPT (PMPPT,max) | 22 A | |
| Maximum input short circuit current (Iscmax) for each MPPT | 30 A | |
| Number of DC input pairs for each MPPT | 2 DC inputs per MPPT | |
| DC connection type | PV quick fit connector 2) | |
| Input protection | ||
| DC Series Arc Fault Circuit Interrupter | Type I acc. to UL 1699B 2) with single-MPPT sensing capability | |
| Reverse polarity protection | Yes, from limited current source | |
| Input over voltage protection for each MPPT - varistor | Yes, 2 (S/S2 version only) | |
| Input over voltage protection for each MPPT replaceable surge arrester | Type 2 with monitoring (SX/SX2 version only) | |
| Photovoltaic array isolation control (insulation resistance) | Yes, acc. to IEC 62109-2 | |
| Residual Current Monitoring Unit (leakage current protection) | Yes, acc. to IEC 62109-2 | |
| DC Load Breaking Disconnect Switch (rating for each MPPT) | 32A/1500 V | |
| Fuse rating | N/A, No fuses | |
| String current monitoring | MPPT-level current sense | |
| Output side | ||
| AC grid connection type | Three phase 3W+PE | |
| Rated AC power (Pacr @cosφ=1 ) | 175 000 W @ 40°C | |
| Maximum AC output power (Pacmax @cosö=1) | 185 000 W @≤ 30°C | |
| Maximum apparent power (Smax) | 185 000 VA | |
| Rated AC grid voltage (Vac,r) | 800 V | |
| AC voltage range | (552...960) 3) | |
| Maximum AC output current (Iac,max) | 134 A | |
| Rated output frequency (fr) 3) | 50 Hz/60 Hz | |
| Output frequency range (fmin...fmax) 3) | 45...55 Hz/55…65 Hz 3) | |
| Nominal power factor and adjustable range | > 0.995, 0…1 inductive/capacitive with maximum Smax | |
| Total current harmonic distortion | < 3% | |
| Max DC current injection (% of In) | < 0.5%*In | |
| Maximum AC Cable / multi core | 3x185mm2 copper/aluminum (cable gland M63, max cable dia. 53mm) | |
| Maximum AC Cable / single core | 4x1x185mm2 copper/aluminum (cable gland M40, max cable dia. 28mm) | |
| AC connection type | Copper Busbar for lug connections with M10 bolts (included) | |
| Output protection | ||
| Anti-islanding protection | According to local standard | |
| Maximum external AC overcurrent protection | 200 A | |
| Output overvoltage protection - replaceable surge protection device |
Type 2 with monitoring | |
| Operating performance | ||
| Maximum efficiency (ηmax) | 0.99 | |
| Weighted efficiency (EURO) | 0.99 | |
| Communication | ||
| Embedded communication interfaces | Dual port Ethernet, Wi-Fi 4), RS-485 | |
| User interface | 4 LEDs, Web User Interface, Mobile APP | |
| Communication protocol | Modbus RTU/TCP (Sunspec) | |
| Commissioning tool | Web User Interface, Mobile APP/APP for plant level | |
| Monitoring | Plant Portfolio Manager, Plant Viewer | |
| FW update | Remote inverter FW (all components) upgrade via Ethernet/Wi-Fi interface locally/remotely |
|
| Parameter upgrade | Remote inverter parameter (all components) upgrade via Ethernet/Wi-Fi interface locally/remotely |
|
| Environmental | ||
| Operating ambient temperature range | -25...+60°C/-13...140°F with derating above 40°C/133 °F | |
| Relative humidity | 4%...100% condensing | |
| Sound pressure level, typical | 65dB(A) @ 1m | |
| Maximum operating altitude | 2000 m / 6560 ft | |
| Physical | ||
| Environmental protection rating | IP 65 (IP54 for cooling section) | |
| Cooling | Forced air | |
| Dimension (H x W x D) | 869x1086x419 mm/34.2” x 42.8” x 16.5” | |
| Weight | ~70kg/154 lbs for power module ~75kg/165 lbs for wiring box Overall 145 kg/319 lbs |
|
| Mounting system | Mounting bracket (vertical support only) | |
| Safety | ||
| Isolation level | Transformerless | |
| Marking | CE | |
| Safetyand EMC standar | IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN55011:2017 |
|
| Grid standard (check your sales channel for availability) | TBD | |
| Available products variants | ||
| Inverter power module | PVS-175-TL-POWER MODULE | |
| 24 quick fit connector pairs (2 each mppt) + DC switches + DC side varistors | WB-S-PVS-175-TL | |
| 24 quick fit connector pairs (2 each mppt) + DC switches + DC side varistors + AC disconnection switch |
WB-S2-PVS--175-TL | |
| 24 quick fit connector pairs (2 each mppt) + DC switches + SPD Type 2 | WB-SX-PVS-175-TL | |
| 24 quick fit connector pairs (2 each mppt) + DC switches + AC disconnection switch + SPD Type 2 Pluggable Cartridges (DC & AC) |
WB-SX2-PVS--175-TL | |
| Optional available | ||
| DC Series Arc Fault Circuit Interrupter | Type I acc. to UL 1699B 2) with single-MPPT sensing capability | |
| AC Plate, Single Core Cables | Plate with 5 individual AC cable glands: 4 x M40: Ø 19...28mm, 1 x M25: Ø 10...17mm |
|
| AC Plate, Multi Core Cables | Plate with 2 individual AC cable glands: Opt.1: 1 x M63: Ø 34…45mm, 1 x M25: Ø 10...17mm Opt.2: 1 x M63: Ø 37…53mm, 1 x M25: Ø 10...17mm |
|
| DC link recharge circuit | Night time operation with restart capability | |
| Anti-PID 5) | Based on night time polarization of the array | |
ABB PVS-175-TL String Inverter Block Diagram
The all-in-one residential threephase TRIO-5.8, 7.5 and 8.5 kW inverters deliver performance, ease of use and installation, monitoring and control. With their 98% peak efficiency andwide input voltage range, the residential TRIO inverter means flexible installations and powerful output.
Commercial grade engineering at residential scale
The topology of the larger, commercial TRIO inverters has been redesigned to ensure that the TRIO- 5.8/7.5/8.5 models also enjoy high conversion efficiency across a wide range of input oltages. Optional integrated dataloggers and smart grid functionality, remote firmware updating and elegantly simple sliding front covers make these all-in-one devices easy to install and maintain. In short, they are commercial grade engineering at residential scale.
Inverters packed with powerful featuresThe double maximum power point tracker (MPPT) gives maximum installation flexibility for an optimal energy production (TRIO-7.5/8.5 models). This line of inverters can integrate power control, monitoring functionalities and environmental sensor inputs, without requiring external components.
A compact Ethernet expansion card provides data logging functionality for monitoring the main parameters of the plant as well as advanced O&M operations both locally (with the integrated webserver) and remotely (with the AV Plant Portfolio Manager portal), via a LAN connection.
The outer cover with its natural cooling mechanism qualifies at IP65 environmental protection level for external use. It provides maximum reliability and ease of installation, with a sliding front panel giving access to the connection and configuration area without requiring the complete removal of the cover.
Highlights
Technical Data And Types
| Type code | TRIO-5.8-TL-OUTD | TRIO-7.5-TL-OUTD | TRIO-8.5-TL-OUTD |
|---|---|---|---|
| Input side | |||
| Absolute maximum DC input voltage (Vmax,abs) | 1000 V | ||
| Start-up DC input voltage (Vstart) | 350 V (adj. 200...500 V) | ||
| Operating DC input voltage range (Vdcmin...Vdcmax) | 0.7 x Vstart…950 V (min 200 V) | ||
| Rated DC input voltage (Vdcr) | 620 V | ||
| Rated DC input power (Pdcr) | 5950 W | 7650 W | 8700 W |
| Number of independent MPPT | 1 | 2 | 2 |
| Maximum DC input power for each MPPT (PMPPTmax) | 6050 W Linear derating from max to null [800 V≤VMPPT≤950 V] |
4800 W | 4800 W |
| MPPT input DC voltage range (VMPPTmin ... VMPPTmax) at Pacr | 320…800 V | - | - |
| DC input voltage range with parallel configuration of MPPT at Pacr |
- | 320…800 V | 320…800 V |
| DC power limitation with parallel configuration of MPPT | - | Linear derating from max to null [800 V≤VMPPT≤950 V] | |
| DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example |
- | 4800 W [320 V≤VMPPT≤800 V] the other channel: Pdcr-4800 W [215 V≤VMPPT≤800 V] |
4800 W [320 V≤VMPPT≤800 V] the other channel: Pdcr-4800 W [290 V≤VMPPT≤800 V] |
| Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) |
18.9 A | 30.0 A / 15.0 A | 30.0 A / 15.0 A |
| Maximum input short circuit current for each MPPT | 24.0 A | 20.0 A | 20.0 A |
| Number of DC input pairs for each MPPT | 2 (-S version) | ||
| DC connection type | PV quick fit connector 3) on -S version / Screw terminal block on standard version |
||
| Input protection | |||
| Reverse polarity protection | Yes, from limited current source | ||
| Input over voltage protection for each MPPT - varistor | Yes, 4 | ||
| Photovoltaic array isolation control | According to local standard | ||
| DC switch rating for each MPPT (version with DC switch) | 16 A /1000 V, 25 A / 800 V | ||
| Output side | |||
| AC grid connection type | Three-phase 3W+PE or 4W+PE | ||
| Rated AC power (Pacr @cosφ=1 ) | 5800 W | 7500 W | 8500 W |
| Maximum apparent power (Smax) | 5800 VA | 7500 VA | 8500 VA |
| Rated AC grid voltage (Vac,r) | 400 V | ||
| AC voltage range | 320...480 V 1) | ||
| Maximum AC output current (Iac,max) | 10.0 A | 12.5 A | 14.5 A |
| Contributory fault current | 12.0 A | 14.5 A | 16.5 A |
| Rated output frequency (fr) | 50 Hz / 60 Hz | ||
| Output frequency range (fmin...fmax) | 47...53 Hz / 57…63 Hz 2) | ||
| Nominal power factor and adjustable range | > 0.995, adj. ± 0.9 with Pacr =5.22 kW, ± 0.8 with max 5.8 kVA |
> 0.995, adj. ± 0.9 with Pacr =6.75 kW, ± 0.8 with max 7.5 kVA |
> 0.995, adj. ± 0.9 with Pacr =7.65 kW, ± 0.8 with max 8.5 kVA |
| Total current harmonic distortion | < 2% | ||
| AC connection type | Screw terminal block, cable gland M32 | ||
| Output protection | |||
| Anti-islanding protection | According to local standard | ||
| Maximum external AC overcurrent protection | 16.0 A | 16.0 A | 20.0 A |
| Output overvoltage protection - varistor | 4 plus gas arrester | ||
| Operating performance | |||
| Maximum efficiency (ηmax) | 0.98 | ||
| Weighted efficiency (EURO/CEC) | 97.4% / - | 97.5% / - | 97.5% / - |
| Feed in power threshold | 32 W | 36 W | 36 W |
| Night consumption | < 3 W | ||
| Communication | |||
| Wired local monitoring | Ethernet card with webserver (opt.), PVI-USB-RS232_485 (opt.) | ||
| Remote monitoring | Ethernet card (opt.), VSN300 Wifi Logger Card (opt.), VSN700 Data Logger (opt.) | ||
| Wireless local monitoring | VSN300 Wifi Logger Card (opt.) | ||
| User interface | Graphic display | ||
| Environmental | |||
| Ambient temperature range | -25...+60°C /-13...140°F with derating above 50°C/122°F | ||
| Relative humidity | 0...100% condensing | ||
| Sound pressure level, typical | 50 dBA @ 1 m | ||
| Maximum operating altitude without derating | 2000 m / 6560 ft | ||
| Physical | |||
| Environmental protection rating | IP65 | ||
| Cooling | Natural | ||
| Dimension (H x W x D) | 641mm x 429 mm x 220 mm/ 25.2” x 16.9” x 8.7” (855 mm x 429 mm x 237 mm/ 33.7” x 16.9” x 9.3” with open front cover) |
||
| Weight | 25.0 kg / 55.1 lbs | 28.0 kg / 61.7 lbs | 28.0 kg / 61.7 lbs |
| Mounting system | Wall bracket | ||
| Safety | |||
| Isolation level | Transformerless | ||
| Marking | CE (50 Hz only), RCM | ||
| Safety and EMC standard | EN 62109-1, EN 62109-2, AS/NZS3100, EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3 |
||
| Grid standard (check your sales channel for availability) | CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, RD 1699, RD 413, NRS-097-2-1, AS 4777, IEC 61727, IEC 62116, VFR 2014 |
||
| Available products variants | |||
| Standard | TRIO-5.8-TL-OUTD-400 | TRIO-7.5-TL-OUTD-400 | TRIO-8.5-TL-OUTD-400 |
| With DC switch | TRIO-5.8-TL-OUTD-S-400 | TRIO-7.5-TL-OUTD-S-400 | TRIO-8.5-TL-OUTD-S-400 |
Efficiency Curves Of TRIO-5.8-TL-OUTD
Efficiency Curves Of TRIO-8.5-TL-OUTD
ABB TRIO-5.8/7.5/8.5-TL-OUTD String Inverter Block Diagram
The new UNO-DM-PLUS singlephase inverter family, with power ratings from 1.2 to 3.0 kW, is the optimal solution for residential installations.
One size fits allThe new design wraps ABB’s quality and engineering into a lightweight and compact package thanks to technological choices optimized for installations with a uniform orientation. All power ratings share the same overall volume, allowing higher performance in a minimum space.
Easy to install, fast to commission
Smart capabilitiesThe embedded logging capabilities and direct transferring of the data to Internet (via Ethernet or WLAN) allow customers to enjoy the whole Aurora
Vision® remote monitoring experience.
Highlights
Technical Data And Types
| Type code | UNO-DM-1.2-TL-PLUS | UNO-DM-2.0-TL-PLUS | UNO-DM-3.0-TL-PLUS |
|---|---|---|---|
| Input side | |||
| Absolute maximum DC input voltage (Vmax,abs) | 600 V | ||
| Start-up DC input voltage (Vstart) | 120 V (adj. 100…150 V) | 150 V (adj. 100…250 V) | 150 V (adj. 100…250 V) |
| Operating DC input voltage range (Vdcmin...Vdcmax) | 0.7 x Vstart...580 V (min 90 V) | ||
| Rated DC input voltage (Vdcr) | 185 V | 10.0 A | 300 V |
| Rated DC input power (Pdcr) | 1500 W | 2500 W | 3300 W |
| Number of independent MPPT | 1 | 1 | 1 |
| Maximum DC input power for each MPPT (PMPPTmax) | 1500 W | 2500 W | 3300 W |
| DC input voltage range with parallel configuration of MPPT at Pacr | 100…530 V | 210...530 V | 320...530 V |
| DC power limitation with parallel configuration of MPPT | N/A | N/A | N/A |
| DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example | N/A | N/A | N/A |
| Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) | 10.0 A | 10.0 A | 10.0 A |
| Maximum input short circuit current for each MPPT | 12.5 A | 12.5 A | 12.5 A |
| Number of DC input pairs for each MPPT | 1 | ||
| DC connection type 1) | Quick Fit PV Connector | ||
| Input protection | |||
| Reverse polarity protection | Yes, from limited current source | ||
| Input over voltage protection for each MPPT-varistor | Yes | ||
| Photovoltaic array isolation control | According to local standard | ||
| DC switch rating for each MPPT (version with DC switch) | 25 A / 600 V | ||
| Output side | |||
| AC grid connection type | Single-phase | ||
| Rated AC power (Pacr @cosφ=1 ) | 1200 W | 2000 W | 3000 W |
| Maximum AC output power (Pacmax @cosö=1) | 1200 W | 2000 W | 3000 W |
| Maximum apparent power (Smax) | 1200 W | 2000 W | 3000 W |
| Rated AC grid voltage (Vac,r) | 230 V | ||
| AC voltage range 2) | 180...264 V | ||
| Maximum AC output current (Iac,max) | 5.5 A | 10.0 A | 14.5 A |
| Contributory fault current | 10.0 A | 12.0 A | 16.0 A |
| Rated output frequency (fr) 3) | 50/60 Hz | ||
| Output frequency range (fmin...fmax) 3) | 47...53/57...63 Hz | ||
| Nominal power factor and adjustable range | > 0.995, adj. ± 0.1 - 1 (over/under excited) | ||
| Total current harmonic distortion | < 3.5% | ||
| AC connection type | Female connector from panel | ||
| Output protection | |||
| Anti-islanding protection | According to local standard | ||
| Maximum external AC overcurrent protection | 10.0 A | 16.0 A | 16.0 A |
| Output overvoltage protection - varistor | 2 (L - N / L - PE) | ||
Graph
Click For More Details
Product Features
With Delta's cutting-edge technology, the commercial series Solar Inverters are with efficiencies as high as 98.3%. These inverters are compact in size with durable quality to ensure smooth PV system operation. IP65 enclosure provides higher level of protection and enhances its durability in a harsh outdoor environment.
Notes
Technical Data
| Input (DC) | RPI-M10A |
|---|---|
| Recommended Max. DC Power | 12.5 kWp |
| Max. Input Voltage | 1000 V |
| DC Voltage Range | 200 - 1000 V |
| Start-up Voltage | >250 V |
| Start-up Power | 40W |
| MPPT Voltage Range | 200 - 1000 V |
| MPP Voltage Range, Full Power | 415 - 800 V |
| Nominal DC Voltage | 600 V |
| Max. Input Current per MPPT | 15 A / 10 A |
| Total Input Current | 25 A |
| Maximum Short Circuit Current | 19.5A / 13A |
| No. of Independent MPP Trackers | 2 |
| Unbalanced Input (%) | 60 / 40 |
| Input Connection Type | 3 pair MC4 |
| DC Disconnection Switch | Yes (Inbuilt) |
| Output (AC) | |
| Rated Output Power | 10 kVA |
| Maximum Output Power | 10.5 kVA |
| Rated Output Current | 14.5 A |
| Max. Output Current | 16 A |
| Inrush Current | 31A / 100μs |
| Nominal AC Voltage | 3 Ph, 400 V |
| AC Voltage Range | 400 V ± 20 % (320~480) |
| Nominal Frequency | 50 Hz |
| Frequency Range | 45 Hz - 55 Hz |
| Power Factor at Rated Power | Unity |
| Reactive Power (Adjustable) | 0.8 Lagging ~ 0.8 Leading |
| Harmonics | <3% at Rated Power |
| DC Injection | <0.5% at Rated Output Current |
| No. of Conductors (user settable) | 4/5 Wire (L1, L2, L3, N, PE) |
| Efficiency | |
| Maximum Efficiency | 98.30% |
| Euro Efficiency | 98% |
| Protection | |
| Input-side Disconnection Device | Yes |
| Ground fault monitoring / Grid monitoring | Yes |
| DC reverse polarity protection | Yes |
| DC Over Voltage / Current Limitation Protection | Yes |
| DC Short Circuit Protection Yes, PV Fuse - 1000V, 15A AC Short Circuit Protection | Yes |
| AC Over Voltage / Current Limitation Protection | Yes |
| DC / AC Side Surge Protection – Inbuilt | Yes, MOV |
| Safety/Standards | |
| Anti-islanding Protection / Grid Regulation | VDE-AR-N 4105:2011 ; DIN VDE V 0124-100:2012; DIN VDE V 0126-1-1; IEC 61727; IEC 62116 |
| EMC | DIN VDE V 0124-100:2012; DIN VDE V |
| Safety | 0126-1-1; IEC 61727; IEC 62116 |
| Efficiency | IEC 61683:1999 |
| Environmental Testing | IEC 60068-2 (1,2,14,30) |
| Ingress Protection | IEC 60529 |
| Communication | |
| Communication Interface | MODBUS RTU over RS 485 Physical Layer |
| Display | 20 x 4 LCD |
| Built-in Energy Data Logger | Yes |
| Emergency Power Off (EPO) | Yes, External Switch to be Connected |
| Warranty | |
| Standard Warranty | 5 Years |
Graph
Product Features
With Delta's cutting-edge technology, the commercial series Solar Inverters are with efficiencies as high as 98.5%. These inverters are compact in size with durable quality to ensure smooth PV system operation. IP65 enclosure provides higher level of protection and enhances its durability in a harsh outdoor environment.
Technical Data RPI-M30A
| Input (DC) | RPI-M30A |
|---|---|
| Recommended Max. DC Power | 37.5 kWp |
| Max. Input Voltage | 1000 V |
| DC Voltage Range | 200 - 1000 V |
| Start-up Voltage | >250 V |
| Start-up Power | 40W |
| MPPT Voltage Range | 200 - 1000 V |
| MPP Voltage Range, Full Power | 520 - 800 V |
| Nominal DC Voltage | 600 V |
| Max. Input Current per MPPT | 30 A |
| Total Input Current | 60A |
| Maximum Short Circuit Current | 36A / 36A |
| No. of Independent MPP Trackers | 2 |
| Unbalanced Input (%) | 33 / 67 |
| Input Connection Type | 6 pair MC4 |
| DC Disconnection Switch | Yes (Inbuilt) |
| Output (AC) | |
| Rated Output Power | 30 kVA |
| Maximum Output Power | 33 kVA |
| Rated Output Current | 45.5 A |
| Max. Output Current | 50 A |
| Inrush Current | 150A / 100μs |
| Nominal AC Voltage | 3 Ph, 415 V |
| AC Voltage Range | 320~480 V |
| Nominal Frequency | 50 Hz |
| Frequency Range | 45 Hz - 55 Hz |
| Power Factor at Rated Power | Unity |
| Reactive Power (Adjustable) | 0.8 Lagging ~ 0.8 Leading |
| Harmonics | <3% at Rated Power |
| DC Injection | <0.5% at Rated Output Current |
| No. of Conductors (user settable) | 4/5 Wire (L1, L2, L3, N, PE) |
| Efficiency | |
| Maximum Efficiency | 0.99 |
| Euro Efficiency | 0.98 |
| Protection | |
| Input-side Disconnection Device | Yes |
| Ground fault monitoring / Grid monitoring | Yes |
| DC reverse polarity protection | Yes |
| DC Over Voltage / Current Limitation Protection | Yes |
| DC Short Circuit Protection Yes, PV Fuse - 1000V, 15A AC Short Circuit Protection | Yes |
| AC Over Voltage / Current Limitation Protection | Yes |
| DC / AC Side Surge Protection – Inbuilt | Yes, MOV |
| Safety/Standards | |
| Anti-islanding Protection / Grid Regulation | VDE-AR-N 4105; VDE0126-1-1; IEC 62116; IEC 61727 |
| EMC | EN 61000; IEC 61000 |
| Safety | IEC/EN 62109-2:2011 |
| Efficiency | IEC 61683:1999; EN 50530 (As Per MNRE and SECI Requirement) |
| Environmental Testing | IEC 60068-2 (1,2,14,30) & (6,21,27,75,78) |
| Ingress Protection | IEC 60529 Edition 2.1 2001-02 |
| Communication | |
| Communication Interface | MODBUS RTU over RS 485 Physical Layer |
| Display | 20 x 4 LCD |
| Built-in Energy Data Logger | Yes |
| Emergency Power Off (EPO) | Yes, External Switch to be Connected |
| Warranty | |
| Standard Warranty | 5 Years |
Graph
Product Features
The smallest & lightest 50 kW string inverter in the world.Delta’s latest revolutionary design “RPI-M50A” transformerless PV inverter is the lightest, smallest, and first wall mount-able 50KW string inverter in the world. With such compact size and light weight, RPI-M50A offers more design flexibility for all sizes of PV plants. IP65 enclosure provides higher level of protection and enhances its durability in a harsh outdoor environment.
Thoughtful Grip DesignErgonomic grip design gives more convenience while moving the inverter during installation. With special handle protection design, RPI-M50A can be easily placed down on the flat ground vertically without damaging various connectors at the bottom.
Built-in SPD & String FusesThe RPI-M50A comes with built in PV fuse on both the positive and negative strings for alltwelve inputs. Also the inverter has Type-2 SPD's (Surge Protection Device) for both theDC (One for each MPPT) and AC inputs. Boththe PV fuse and SPD's can be replaced. Thiscan bring down the overall PV system costing.
Outstanding PerformanceRPI-M50A comes with a peak efficiency of 98.6 %, guaranteeing better yields and returns on capital cost. The dual MPPT trackers ensure no compromise over shading losses and can accommodate PV arrays with different orientations.
Protection Features : AC / DC Safety SwitchIntegrated AC/DC switch makes maintenanceand trouble shooting easy.
Savings with RPI-M50A
Notes
Specifications
| INPUT (DC) RPI-M50A | RPI-M50A |
|---|---|
| Recommended Max. DC Power | 63kWp |
| Max. Input Voltage | 1000 V |
| DC Voltage Range | 200 - 1000 V |
| Start-up Voltage | >250 V |
| Start-up Power | 40W |
| MPPT Voltage Range | 200 - 1000 V |
| MPP Voltage Range, Full Power | 520 - 800 V |
| Nominal DC Voltage | 600 V |
| Max. Input Current per MPPT | 50 A |
| Total Input Current | 100 A |
| Maximum Short Circuit Current | 60A / 60A |
| No. of Independent MPP Trackers | 2 |
| Unbalanced Input (%) | 33 / 67 |
| Input Connection Type | 12 pair MC4 |
| DC Disconnection Switch | Yes (Inbuilt) |
| OUTPUT (AC) | |
| Rated Output Power | 50 kVA |
| Maximum Output Power | 55 kVA |
| Rated Output Current | 76 A |
| Max. Output Current | 80 A |
| Inrush Current | 200A / 100μs |
| Nominal AC Voltage | 3 Ph, 415 V |
| AC Voltage Range | 320~480 V |
| Nominal Frequency | 50 Hz |
| Frequency Range | 45 Hz - 55 Hz |
| Power Factor at Rated Power | Unity |
| Reactive Power (Adjustable) | 0.8 Lagging ~ 0.8 Leading |
| Harmonics | <3% at Rated Power |
| DC Injection | <0.5% at Rated Output Current |
| No. of Conductors (user settable) | 4/5 Wire (L1, L2, L3, N, PE) |
| EFFICIENCY | |
| Maximum Efficiency | 0.99 |
| Euro Efficiency | 0.98 |
| PROTECTION | |
| Input-side Disconnection Device | Yes |
| Ground fault monitoring / Grid monitoring | Yes |
| DC reverse polarity protection | Yes |
| DC Over Voltage / Current Limitation Protection | Yes |
| DC Short Circuit Protection Yes, PV Fuse - 1000V, 15A AC Short Circuit Protection | Yes |
| AC Over Voltage / Current Limitation Protection | Yes |
| DC / AC Side Surge Protection – Inbuilt | Yes, SPD - Type 2 |
| SAFETY/STANDARDS | |
| Anti-islanding Protection / Grid Regulation | VDE-AR-N 4105; VDE 0126-1-1; VDE V 0124; IEC 61727; IEC 62116 |
| EMC | EN 61000-6-2; EN 61000-6-4 |
| Safety | IEC 62109-1/-2 |
| EFFICIENCY | IEC 61683:1999; EN 50530 (As Per MNRE and SECI Requirement) |
| Environmental Testing | IEC 60068-2 (1,2,14,30) & (6,21,27,75,78) |
| Ingress Protection | IEC 60529 |
| COMMUNICATION | |
| Communication Interface | MODBUS RTU over RS 485 Physical Layer |
| Display | 20 x 4 LCD |
| Built-in Energy Data Logger | Yes |
| Emergency Power Off (EPO) | Yes, External Switch to be Connected |
| WARRANTY | |
| Standard Warranty | 5 Years |
| Dry Contact Relay (2 Nos.) | Yes |
Graph
PV System Comparison
Product Features
With Delta's cutting-edge technology, the commercial series Solar Inverters are with efficiencies as high as 98.3%. These inverters are compact in size with durable quality to ensure smooth PV system operation. IP65 enclosure provides higher level of protection and enhances its durability in a harsh outdoor environment.
Notes
Technical Data
| Input (DC) | RPI-M15A |
|---|---|
| Recommended Max. DC Power | 19 kWp |
| Max. Input Voltage | 1000 V |
| DC Voltage Range | 200 - 1000 V |
| Start-up Voltage | >250 V |
| Start-up Power | 40W |
| MPPT Voltage Range | 200 - 1000 V |
| MPP Voltage Range, Full Power | 355 - 820 V |
| Nominal DC Voltage | 635 V |
| Max. Input Current per MPPT | 22 A |
| Total Input Current | 44 A |
| Maximum Short Circuit Current | 24A / 24A |
| No. of Independent MPP Trackers | 2 |
| Unbalanced Input (%) | 33 / 67 |
| Input Connection Type | 4 pair MC4 |
| DC Disconnection Switch | Yes (Inbuilt) |
| Output (AC) | |
| Rated Output Power | 15 kVA |
| Maximum Output Power | 15.75 kVA |
| Rated Output Current | 22 A |
| Max. Output Current | 24 A |
| Inrush Current | 150A / 100μs |
| Nominal AC Voltage | 3 Ph, 400 V |
| AC Voltage Range | 400 V ± 20 % (320~480) |
| Nominal Frequency | 50 Hz |
| Frequency Range | 45 Hz - 55 Hz |
| Power Factor at Rated Power | Unity |
| Reactive Power (Adjustable) | 0.8 Lagging ~ 0.8 Leading |
| Harmonics | <3% at Rated Power |
| DC Injection | <0.5% at Rated Output Current |
| No. of Conductors (user settable) | 4/5 Wire (L1, L2, L3, N, PE) |
| Efficiency | |
| Maximum Efficiency | 98.30% |
| Euro Efficiency | 97.90% |
| Protection | |
| Input-side Disconnection Device | Yes |
| Ground fault monitoring / Grid monitoring | Yes |
| DC reverse polarity protection | Yes |
| DC Over Voltage / Current Limitation Protection | Yes |
| DC Short Circuit Protection Yes, PV Fuse - 1000V, 15A AC Short Circuit Protection | Yes |
| AC Over Voltage / Current Limitation Protection | Yes |
| DC / AC Side Surge Protection – Inbuilt | Yes, MOV |
| Safety/Standards | |
| Anti-islanding Protection / Grid Regulation | DIN VDE V 0124-100; DIN VDE V 0126-1- 1;VDE 4105; IEC 61727; IEC 62116 |
| EMC | EN 61000; IEC 61000 |
| Safety | IEC/EN 62109-2:2011 |
| Efficiency | IEC 61683:1999; EN 50530 (As Per MNRE and SECI Requirement) |
| Environmental Testing | IEC 60068-2 (1,2,14,30) & (6,21,27,75,78) |
| Ingress Protection | EN 60529:1991+A1:2000; IEC 60529:1989/A1:1999 |
| Communication | |
| Communication Interface | MODBUS RTU over RS 485 Physical Layer |
| Display | 20 x 4 LCD |
| Built-in Energy Data Logger | Yes |
| Emergency Power Off (EPO) | Yes, External Switch to be Connected |
| Warranty | |
| Standard Warranty | 5 Years |
Graph
Product Features
Delta RPI-M20AWith Delta's cutting-edge technology, the commercial series Solar Inverters are with efficiencies as high as 98.4%. These inverters are compact in size with durable quality to ensure smooth PV system operation. IP65 enclosure provides higher level of protection and enhances its durability in a harsh outdoor environment.
Notes
Technical Data
| Input (DC) | RPI-M20A |
|---|---|
| Recommended Max. DC Power | 25 kWp |
| Max. Input Voltage | 1000 V |
| DC Voltage Range | 200 - 1000 V |
| Start-up Voltage | >250 V |
| Start-up Power | 40W |
| MPPT Voltage Range | 200 - 1000 V |
| MPP Voltage Range, Full Power | 470 - 820 V |
| Nominal DC Voltage | 635 V |
| Max. Input Current per MPPT | 22 A |
| Total Input Current | 44 A |
| Maximum Short Circuit Current | 24A / 24A |
| No. of Independent MPP Trackers | 2 |
| Unbalanced Input (%) | 33 / 67 |
| Input Connection Type | 4 pair MC4 |
| DC Disconnection Switch | Yes (Inbuilt) |
| Output (AC) | |
| Rated Output Power | 20 kVA |
| Maximum Output Power | 21 kVA |
| Rated Output Current | 29 A |
| Max. Output Current | 32 A |
| Inrush Current | 150A / 100μs |
| Nominal AC Voltage | 3 Ph, 400 V |
| AC Voltage Range | 400 V ± 20 % (320~480) |
| Nominal Frequency | 50 Hz |
| Frequency Range | 45 Hz - 55 Hz |
| Power Factor at Rated Power | Unity |
| Reactive Power (Adjustable) | 0.8 Lagging ~ 0.8 Leading |
| Harmonics | <3% at Rated Power |
| DC Injection | <0.5% at Rated Output Current |
| No. of Conductors (user settable) | 4/5 Wire (L1, L2, L3, N, PE) |
| Efficiency | |
| Maximum Efficiency | 98.40% |
| Euro Efficiency | 98.10% |
| Protection | |
| Input-side Disconnection Device | Yes |
| Ground fault monitoring / Grid monitoring | Yes |
| DC reverse polarity protection | Yes |
| DC Over Voltage / Current Limitation Protection | Yes |
| DC Short Circuit Protection Yes, PV Fuse - 1000V, 15A AC Short Circuit Protection | Yes |
| AC Over Voltage / Current Limitation Protection | Yes |
| DC / AC Side Surge Protection – Inbuilt | Yes, MOV |
| Safety/Standards | |
| Anti-islanding Protection / Grid Regulation | DIN VDE V 0124-100; DIN VDE V 0126-1- 1;VDE 4105; IEC 61727; IEC 62116 |
| EMC | EN 61000; IEC 61000 |
| Safety | IEC/EN 62109-2:2011 |
| Efficiency | IEC 61683:1999; EN 50530 (As Per MNRE and SECI Requirement) |
| Environmental Testing | IEC 60068-2 (1,2,14,30) & (6,21,27,75,78) |
| Ingress Protection | EN 60529:1991+A1:2000; IEC 60529:1989/A1:1999 |
| Communication | |
| Communication Interface | MODBUS RTU over RS 485 Physical Layer |
| Display | 20 x 4 LCD |
| Built-in Energy Data Logger | Yes |
| Emergency Power Off (EPO) | Yes, External Switch to be Connected |
| Warranty | |
| Standard Warranty | 5 Years |
Graph
The TRIO-50.0/60.0 inverter is ABB’s three-phase string solution for cost efficient large decentralized photovoltaic systems for both commercial and utilityapplications.
The TRIO-50.0/60.0 inverter has been designed with the objective to maximize the ROI in large systems with all the advantages of a decentralizedconfiguration for both rooftop and groundmounted installations.
Modular designTRIO-50.0/60.0 has a landscape modular design to guarantee maximum flexibility. The separate and configurable AC and DCcompartments increase the ease of installation and maintenance with their ability to remain separately wired from the inverter module inside the system. The TRIO-50.0/60.0 comes with the most complete wiring box configurations available including up to 16 DC inputs with fast connectors, monitored fuses, AC and DC switches and monitored type II AC andDC surge arresters.
Flexibility of installation The forced air cooling system, designed for a simple and fast maintenance allows for the maximum flexibility of installation. The inverter comes with mounting supports for both horizontal and vertical positions which allow for the best use of space available beneath the solar panels.
Design flexibilityThe double stage conversion topology offers the advantage of a wide input voltage range for maximum flexibility of the system design.
Highlights
Technical Data And Types
| Type code | TRIO-5.8-TL-OUTD | TRIO-7.5-TL-OUTD |
|---|---|---|
| Input side | ||
| Absolute maximum DC input voltage (Vmax,abs) | 1000 V | |
| Start-up DC input voltage (Vstart) | 420...700 V (Default 420 V) | 420...700 V (Default 500 V) |
| Operating DC input voltage range (Vdcmin...Vdcmax) | 0,7xVstart ...950 V (min 300 V) | 0,7xVstart ...950 V (min 360 V) |
| Rated DC input voltage (Vdcr) | 610 Vdc | 720 Vdc |
| Rated DC input power (Pdcr) | 52000 W | 61800 W |
| Number of independent MPPT | 3 (SX and SX2 version) / 1 (standard and S version) | |
| Number of MPPT in parallel mode | 1 | |
| Maximum DC input power for each MPPT (PMPPT,max) | 17500 W | 21000 W |
| MPPT input DC voltage range (VMPPTmin ... VMPPTmax) at Pacr | 480-800 Vdc | 570-800 Vdc |
| Maximum DC input current (Idcmax) for each MPPT | 36 A | |
| Maximum input short circuit current for each MPPT | 55 A (165 A in case of parallel MPPT) | |
| Number of DC input pairs for each MPPT | 5 | |
| DC connection type | Screw terminal block (Standard and -S version) or PV quick fit connector 3) (-SX and SX2 version) |
|
| Input protection | ||
| Reverse polarity protection | Yes, from limited current source | |
| Input over voltage protection for each MPPT - varistor | Yes, 1 for each MPPT | |
| Input over voltage protection for each MPPT - plug In modular surge arrester |
Type 2 (option) with monitoring | |
| Photovoltaic array isolation control | According to local standard | |
| DC switch rating for each MPPT (version with DC switch) | 60 A / 1000 V for each MPPT (180 A in case of parallel MPPT) | |
| Fuse rating (version with fuses) | 15 A / 1000 V | |
| Output side | ||
| AC grid connection type | Three-phase (3W+PE or 4W+PE) | |
| Rated AC power (Pacr @cosφ=1 ) | 50000 W | 60000 W |
| Maximum AC output power (Pacmax @cosφ=1) | 50000 W | 60000 W |
| Maximum apparent power (Smax) | 50000 VA | 60000 VA |
| Rated AC grid voltage (Vac,r) | 400 V | 480 V |
| AC voltage range | 320...480 V 1) | 384...571 V 1) |
| Maximum AC output current (Iac,max) | 77 A | |
| Contributory fault current | 92 A | |
| Rated output frequency (fr) | 50 Hz / 60 Hz | |
| Output frequency range (fmin...fmax) | 47...53 Hz / 57…63 Hz 2) | |
| Nominal power factor and adjustable range | > 0.995; 0...1 inductive/capacitive with maximum Smax | |
| Total current harmonic distortion | <3% | |
| Maximum AC cable | 95 mm2 copper only (150 mm2 copper/alluminum with TRIO-AC-WIRING-KIT) | |
| AC connection type | Screw terminal block, cable gland | |
| Output protection | ||
| Anti-islanding protection | According to local standard | |
| Maximum external AC overcurrent protection | 100 A | |
| Output overvoltage protection - varistor | Yes | |
| Output overvoltage protection - plug In modular surge arrester | Type 2 (option) with monitoring | |
| Operating performance | ||
| Maximum efficiency (ηmax) | 98.3% - | 98.5% - |
| Weighted efficiency (EURO) | 98.0% / - | 98.0% / - |
| Communication | ||
| Embedded communication interfaces | 2x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2,4 Ghz) | |
| Communication protocols | Modbus RTU / TCP (Sunspec compliant); Aurora Protocol | |
| Remote monitoring services | Standard level access to Aurora Vision monitoring portal | |
| Advanced features | Integrated Web User Interface; Display (option); Embedded logging and direct transferring of data to Cloud |
|
| Environmental | ||
| Ambient temperature range | -25...+60°C/ -13...14°F with derating above 50°C /140°F |
-25...+60°C/-13...140°F with derating above 45°C/113°F |
| Relative humidity | 4%...100% condensing | |
| Sound pressure level, typical | 75 dB(A) @1 m | |
| Maximum operating altitude without derating | 2000 m / 6560 ft | |
| Physical | ||
| Environmental protection rating | IP65 (IP54 for cooling section) | |
| Cooling | Forced air | |
| Dimension (H x W x D) | 725 mm x 1491 mm x 315 mm / 28.5” x 58.7” x 12.4” | |
| Weight | 95 kg / 209 lbs overall, 66 kg / 145 lbs electronic compartment, 15 kg / 33 lbs AC wiring box (full optional), 14kg / 31 lbs DC wiring box (full optional) |
|
| Mounting system | Wall bracket, horizontal support | |
| Safety | ||
| Isolation level | Transformerless | |
| Marking | CE | |
| Safetyand EMC standar | IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12 |
|
| Grid standard (check your sales channel for availability) | CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, EN 50438 (not for all national appendices), RD 1699, RD 413, RD 661, P.O. 12.3, AS 4777, BDEW, NRS-097-2-1, MEA, PEA, IEC 61727, IEC 60068, IEC 61683, VFR-2014, IEC 62116 |
|
| Available products variants | ||
| Inverter power module | TRIO-TM-50.0-400-POWER MODULE | TRIO-TM-60.0-480-POWER MODULE |
| DC wiring box options 4) | ||
| Input connections with terminal blocks | DCWB-TRIO-TM-50.0-400 | DCWB-TRIO-TM-60.0-480 |
| Input connections with terminal blocks + DC switch | DCWB-S-TRIO-TM-50.0-400 | DCWB-S-TRIO-TM-60.0-480 |
| 15 quick input connections + fuses (single pole) + DC switch 5) | DCWB-SX-TRIO-TM-50.0-400 | DCWB-SX-TRIO-TM-60.0-480 |
| 15 quick input connections + fuses (both poles) + DC switch 5) | DCWB-SX2-TRIO-TM-50.0-400 | DCWB-SX2-TRIO-TM-60.0-480 |
| AC wiring box options | ||
| AC output connections with terminal blocks | ACWB-TRIO-TM-50.0 | ACWB-TRIO-TM-60.0 |
| AC output connections with terminal blocks + AC switch 5) | ACWB-SX-TRIO-TM-50.0 | ACWB-SX-TRIO-TM-60.0 |
| Optional available | ||
| TRIO-GROUNDING-KIT | Available | Available |
| TRIO-AC-WIRING-KIT | Available | Available |
ABB TRIO-TM-50.0-400 / TRIO-TM-60.0-480 String Inverter Block Diagram
With Delta's cutting-edge technology, the commercial series Solar Inverters are with efficiencies as high as 98.3%. These inverters are compact in size with durable quality to ensure smooth PV system operation. IP65 enclosure provides higher level of protection and enhances its durability in a harsh outdoor environment.
Product Features
Note : Product image shown above is indicative only. The inverter has only two pairs of MC4 connector input.
Technical Data RPI-M6A
| Input (DC) Rpi-M6a | |
|---|---|
| Recommended Max. DC Power | 7.5 kWp |
| Max. Input Voltage | 1000 V |
| DC Voltage Range | 200 - 1000 V |
| Start-up Voltage | >250 V |
| Start-up Power | 40W |
| MPPT Voltage Range | 200 - 1000 V |
| MPP Voltage Range, Full Power | 315 - 800 V |
| Nominal DC Voltage | 600 V |
| Max.Input Current per MPPT | 10 A |
| Total Input Current | 20 A |
| Maximum Short Circuit Current | 13A / 13A |
| No. of Independent MPP Trackers | 2 |
| Unbalanced Input (%) | 33 / 67 |
| Input Connection Type | 2 pair MC4 |
| DC Disconnection Switch | Yes (Inbuilt) |
| Output (AC) | |
| Rated Output Power | 6 kVA |
| Maximum Output Power | 6.3 kVA |
| Rated Output Current | 8.7 A |
| Max. Output Current | 9.7 A |
| Inrush Current | 31A / 100μs |
| Nominal AC Voltage | 3 Ph, 400 V |
| AC Voltage Range | 400 V ± 20 % (320~480) |
| Nominal Frequency | 50 Hz |
| Frequency Range | 45 Hz - 55 Hz |
| Power Factor at Rated Power | Unity |
| Reactive Power (Adjustable) | 0.8 Lagging ~ 0.8 Leading |
| Harmonics | <3% at Rated Power |
| DC Injection | <0.5% at Rated Output Current |
| No. of Conductors (user settable) | 4/5 Wire (L1, L2, L3, N, PE) |
| Efficiency | |
| Maximum Efficiency | 98.30% |
| Euro Efficiency | 97.60% |
| Protection | |
| Input-side Disconnection Device | Yes |
| Ground Fault Monitoring / Grid Monitoring | Yes |
| DC Reverse Polarity Protection | Yes |
| DC Over Voltage / Current Limitation Protection | Yes |
| AC Short Circuit Protection | Yes |
| AC Over Voltage / Current Limitation Protection | Yes |
| DC / AC Side Surge Protection - Inbuilt Yes, MOV | Yes Mov |
| General Data | RPI-M6A |
| Dimension (H/W/D) | 445 x 510 x 177 mm |
| Weight (kg) | 25 |
| Operating Temperature Range | - 25 C to + 60 C o (Full Power - 20 C to + 40 oC) |
| Relative Humidity | 0~100%, Non-condensing |
| Operating Elevation | <2000 m |
| Degree of Protection | IP65 |
| Noise Level (Typical) | <50dB (1m Front Panel) |
| Self Consumption at Night | <2 Watts |
| Safety/Standards | |
| Anti-islanding Protection / Grid Regulation |
VDE-AR-N 4105:2011 ; DIN VDE V 0124-100:2012; DIN VDE V 0126-1-1; IEC 61727; IEC 62116 |
| EMC | EN 61000; IEC 61000 |
| Safety | IEC 62109-2 |
| Efficiency | IEC 61683:1999 |
| Environmental Testing | IEC 60068-2 (1,2,14,30) |
| Ingress Protection | IEC 60529 |
| Communication | |
| Communication Interface | MODBUS RTU over RS 485 Physical Layer |
| Graphical Display | 20 x 4 LCD |
| Built-in Energy Data Logger | Yes |
| Emergency Power Off (EPO) | Yes, External Switch to be Connected |
| Warranty | |
| Standard Warranty | 5 Years |
Graph
The new UNO-DM-6.0-PLUS singlephase inverter is an upgrade of the proven UNO family and is an optimal solution for residentialinstallations.
High power densityThe new design wraps ABB’s quality and engineering into a lightweight and compact package thanks to technological choices optimized for installations with different orientation. The inverter allows high performance in a minimum space and has a dual Maximum Power Point Tracker (2 MPPT).
Easy to install, fast to commissionThe featured easy commissioning routine removes the need for a long configuration process, resulting in lower installation time and costs. Improved user experience thanks to a build in User Interface (UI), which enables access to features such as advanced inverter configuration settings, dynamic feed-in control and load manager, from any WLAN enabled devices (smartphone, tablet or PC).
Smart capabilitiesThe embedded logging capabilities and direct transferring of the data to Internet (via Ethernet or WLAN) allow customers to enjoy the whole Aurora Vision® remote monitoring experience.
The advanced communication interfaces (WLAN, Ethernet, RS485) combined with an efficient Modbus (RTU/TCP) communication protocol, Sunspec compliant, allow the inverter to be easily integrated within any smart environment and with third party monitoring and control systems.
A complete set of control functions with the embedded efficient algorithm, enabling dynamic control of the feed-in (i.e. zero injection), make the inverter suitable for worldwide applications in compliance with regulatory norms and needs of the utilities. The future-proof and flexible design enables integration with current and future devices for smart building automation.
Highlights
Technical Data And Types
| Type code | UNO-DM-6.0-TL-PLUS |
|---|---|
| Input side | |
| Absolute maximum DC input voltage (Vmax,abs) | 600 V |
| Start-up DC input voltage (Vstart) | 200 V (adj. 120...350 V) |
| Operating DC input voltage range (Vdcmin...Vdcmax) | 0.7 x Vstart...580 V (min 90 V) |
| Rated DC input voltage (Vdcr) | 360 V |
| Rated DC input power (Pdcr) | 6200 |
| Number of independent MPPT | 2 |
| Maximum DC input power for each MPPT (PMPPTmax) | 4000W |
| DC input voltage range with parallel configuration of MPPT at Pacr | 160…480V |
| DC power limitation with parallel configuration of MPPT | Linear derating from Max to 500W [480V≤VMPPT≤580V] |
| DC power limitation for each MPPT with independent configuration of MPPT at Pacr , max unbalance example |
4000 W [220V≤VMPPT≤480V] the other channel: Pdcr-4000W [120V≤VMPPT≤480V] |
| Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) | 40 A / 20.0 A |
| Maximum input short circuit current for each MPPT | 25.0 A |
| Number of DC inputs pairs for each MPPT2 | |
| DC connection type | Quick Fit PV Connector (1) |
| Input protection | |
| Reverse polarity protection | Yes, from limited current source |
| Input over voltage protection for each MPPT - varistor | Yes |
| Photovoltaic array isolation control | According to local standard |
| DC switch rating for each MPPT (version with DC switch) | 32A / 600 V |
| Output side | |
| AC Grid connection type | Single phase |
| Rated AC power (Pacr @cosφ=1 ) | 6000 W |
| Maximum AC output power (Pacmax @cosφ=1) | 6000 W |
| Maximum apparent power (Smax) | 6650 VA |
| Rated AC grid voltage (Vac,r) | 230 V |
| AC voltage range | 180...264 V (2) |
| Maximum AC output current (Iac,max) | 30.0 A |
| Contributory fault current | 40.0 A |
| Rated output frequency (fr) | 50 Hz / 60 Hz |
| Output frequency range (fmin...fmax) | 47...53 Hz / 57…63 Hz(3) |
| Nominal power factor and adjustable range | > 0.995, adj. ± 0.8 |
| Total current harmonic distortion | < 3.5 |
| AC connection type | Termilan Block |
| Output protection | |
| Anti-islanding protection | According to local standard |
| Maximum external AC overcurrent protection | 40.0 A |
| Output overvoltage protection - varistor | 2 (L - N / L - PE) |
| Operating performance | |
| Maximum efficiency (ηmax) | 97,40% |
| Weighted efficiency (EURO/CEC) | 97.0% / - |
| Feed in power threshold | 8 W |
| Night consumption | <0.4 W |
| Embedded Communication | |
| Embedded Communication Interface | Wireless(4) |
| Embedded Communication Protocol | ModBus TCP (SunSpec) |
| Commissioning Tool | Web User Interface, Display, Aurora Manger Lite |
| Monitoring | Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile |
| Optional board UNO-DM-COM kit | |
| Optional Communication Interface | RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote ON/OFF |
| Optional Communication Protocol | ModBus RTU (SunSpec), Aurora Protocol |
| Optional board UNO-DM-PLUS Ethernet COM kit | |
| Optional Communication Interface | Ethernet, RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote ON/OFF |
| Optional Communication Protocol | ModBus TCP (SunSpec), ModBus RTU (SunSpec), Aurora Protocol |
| Environmental | |
| Ambient temperature range | -25...+60°C (-13...+ 140°F) with derating above 45°C/113°F |
| Relative humidity | 0...100% condensing |
| Maximum operating altitude without derating | 2000 m / 6560 ft |
| Physical | |
| Environmental protection rating | IP 65 |
| Cooling | Natural |
| Dimension (H x W x D) | 418 mm x 553 mm x 180 mm |
| Weight | 20,5 kg |
| Mounting system | Wall bracket |
| Safety | |
| Isolation level | Transformerless |
| Marking | CE (50 Hz only), RCM |
| Safety and EMC standard | EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, EN 61000-6-1, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12 |
| Grid standard (check your sales channel for availability) | CEI 0-21, DIN V VDE V 0126-1-1, ITC-BT-40, AS 4777, INMETRO Ordinances 357-2014 |
| Available products variants | |
| Standard | UNO-DM-6.0-TL-PLUS-B |
| With DC switch | UNO-DM-6.0-TL-PLUS-SB |
ABB UNO-DM-6.0-TL-PLUS String Inverter Block Diagram
The new UNO-DM-PLUS singlephase inverter family, with power ratings from 3.3 to 5.0 kW, is the optimal solution for residentialinstallations
One size fits allThe new design wraps ABB’s quality and engineering into a lightweight and compact package thanks to technological choices optimized for installations withdifferent orientation. All power ratings share the same overall volume, allowing higher performance in a minimum space, and have a dual Maximum Power Point Tracker (2 MPPT).
Easy to install, fast to commissionThe presence of plug and play connectors, both on the DC and AC side, as well as the wireless communication, enable a simple, fast and safe installation without the need of opening the frontcover of the inverter.
The featured easy commissioning routine removes the need for a long configuration process, resulting in lower installation time and costs. Improved user experience thanks to a build in UserInterface (UI), which enables access to features such as advanced inverter configuration settings, dynamic feed-in control and load manager, from any WLAN enabled devices (smartphone, tablet or PC).
Smart capabilitiesThe embedded logging capabilities and direct transferring of the data to Internet (via Ethernet or WLAN) allow customers to enjoy the whole Aurora Vision® remote monitoring experience.
The advanced communication interfaces (WLAN, Ethernet, RS485) combined with an efficient Modbus (RTU/TCP) communication protocol, Sunspec compliant, allow the inverter to be easily integrated within any smart environment and with third party monitoring and control systems.
A complete set of control functions with the embedded efficient algorithm, enabling dynamic control of the feed-in (i.e. zero injection), make the inverter suitable for worldwide applications incompliance with regulatory norms and needs of the utilities.
The future-proof and flexible design enables integration with current and future devices for smart building automation.
Highlights
Technical Data And Types
| Type code | UNO-DM-3.3-TL-PLUS | UNO-DM-4.0-TL-PLUS | UNO-DM-4.6-TL-PLUS | UNO-DM-5.0-TL-PLUS |
|---|---|---|---|---|
| Input side | ||||
| Absolute maximum DC input voltage (Vmax,abs) |
600 V | |||
| Start-up DC input voltage (Vstart) |
200 V (adj. 120...350 V) | |||
| Operating DC input voltage range (Vdcmin...Vdcmax) |
0.7 x Vstart...580 V (min 90 V) | |||
| Rated DC input voltage (Vdcr) | 360 V | |||
| Rated DC input power (Pdcr) | 3500 W | 4250 W | 4750 W | 5150 W |
| Number of independent MPPT | 2 | |||
| Maximum DC input power for each MPPT (PMPPTmax) |
2000 W | 3000 W | 3000 W | 3500 W |
| DC input voltage range with parallel configuration of MPPT at Pacr |
170...530 V | 130...530 V | 150...530 V | 145...530 V |
| DC power limitation with parallel configuration of MPPT |
Linear derating from Max to Null [530V≤VMPPT≤580V] | |||
| DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example |
2000 W [200 V≤VMPPT≤530 V] the other channel: Pdcr-2000 W [112 V≤VMPPT≤530 V |
3000 W [190 V≤VMPPT≤530 V] the other channel: Pdcr-3000 W [90 V≤VMPPT≤530 V] |
3000 W [190 V≤VMPPT≤530 V] the other channel: Pdcr-3000 W [90 V≤VMPPT≤530 V] |
3500 W [200 V≤VMPPT≤530 V] the other channel: Pdcr-3500 W [90 V≤VMPPT≤530 V] |
| Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) |
20.0 / 10.0 | 32.0 / 16.0 A | 32.0 / 16.0 A | 38.0 / 19.0 A |
| Maximum input short circuit current for each MPPT |
12.5 | 20 | 20 | 22 |
| Number of DC input pairs for each MPPT |
1 | |||
| DC connection type 1) | Quick Fit PV Connector | |||
| Input protection | ||||
| Reverse polarity protection | Yes, from limited current source | |||
| Input over voltage protection for each MPPT-varistor |
Yes | |||
| Photovoltaic array isolation Control |
According to local standard | |||
| DC switch rating for each MPPT (version with DC switch) |
25 A / 600 V | |||
| Output side | ||||
| AC grid connection type | Single-phase | |||
| Rated AC power (Pacr @cosφ=1 ) | 3300 W | 4000 W | 4600 W | 5000 W |
| Maximum AC output power (Pacmax @cosφ=1) |
3300 W | 4000 W 2) | 4600 W | 5000 W |
| Maximum apparent power (Smax) | 3300 VA | 4000 VA 2) | 4600 VA | 5000 VA |
| Rated AC grid voltage (Vac,r) | 230 V | |||
| AC voltage range 3) | 180...264 V | |||
| Maximum AC output current (Iac,max) |
14.5 A | 17.2 A | 20.0 A | 22.0 A |
| Contributory fault current | 16.0 A | 19.0 A | 22.0 A | 24.0 A |
| Rated output frequency (fr) 4) | 50/60 Hz | |||
| Output frequency range (fmin...fmax) 4) |
47...53/57...63 Hz | |||
| Nominal power factor and adjustable range |
> 0.995, adj. ± 0.1 - 1 (over/under excited) | |||
| Total current harmonic Distortion' |
< 3.5 | |||
| AC connection type | Female connector from panel | |||
| Output protection | ||||
| Anti-islanding protection | According to local standard | |||
| Maximum external AC overcurrent protection |
20.0 A | 25.0 A | 25.0 A | 32.0 A |
| Output overvoltage protection - varistor |
2 (L - N / L - PE) | |||
| Operating performance | ||||
| Maximum efficiency (ηmax | 0.97 | 0.97 | 0.97 | 0.97 |
| Weighted efficiency (EURO/CEC) | 96.5% / - | 96.5% / - | 96.5% / - | 97.0% / - |
| Feed in power threshold | 8 W | |||
| Night consumption | <0.4 W | |||
| Embedded communication | ||||
| Embedded communication interface 5) | Wireless | |||
| Embedded communication protocol | ModBus TCP (SunSpec) | |||
| Commissioning tool | Web User Interface, Display, Aurora Manager Lite | |||
| Monitoring | Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile | |||
| Optional board UNO-DM-COM kit | - | |||
| Optional communication interface | RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote ON/OFF |
|||
| Optional communication protocol | ModBus RTU (SunSpec), Aurora Protocol | |||
| Optional board UNO-DM-PLUS Ethernet COM kit |
- | |||
| Optional communication interface | Ethernet, RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote ON/OFF |
|||
| Optional communication protocol | ModBus TCP (SunSpec), ModBus RTU (SunSpec), Aurora Protocol | |||
| Environmental | ||||
| Ambient temperature range | 25...+60°C /-13...140°F with derating above 50°C/122°F |
-25...+60°C /-13...140°F with derating above 50°C/122°F |
-25...+60°C /-13...140°F with derating above 45°C/113°F 6) |
-25...+60°C /-13...140°F with derating above 45°C/113°F |
| Relative humidity | 0...100 % condensing | |||
| Maximum operating altitude without Derating |
2000 m / 6560 ft | |||
| Physical | ||||
| Environmental protection rating | IP 65 | |||
| Cooling | Natural | |||
| Dimension (H x W x D) | 553 x 418 x 175 mm / 21.8” x 16.5” x 6.9” | |||
| Weight | 15 kg / 33 lbs | |||
| Mounting system | Wall bracket | |||
| Safety | ||||
| Isolation level | Transformerless | |||
| Marking | CE , RCM | |||
| Safety and EMC standard | IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12 |
|||
| Grid standard (check your sales channel for availability) 7) |
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, RD 413, ITC-BT-40, AS/NZS 4777.2, C10/11, IEC 61727, IEC 62116 |
|||
| Available products variants | ||||
| Standard | UNO-DM-3.3-TL-PLUS-B | UNO-DM-4.0-TL-PLUS-B | UNO-DM-4.6-TL-PLUS-B | UNO-DM-5.0-TL-PLUS-B |
| With DC switch | UNO-DM-3.3-TL-PLUS-SB | UNO-DM-4.0-TL-PLUS-SB | UNO-DM-4.6-TL-PLUS-SB | UNO-DM-5.0-TL-PLUS-SB |
ABB UNO-DM-3.3/4.0/4.6/5.0-TL-PLUS String Inverter Block Diagram
Datasheet for more popular models
Special features
Specifications
| Popular Products - SMA Tripower Series Input DC | ||||
|---|---|---|---|---|
| Model | 5000 TL | 10000 TL | 20000 TL | Tripower 60 |
| Max. DC power | 5100 Wp | 10250 Wp | 20440 Wp | 61240 Wp |
| Maximum input voltage | 1000 V | 1000 V | 1000 V | 1000 V |
| MPP input voltage | 245 - 800 V | 440 - 800 V | 320 - 800 V | 570 - 800 V |
| Max. current per string | 11A / 10A | 18A / 10A | 33A / 33A | 110A / 150A |
| Output AC | ||||
| Model | 5000 TL | 10000 TL | 20000 TL | 60000 TL |
| Nominal power (apparent) | 5000 VA | 10000 VA | 20000 VA | 60000 VA |
| Frequency range | 45 - 65 Hz | 45 - 65 Hz | 45 - 65 Hz | 45 - 65 Hz |
Application Suitable for Personal Computers, DeskJet Printer, Television, Fan, Tube light, CFL, Iron, hand mixer etc. How it is different from the products of other manufacturer
Key Features
Weight And Dimensions
| Model | 650 VA | 850 VA | 1000 VA |
|---|---|---|---|
| With Packaging L x W x H (in mm) | 345x328x185 | 345x328x185 | 345x328x185 |
| Without Packaging L x W x H (in mm) | 275x250x110 | 275x250x110 | 275x250x110 |
| Net Weight | 8.6Kg | 9.5Kg | 9.9Kg |
| Gross Weight | 9.5Kg | 10.3Kg | 10.7Kg |
Load Chart
| Load Type | 650 VA | 850 VA | 1000 VA | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Tv (LCD 26") | 1 | 0 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 0 | 1 | 1 |
| Tubelight (40) | 2 | 3 | 0 | 2 | 3 | 4 | 0 | 3 | 5 | 4 | 0 | 3 |
| Cfl (15W) | 4 | 1 | 0 | 2 | 5 | 2 | 0 | 3 | 3 | 3 | 0 | 3 |
| Fan (80) | 3 | 4 | 0 | 2 | 4 | 5 | 0 | 3 | 5 | 6 | 0 | 3 |
| Computers (TFT) | 0 | 0 | 4 | 1 | 0 | 0 | 5 | 1 | 0 | 0 | 6 | 2 |