Our Products
Our product range contains a wide range of on-line ups and Modular UPS
UPS system today has come a long way from the type it was introduced in 80s. Technological Developments have brought newer and better concepts in the field. The latest trend is that of PWM technology using IGBT.ASEEM-OORJAhas incorporated advanced technology in the field. Micro Controller is used to control the processes such as pure Sine Wave generation, Alarms and Indications, Shut Down characteristics and protections.
Starting from 1 KVA to 30KVA single phase output systems and 10KVA to 500KVA 3 phase output systems are available.
The after Sales Service is our strong feature. We believe that Good Service retains customers and that Customer Retained is Customer Gained.ASEEM-OORJAthe trusted brand of the an iso certified company in the field of UPS since 1990s. Unmatched performance, with latest technology gives you a superior edge against vagaries of power. Best known UPS for critical load application, ASEEM-OORJAIs also known for prompt after sales service
| State of an art design | Wide input window | ||
| Latest IGBT Technology | Isolated O/P | ||
| Pure Sine wave O/P | User friendly Design | ||
| High MTBF | RS232 interface & SNMP Optional |
|
TECHNOLOGY |
SINE PWM WITH IGBT & LCD/LED DISPLAY |
|
|
CAPACITIES |
2 KVA TO 30 KVA WITH BUILT-IN ISOLATION |
|
|
I N P U T |
WINDOW |
170VAC-270VAC (1PH), 300-460VAC (3PH) |
|
DC BUS |
48VDC TO 360VDC |
|
|
EFFICIENCY |
BETTER THAN 85% AC-IN-AC-OUT |
|
|
INTERFACE |
AUTO SHUT DOWN SOFTWARE. [SNMP INTERFACE OPTIONAL] |
|
|
O U T P U T |
VOLTAGE |
230VAC ± 1%, 50Hz ± 0·1% (CRYSTAL CONTROLLED) |
|
OUTPUT P/F |
0·8 LAGGING TO UNITY |
|
|
TRANSIENT RESPONSE |
O/P OVERSHOOT & UNDERSHOOT LESS THAN 5% @100% LOAD CHANGE. |
|
|
DISTORTION |
LESS THAN 2% FOR LINEAR LOAD & LESS THAN 5% FOR NON LINEAR LOAD |
|
|
CREST FACTOR |
4:1 |
|
|
WAVEFORM |
PURE SINE WAVE |
|
|
INVERTER EFFICIENCY |
BETTER THAN 90% |
|
|
GENSET COMPATIBILITY |
COMPATIBLE TO GENSET OF ANY MAKE |
|
|
PROTECTIONS |
1. O/P OVERLOAD, 2. O/P SHORT CKT, 3. O/P OVER VOLTAGE, 4. BATTERY LOW |
|
|
COOLING |
FORCED AIR COOLING |
|
|
INDICATIONS |
1. MAINS/CHARGER ON, 2. INV ON, 3. SYSTEM OVERLOAD, 4. BATTERY LOW |
|
|
WORKING CONDITIONS |
0 TO 45°C, HUMIDITY 95%RH ( NON-CONDENSING) |
|
| Topology Construction |
True Online, Double Conversion Modular Parallel Hot-Plugged Module, Continuous Operation |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| INPUT | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Voltage Voltage Range Current Frequency Power Factor THDI |
3 X 400V + N -20% and + 15% 15A per for a single module, no inrush current at startup 47 - 63 Hz 0.99 5% |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| OUTPUT | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Rated Power Frequency Tracking Range Frequency (in free-running mode) Slew Rate Voltage Static Regulation Regulation for Unbalanced Load Dynamic Response to 100% Load Step Overload Waveform THD Load Creast Factor AC-AC Efficiency (nominal) DC-AC Efficiency (nominal) |
10KVA / 8 KW to 100KVA / 80kW ±1, ±2, ±3Hz (selectable) 50/60Hz ±0.1% 1Hz/sec. 3 x 400 + N ±1% 1% for 100% Unbalance load ±2% 110% for 10 min.; 125% for 60 sec.; 1000% for 1 cycle Sinusoidal Less than 2% for linear load 3:1 Up to 96% Up to 98% |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| BATTERIES | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DC-Link Voltage No. of Batteries |
±340 to 425V 64 X 12V |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| GENERAL | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Maximum Power dissipation (Po=8kw) Ambient Temperature Relative Humidity Altitude Enclosure Cooling |
333W (1136 BTU) for a single module -100C to +400C (operating) - 200C to + 600C (storage) 95% max non-condensing 1500m w/o derating IP20 Forced - Multi - Fan with speed control |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| STANDARDS | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| EMC emission EMC Immunity Safety Design Low Magnetic Field Radiation |
EN50091-2 Class A; IEC 62040-2 EN50082-2 E50091-1; IEC 62040-1-1 EN50091-3; IEC 62040-3 EMF as per ICNIRP |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DIMENSION | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 10KVA Module (H X W X D) Weight |
88MM (2U) X 483MM (19") X 455MM 9Kg |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| POWER+ System (including STSW and STSW + Base modules) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||