Our Product / Services
Our Complete range of products are Clean Agent Type Fire Extinguisher, Water Type Fire Extinguisher, Co2 Type Fire Extinguisher, Abc Type Fire Extinguisher and Mechanical Foam Type Fire Extinguisher.
Safety First ISI mark Suitable for A, B, C Class of Fire AFETY FIRST Available in capacity 500 gms., 1 kg. 2 kgs, 5 kgs, 10 kgs. Welded cylinder as well as seamless Cylinders are available HFC OR HCFC Based Clean agent gases.
"Safety First "s clean agent fire extinguisher is an excellent option to protect high value property that can be found in applications such as
Technical Specification
| Fire Extinguisher Capacity | 1 Kg | 2 Kg | 4 Kg | 6 Kg |
|---|---|---|---|---|
| Minimum Period for Which | ( IS-16018) | ( IS-15683) | ( IS-15683) | ( IS-15683) |
| Throw of Jet Maintained | 8 Sec | 8 Sec | 16 Sec | 20 Sec |
| At Least 90% of Contests | 10 Sec | 16 Sec | 20 Sec | 25 Sec |
| Range of Jet | 1 Mtr. | 1 Mtr. | 2 Mtr. | |
| Empty Wt. (Approx) | 1.2 Kg | 2.3 Kg | 2.75 Kg | 3.3 Kg |
| Full Wt. (Approx) | 2.2 Kg | 4.3 Kg | 6.75 Kg | 9.3 Kg |
| Fire Rating | 8B | 13B | 1A,21B | 1A, 34B |
| Working Pressure | 15 KGF/Cm2 | 15 KGF/Cm2 | 15 KGF/Cm2 | 15 KGF/Cm2 |
| Hydro Pressure | 35 KGF/Cm2 | 35 KGF/Cm2 | 35 KGF/Cm2 | 35 KGF/Cm2 |
| Brusting Pressure | 55 KGF/Cm2 | 55 KGF/Cm2 | 55 KGF/Cm2 | 55 KGF/Cm2 |
ISI mark water type fire extinguisher provides safety against "A" class of fire which involves materials like wood, paper, cloth, plastic & fiber, Rubber etc.
Technical Specification
| Fire Extinguisher Capacity | 6 Ltr. | 9 Ltr. | 45 Ltr. | 9 Ltr. |
|---|---|---|---|---|
| Minimum Period for Which | Stored Pressure | Stored Pressure | Catridg Type | Catridg Type |
| Throw of Jet Maintained | 25 Sec | 100 Sec | 60 Sec | 60 Sec |
| At Least 90% of Contests | 60 Sec | 120 Sec | 180 Sec | 180 Sec |
| Range of Jet | 4 Mtr. | 6 Mtr. | 10 Mtr. | 10 Mtr. |
| Empty Wt. (Approx) | 3.2 Kg | 5.35 Kg | 35 Kg | 35 Kg |
| Full Wt. (Approx) | 9.2 Kg | 14.35 Kg | 80 Kg | 80 Kg |
| Fire Rating | 3A | 3A | NA | 3A |
| Working Pressure | 15 KGF/Cm2 | 15 KGF/Cm2 | 15 KGF/Cm2 | 15 KGF/Cm2 |
| Hydro Pressure | 35 KGF/Cm2 | 35 KGF/Cm2 | 30 KGF/Cm2 | 30 KGF/Cm2 |
| Brusting Pressure | 55 KGF/Cm2 | 55 KGF/Cm2 | 45 KGF/Cm2 | 45 KGF/Cm2 |
Safety First ISI mark carbon dioxide type fire extinguisher are suitable for B & C Class of fires involving all flammable liquids, gases, live & delicate, Machinery Fires, Electrical & sophisticated electronic equipments fires transformer & switch gear fire. This extinguisher is approved by explosive Department, Govt. of India, Nagpur. The new CO2 squeeze grip type portable fire extinguisher from Safety First is also available.
Technical Specification
| Fire Extinguisher Capacity | 2 Kg | 3 Kg | 4.5 Kg | 6.5 Kg | 9 Kg | 22.5 Kg |
|---|---|---|---|---|---|---|
| Minimum Period for Which | ( IS-15683) | ( IS-15683) | ( IS-15683) | ( IS-16018) | ( IS-16018) | ( IS-16018) |
| Throw of Jet Maintained | 8 Sec | 8 Sec | 8 Sec | 10 Sec | 15 Sec | 20 Sec |
| At Least 90% of Contests | 10 Sec | 16 Sec | 20 Sec | 20 Sec | 36 Sec | 60 Sec |
| Range of Jet | 2 Mtr. | 3 Mtr. | 3 Mtr. | 4 Mtr. | 4 Mtr. | 4 Mtr. |
| Empty Wt. (Approx) | 6.2 Kg | 9.5 Kg | 12.5 Kg | 20 Kg | 26 Kg | 43.5 Kg |
| Full Wt. (Approx) | 8.2 Kg | 12.5 Kg | 17 Kg | 26.5 Kg | 35 Kg | 66 Kg |
| Fire Rating | 13B | 21B | 21B | NA | NA | NA |
| Working Pressure | 60 KGF/Cm2 | 60 KGF/Cm2 | 60 KGF/Cm2 | 60 KGF/Cm2 | 60 KGF/Cm2 | 60 KGF/Cm2 |
| Hydro Pressure | 250 KGF/Cm2 | 250 KGF/Cm2 | 250 KGF/Cm2 | 250 KGF/Cm2 | 250 KGF/Cm2 | 250 KGF/Cm2 |
| Brusting Pressure | 600 KGF/Cm2 | 600 KGF/Cm2 | 600 KGF/Cm2 | 600 KGF/Cm2 | 600 KGF/Cm2 | 600 KGF/Cm2 |
Safety First ISI mark ABC Type fire extinguisher covers A, B, C class of fires which includes Papers, Wood, Cloth, Rubber, Plastic & inflammable liquid like oil, Petrol, Paints, Petrochemical Product, Resins, Gases in the compressed Form like Oxygen, Acetylenes, LPG & CNG, Electrical & Sophisticated electrical equipments.
Technical Specification
| Fire Extinguisher Capacity | 1 Kg | 2 Kg | 4 Kg | 6 Kg | 9 Kg |
|---|---|---|---|---|---|
| Minimum Period for Which | (IS-15683) | (IS-15683) | (IS-15683) | (IS-15683) | (IS-15683) |
| Throw of Jet Maintained | 8 Sec | 8 Sec | 16 Sec | 20 Sec | 25 Sec |
| At Least 90% of Contests | 12 Sec | 16 Sec | 20 Sec | 25 Sec | 30 Sec |
| Range of Jet | 2 Mtr. | 3 Mtr. | 4 Ltr. | 6 Ltr. | 7 Ltr. |
| Empty Wt. (Approx) | 1 Kg | 1.5 Kg | 2.75 Kg | 3.3 Kg | 5.35 Kg |
| Full Wt. (Approx) | 2 Kg | 3.5 Kg | 6.75 Kg | 9.3 Kg | 14.35 Kg |
| Fire Rating | 1A, 8B | 1A, 8B | 2A, 21B | 3A, 34B | 3A, 34B |
| Working Pressure | 15 KGF/Cm2 | 15 KGF/Cm2 | 15 KGF/Cm2 | 15 KGF/Cm2 | 15 KGF/Cm2 |
| Hydro Pressure | 35 KGF/Cm2 | 35 KGF/Cm2 | 35 KGF/Cm2 | 35 KGF/Cm2 | 35 KGF/Cm2 |
| Brusting Pressure | 55 KGF/Cm2 | 55 KGF/Cm2 | 55 KGF/Cm2 | 55 KGF/Cm2 | 55 KGF/Cm2 |
Safety First ISI mark foam type fire extinguisher is designed to extinguish A & B class of fire involving wood, paper, cloth, textile, stationery, flammable & volatile liquids like oil, petrol. kerosene, solvent & chemical, wax, resins etc.
Technical Specification
| Fire Extinguisher Capacity | 6 Ltr. | 9 Ltr. |
|---|---|---|
| Minimum Period for Which | Stored Pressure | Stored Pressure |
| Throw of Jet Maintained | 35 Sec | 35 Sec |
| At Least 90% of Contests | 25 Sec | 60 Sec |
| Range of Jet | 6 Mtr. | 3 Mtr. |
| Empty Wt. (Approx) | 3.2 Kg | 5.35 Kg |
| Full Wt. (Approx) | 9.2 Kg | 14.35 Kg |
| Fire Rating | 2A, 34B | 3A, 34B |
| Working Pressure | 15 KGF/Cm2 | 15 KGF/Cm2 |
| Hydro Pressure | 35 KGF/Cm2 | 35 KGF/Cm2 |
| Brusting Pressure | 55 KGF/Cm2 | 55 KGF/Cm2 |
Safety First ISI mark Components: ABC Dry powder, Dry chemical powder, Clean Agent etc. . Applicability : For Widespread Occupancies & Storage areas Like: Storage of Flammable & Combustible Liquids & Gases, Chemicals and Grain Mill Products, Solid Fuels, Libraries Records, Museums, Showrooms, Shops, Office, Residential Premises, Workshop, Radio Rooms, T. V. Station etc. . Obtainable in Capacity: 2 kg, 5kg, 10kg, & 15kg.
Technical Specification
| Fire Extinguisher Capacity | 2 Kg | 5 Kg | 10 Kg | 15 Kg |
|---|---|---|---|---|
| Working Pressure( In KGF/Cm2) | 7 to 15 | 7 to 15 | 7 to 15 | 7 to 15 |
| Propellent | Nitrogen | Nitrogen | Nitrogen | Nitrogen |
| Area Protection in M2 | 1-1.5 | 3.5-4 | 7-8 | 8-10 |
| Hanging Vertically Above Risk | 1.5m | 1.5-2 m | 1.75-2.25m | 2-3m |
| Operation Time in Second | 8-10 | 10-15 | 15-20 | 18-23 |