Post Buy Requirement
BE
Ahmedabad, Gujarat, India
Add Review

Wires #5844240

Braided Wire

Applications :

Is suitable for interconnection of electrical measuring devices to Instrument panel or instrument. Measuring, monitoring and control in machine tool manufacturing, in plant engineering, in all places where electrical interference fields can distort a signal transmission or where Interference pulses arising in the mains must be confined.Technical Data : Special PVC data cables, adapted to DIN VDE 0245 The material used in manufacture is cadmium free and contains no silicone and free of substances harmful to the wetting properties of Lacquers.

Coupling Resistance :

< 250 ohm

Temperature Range :

Flexing -5 C to +80 C

Nominal Voltage :

Uo / 500 V

Test Voltage :

3000 V.

Insulation Resistance :

Min. 20 Mohm x km

Mutual Capacitance :

According to different cross sections Core / Core approx, 150 nF / km. Core / Screen approx, 270 nF / km

Minimum Bending Radius :

Approx. 10 x cable

Cable Structure :

Bare copper, fine wire conductors, bunch 0 0 Fixed Installation -20 C to +80 C stranded to IS 8130 class 5 and IEC 60228 class 5. Core insulation of special PVC Type A IS 5831, TI 1 DIN VDE 0207 Part 4. Coloured cores upto 4 cores only. Continuous numbering in white and one green / yellow core from 5 core onwards. Cores stranded in layers with optimal lay-length. Core Wrapping withcopper mylartape. Tinned copper braided screen, Approx. 85% coverage. Special PVC outer sheath TYPE ST1 of IS 5831, TM2 DIN VDE 0281 Part 1 and HD 21.1, sheath colour grey. Extensively Oil Resistant, Chemical Resistant. PVC self- extinguishing and flame retardant, test according to IS 694, DINVDE 0472 Part 804 and IEC 60332-1

View Complete Details

Flexible Wire

Conductor :

Compactly bunched, electrolytic grade, annealed copper with high flexibility according to class 5 conductor as per IS 8130 sizes from 0.5 sq. mm to 50.0 sq. mm.

Colours :

Black & Grey. White available on request.

Packing :

100 mtr. coils. Longer lengths can be made available on request.

View Complete Details

FR WIRE

Applications :

Suitable for use in conduit and for fixed, protected installation.

Conductor :

Many thin strands of Electrolytic Copper are fine drawn simultaneously for uniformity of Resistance, Dimension, and Flexibility. The drawn strands are twisted in high precision machines which imparts circularity to the conductor.

Insulation :

Specially formulated Lead free + Flame retardant PVC insulation is used. The FR (flame retardant) property retards the propagation of flame without compromising safety.

Insulation Conformity :

IS 5831 Type A, FR

Approvals :

IS 694 marked, FIA/TAC approved CM/L 7205255

Marking :

The cables are printed with generic marking SUPEREX-FR

Colours :

Red, Yellow, Blue, Black, Green, Grey.

Packing :

90 mtrs. coils packed in protective cartons. Project coils of 180 mtrs also available.

View Complete Details

Telephone Wire

Description

Low Attenuation and Minimised Cross Talk Flame Retardant Jacket

Application

Recommended for switchboard and telephone wiring in residentials and commercial infrastructure, for transmission of analog and digital signals, wiring in faxes, modems, alarm enunciators, data recording/acquisition systems and various communication devices.

Specifications

  • Specifications : ITD-S/WS 113C
  • Conductor : The central conductor is made of solid electrolytic grade of copper
  • Insulation : Premium quality grade polyethylene used on a special extruder. This serves for low
  • attenuation and minimised cross talk.
  • Twisted Pairs : The cores are carefully twisted with suitable lays and bunched together
  • Marking : The cables are marked RATNACOM FR
  • Packing : Available in 100 mtr. length in polybag. Higher lengths available on special request.
View Complete Details

Flat Wire

Application

The PVC insulated and sheathed 3 core flat cables are mainly used in pump connections. They are also used in many industrial applications.The sheath is specially made out to resist tough and difficult condition of usage, excellent resistant to water, conditionally resistant towater and grease.

Specifications

Approvals : IS 694 marked, FIA/TAC
Conductor : Electrolytic grade annealed copper
Core Colour : Red, yellow (centre core), blue
Sheath Colour : Black
Packing : Standard packing of 100 mtr. in coils. Longer length available on request.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Wires from Ahmedabad, Gujarat by BHUMI ELECTRICALS
Post Buy Requirement
BE
Ahmedabad, Gujarat, India
Add Review

Wires #5844240

Braided Wire

Applications :

Is suitable for interconnection of electrical measuring devices to Instrument panel or instrument. Measuring, monitoring and control in machine tool manufacturing, in plant engineering, in all places where electrical interference fields can distort a signal transmission or where Interference pulses arising in the mains must be confined.Technical Data : Special PVC data cables, adapted to DIN VDE 0245 The material used in manufacture is cadmium free and contains no silicone and free of substances harmful to the wetting properties of Lacquers.

Coupling Resistance :

< 250 ohm

Temperature Range :

Flexing -5 C to +80 C

Nominal Voltage :

Uo / 500 V

Test Voltage :

3000 V.

Insulation Resistance :

Min. 20 Mohm x km

Mutual Capacitance :

According to different cross sections Core / Core approx, 150 nF / km. Core / Screen approx, 270 nF / km

Minimum Bending Radius :

Approx. 10 x cable

Cable Structure :

Bare copper, fine wire conductors, bunch 0 0 Fixed Installation -20 C to +80 C stranded to IS 8130 class 5 and IEC 60228 class 5. Core insulation of special PVC Type A IS 5831, TI 1 DIN VDE 0207 Part 4. Coloured cores upto 4 cores only. Continuous numbering in white and one green / yellow core from 5 core onwards. Cores stranded in layers with optimal lay-length. Core Wrapping withcopper mylartape. Tinned copper braided screen, Approx. 85% coverage. Special PVC outer sheath TYPE ST1 of IS 5831, TM2 DIN VDE 0281 Part 1 and HD 21.1, sheath colour grey. Extensively Oil Resistant, Chemical Resistant. PVC self- extinguishing and flame retardant, test according to IS 694, DINVDE 0472 Part 804 and IEC 60332-1

View Complete Details

Flexible Wire

Conductor :

Compactly bunched, electrolytic grade, annealed copper with high flexibility according to class 5 conductor as per IS 8130 sizes from 0.5 sq. mm to 50.0 sq. mm.

Colours :

Black & Grey. White available on request.

Packing :

100 mtr. coils. Longer lengths can be made available on request.

View Complete Details

FR WIRE

Applications :

Suitable for use in conduit and for fixed, protected installation.

Conductor :

Many thin strands of Electrolytic Copper are fine drawn simultaneously for uniformity of Resistance, Dimension, and Flexibility. The drawn strands are twisted in high precision machines which imparts circularity to the conductor.

Insulation :

Specially formulated Lead free + Flame retardant PVC insulation is used. The FR (flame retardant) property retards the propagation of flame without compromising safety.

Insulation Conformity :

IS 5831 Type A, FR

Approvals :

IS 694 marked, FIA/TAC approved CM/L 7205255

Marking :

The cables are printed with generic marking SUPEREX-FR

Colours :

Red, Yellow, Blue, Black, Green, Grey.

Packing :

90 mtrs. coils packed in protective cartons. Project coils of 180 mtrs also available.

View Complete Details

Telephone Wire

Description

Low Attenuation and Minimised Cross Talk Flame Retardant Jacket

Application

Recommended for switchboard and telephone wiring in residentials and commercial infrastructure, for transmission of analog and digital signals, wiring in faxes, modems, alarm enunciators, data recording/acquisition systems and various communication devices.

Specifications

  • Specifications : ITD-S/WS 113C
  • Conductor : The central conductor is made of solid electrolytic grade of copper
  • Insulation : Premium quality grade polyethylene used on a special extruder. This serves for low
  • attenuation and minimised cross talk.
  • Twisted Pairs : The cores are carefully twisted with suitable lays and bunched together
  • Marking : The cables are marked RATNACOM FR
  • Packing : Available in 100 mtr. length in polybag. Higher lengths available on special request.
View Complete Details

Flat Wire

Application

The PVC insulated and sheathed 3 core flat cables are mainly used in pump connections. They are also used in many industrial applications.The sheath is specially made out to resist tough and difficult condition of usage, excellent resistant to water, conditionally resistant towater and grease.

Specifications

Approvals : IS 694 marked, FIA/TAC
Conductor : Electrolytic grade annealed copper
Core Colour : Red, yellow (centre core), blue
Sheath Colour : Black
Packing : Standard packing of 100 mtr. in coils. Longer length available on request.

View Complete Details