Industrial Air Conditioner & Devices #3632634

HUMID-BM Respiratory Humidifier

  • Model HUMID-BM
  • Power Supply 220VAC+22V, 50+1Hz
  • Flow Setting Range Low Flow Mode 2-25L/Min temp 34t, High Flow Mode - 10-80L/Min
  • Temperature Control 31oc, 34oc, 37oc
  • Oxygen/% Measure 21%-100%
  • Fio2 Control Manual titration control
  • Alarm Parameters Low oxygen concentration alarm, High oxygen concentration alarm, Ambient temp alarm
  • Recommended Ambient Temp 18oc-28oc
  • Standards IEC/EN 6060-1, IEC/EN 60601-1-2;1S08185
  • Package L330xW245xH315mm
  • Application Hospital

Product Introduction : HiFent  nasal high flow, provide higher flow rate than conventional oxygen treatment during high flow oxygen therapy and process, ideal solution for offering FiO2 that can be manual titration controled, mixed gas with controlled temperature and humidity , so as to achieve better airway management and raise the level of oxygenation.  

Applicable department : Respiratory medicine, various ICU, emergency room, neurology, neurosurgery, paediatrics (weight >3kg), rehabilitation , wards for high-ranking officials and so on.

Clinical applications : For patients with spontaneous breathing, have a respiratory treatment by setting concentration, setting flow rate and offering the gas of warming humidity.Cannot be used for life support.

Main features :

  • It provides mixed gas with high flow rate, high FiO2 and nearly 100% relative humidity, so as to achieve the following effects.
  • Keep a stable and high FiO2 , improve the effective ventilation of alveoli.
  • Reduce the dead space of nasopharynx, build oxygen - enriched storage room in upper airway, and improve breathing efficiency.
  • There is low positive pressure at end-expiratory , promote alveolar open.
  • Good humidification, improve mucosa cleaning function, promote sputum discharge, reduce the chance of infection.
  • Good comfort and tolerance, high compliance for patients.


Clinical application value :

  • ICU emergency mild and moderate acute respiratory failure(hypoxic Non-CO2 retention ) -Improve breathing difficulty and the effect of improving oxygenation is obvious., The rate of intubation and mortality were significantly lower than that of noninvasive ventilation and standard oxygen therapy.
  • A new option from the creative withdrawal machine. - The drone fights and reduces the reintubation rate.
  • Acute heart failure or cardiogenic pulmonary edema. - Improve the symptoms of dyspnea and refractory hypoxia.
  • Hypoxic patients  assist  bronchoscopy, transesophageal ultrasonography and digestive endoscopy. - Added an effective oxygen therapy.
  • When the trachea is intubated(respiratory distress critical illness )  - Delay the time of hypoxemia.
  • Palliative treatment - New options for end-stage patients who reject intubation and resuscitation.


System composition :

  • HUMID-BM main machine
  • Heating tube
  • HUMID-BM humidification pot
  • Nasal cannula
  • Trolley
  • Oxygen flowmeter
  • Connecting pipe of Oxygen source
View Complete Details

HUMID-BH Respiratory Humidifier

  • Model HUMID-BH
  • Power Supply 220VAC+22V, 50+1Hz
  • Flow Setting Range Low Flow Mode 2-25L/Min temp 34oc, High Flow Mode - 10-80L/Min
  • Temperature Control 31oc, 34oc, 37oc
  • Oxygen/% Measure 21%-100%
  • Fio2 Control Auto Proportional Value Control
  • Alarm Parameters Low oxygen concentration alarm, High oxygen concentration alarm, Ambient temp alarm, Choke alarm
  • Recommended Ambient Temp 18oc-28oc
  • Standards IEC/EN 6060-1, IEC/EN 60601-1-2;1S08185
  • Package L330xW245xH315mm
  • Application Hospital

HiFent  nasal high flow, provide higher flow rate than conventional oxygen treatment by touch screen during high flow oxygen therapy and process, ideal solution for offering FiO2 that can be auto proportional valve controled, mixed gas with controlled temperature and humidity , so as to achieve better airway management and raise the level of oxygenation.

Applicable department : Comprehensive department and various ICU, pneumology Department, neurology, neurosurgery, chestsurgery, general surgery, paediatrics (weight >3kg), anesthesiologyrehabilitation department and so on.

Main features :

  • It provides mixed gas with high flow rate, high FiO2 and nearly 100% relative humidity, so as to achieve the following effects.
  • Keep a stable and high FiO2 , improve the effective ventilation of alveoli.
  • Reduce the dead space of nasopharynx, build oxygen - enriched storage room in upper airway, and improve breathing efficiency.
  • There is low positive end-expiratory pressure, promote alveolar open, increase end-expiratory lung volume.
  • Good humidification, improve mucosa cleaning function, promote sputum discharge, reduce the chance of infection.
  • Good comfort and tolerance, high compliance for patients.


Clinical application value :

  • ICU emergency mild and moderate acute respiratory failure(hypoxic Non-CO2 retention ) - Improve breathing difficulty and the effect of improving oxygenation is obvious, The rate of intubation and mortality were significantly lower than that of noninvasive ventilation and standard oxygen therapy.
  • A new option from the creative withdrawal machine - The drone fights and reduces the reintubation rate.
  • Acute heart failure or cardiogenic pulmonary edema - Improve oxygenation and reduce cardiac load.
  • Hypoxic patients  assist  bronchoscopy, transesophageal ultrasonography and digestive endoscopy - Added an effective oxygen therapy.
  • Chronic respiratory failure - Improve ciliary activity, promote sputum discharge, reduce the chance of infection.
  • Palliative treatment - New options for end-stage patients who reject intubation and resuscitation.
  • Cardiothoracic surgery is associated with a risk of respiratory failure - The results were comparable to non-invasive ventilation, but the patient was comfortable.


System features :

  • Great treatment
  • Super large output approximate saturated humidification
  • High accuracy of automatic oxygen control Special consumables with good characteristics
  • Humanized design
  • Beautiful screen compendious & clear
  • Extra Large Fonts Main parameters are displayed in the same box, as plain as daylight
  • Friendly interaction  Main parameters touch screen operation, friendly interface, meeting international habits
  • Characteristic consumables
  • Specialized Custom-made Imported humidification chamber, the best guarantee for humidification
  • Quiet and soft Softer and quieter nasal cannula;No irritation of nasal mucosa
  • A variety of interfaces Nasal cannula tracheostomy adapternasal cannula for pediatrics
  • Efficient disinfection
  • Simple and convenient 10 to 15 minutes, no need of manual care during disinfection
  • Good disinfection effect Ozone disinfection, cleanly and completely, no residue


System composition :

  • HUMID-BH main machine
  • Heating tube
  • HUMID-BH  humidification pot
  • Nasal cannula
  • Connecting pipe of Oxygen source
  • Trolley
View Complete Details

HUMID-BHR Respiratory Humidifier

  • Model HUMID-BHR
  • Power Supply 220VAC+22V, 50+1Hz
  • Flow Setting Range High Flow Mode - 10-60L/Min
  • Temperature Control 31oc, 34oc, 37oc
  • Oxygen/% Measure 21%-100%
  • Fio2 Control Manual Titration Control
  • Alarm Parameters Low oxygen concentration alarm, High oxygen concentration alarm, Ambient temp alarm, Choke alarm
  • Recommended Ambient Temp 18oc-28oc
  • Standards IEC/EN 6060-1, IEC/EN 60601-1-2;1SO8185
  • Package L330xW245xH315mm
  • Application Home Care

 Hifent™ high flow heated respiratory humidifiers for homecare, a new type of oxygen therapy device.The device can provide stable fraction of inspired oxygen in a certain range, give mixture gas of warmed and humidified air and oxygen to the needy, so as to achieve better airway management and improve oxygenation level.

Applicable Patients :

  • Family therapy stable phase COPD
  • Respiratory limitation due to the weak expectoration
  • Require high quality oxygen treatment
  • Mild to moderate OSAS