My ExportersIndia

For Buyer

For Seller

For Help

LE

Leistung
location Santa Catarina, Brazil

Write a Review

Surgical Equipments

Our offered Product range includes Mechanical Medical Ventilator PR4-g, Mechanical Medical Ventilator PR4D-02, Mechanical Medical Ventilator Luft2-g, Mechanical Medical Ventilator Luft 1-g and Medical Ventilator.

Mechanical Medical Ventilator PR4-g

  • Min. Order (MOQ) 1 piece
  • Patient type: Adult - Pediatric - Neonatal
  • To be used at: mobile units (ambulances) and emergency rooms, specific for emergency transport
Ventilation modesADULT / PEDIATRICAssist-controlled VCVAssist-controlled PCVPSV / CPAPSIMV (VCV) + PSVBack-up ventilation (VCV)Back-up ventilation (PCV)NEONATALContinuous flowNasal CPAPProgrammable alarmsMaximum pressureMinimum pressureMaximum tidal volumeMinimum tidal volumeApnea alarm timeMaximum frequencyNon-programmable alarmsI:E ratio inversionPEEPO2 supply failInterrupted cycleControls / Programmable parametersFIO2: 50-100%Rise time: 10-100 L/minInhalation time: 0.3 3 secFrequency: 1 150 cpmTidal volume: 10 1500 mlInspiratory pressure: 2 30 H2O cmSupport pressure: 2 30 H2O cmPEEP: 0 20 H2O cmPressure trigger sensitivity: -0.5 to -10.0 H2O cmAltitude compensation: 0 6000 msnmInspiratory pause0.10 - 2 segMonitoring / output parametersPeak airway pressure: 0 120 H20 cmMean airway pressure: 0 100 H2O cmInspiratory tidal volume: 50 1500 mlFrequency: 1 150 cpmI:E: 5:1 1:99Graphic monitorsPressure-time waveformWaveform holdAuto scaleOther features / functionsHistorics alarmsLung mechanics: Auto PEEP

Additional Information:

Payment Terms : T/T

View Complete Details

Mechanical Medical Ventilator PR4D-02

  • Min. Order (MOQ) 1 piece
  • To be used at: mobile units (ambulances) and emergency rooms, specific for emergency transport
  • Patient type: Adult - Pediatric
Adult and pediatric ventilation modesLimited cycling time by pressure/timeElectronic micro processedControlesInhalation timeExpiratory timeFrequencyI:E ratioFrequency: 5 to 60 cpmInhalation time: 0.6 to 2 secI:E ration: 1:1 to 1:5Inhalation pressure: from 0 to 100 H2O cm (with valve under adjustable pressure)Pressure gauge at airways: from -10 to 100 H2O cmFlowmeter: from 0 to 15 L/min with humidifier cupAlarmsInhalation maximum pressureInhalation minimum pressurePusher gas missingLow batteryPEEP (maximum and minimum)Micro processor (technical failure)Indication of external battery or sourcePower supplyExternal power source: 11 to 14.5 Vdc (2 A minimum)Battery autonomy: 720 min

Additional Information:

Payment Terms : T/T

View Complete Details

Mechanical Medical Ventilator Luft2-g

  • Min. Order (MOQ) 1 piece
  • Patient type: Adult - Pediatric - Neonatal
  • To be used at: Intensive Care Unit
Ventilation modesVCVPCVPSV/CPAPSINV (VCV) + PSVSMV (PCV) + PSVMMV + PSVPSV + assured tidal volumeBiphasic/bi-level APRVNIVMonitor17-inches LCD displayMonitoringAirways, peak, plateau, average and mean(PEEP) pressuresInspiration timeExpiration timeI:E ratioInspired/expired tidal air volumeInspiration peak flowDynamic complacencyTotal frequencySpontaneous or mechanic cycle graphic indicatorExpired minute volumeFIO2 concentrationAlarmsMaximum inspiration pressureMinimum inspiration pressureMaximum tidal expiration volumeMinimum tidal expiration volumeMaximum minute volumeMinimum minute volumeApneaMaximum respiration frequencyMaximum PEEPMinimum PEEPContinuous pressureAlimentation gas (air-O2) sourcePower failBattery chargeMicroprocessorInterrupted cycle

Additional Information:

Payment Terms : T/T

View Complete Details

Mechanical Medical Ventilator Luft 1-g

  • Min. Order (MOQ) 1 piece
  • Patient type: Adult - Pediatric
  • To be used at: Intensive Care Unit
Ventilation modesVCVPCVPSV/CPAPSIMV (VCV) + PSVMonitoring17-inches LCD displayMonitoringAirways, peak, plateau, average and mean (PEEP) pressuresInspiration timeExpiration timeI:E ratioInspired/expired tidal airway volumeInspiration peak flowDynamic complacencyTotal frequencySpontaneous or mechanic cycle graphic indicatorExpired minute volumeFIO2 concentrationAlarmsMaximum inspiration pressureMinimum inspiration pressureMaximum tidal expiration volumeMinimum tidal expiration volumeMaximum minute volumeMinimum minute volumeApneaMaximum respiration frequencyMaximum PEEPMinimum PEEPContinuous pressureInlet gas (air-O2) sourcePower failBattery chargeMicroprocessorInterrupted cycle

Additional Information:

Payment Terms : T/T

View Complete Details
Tell Us What are you looking for? Will call you back