We offer the best product range of Distilled Water Plant and Multi Column Distilled Water Plant.

Distilled Water Plant

  • CAPACITY 50 to 2500 Ltrs.
Purified water with max. conductivity of 0.5 micromhoscm. should be used.Pressure should be 1 kgcm higher than the in feed steam pressure.Temperature Ambient 30CSave water consumption & Boiler steam consumption.Complete close loop system. No air contamination.On line conductivity.If sub standard conductivity will come dumping automatically through 3 way valve
View Complete Details

Multi Column Distilled Water Plant

APPLICATION :

To generate WFI water for injection / Large volume of Parenteral.
CAPACITY :
  • 50 to 2500 Ltrs.

TECHNICAL SPECIFICATION :

Distillate -

  • IP/BP/USP specifications compliance.
  • Distillate Temperature 95C
  • Conductivity : Less than 0.5 Siemens/cm.
  • Endotoxing Less than 0.25 Eu./ml.
  • TOC 100 PPB

FEED WATER

  • Purified water with max. conductivity of 0.5 micromhos/cm. should be used.
  • Pressure should be 1 kg/cm higher than the in feed steam pressure.
  • Temperature Ambient 30C

COOLING WATER

  • Normal tap water is used
  • Provided hardness is less than 90 PPM of CaCo3.
  • Temperature Ambient 30C

STEAM

  • Steam must be saturated, dry free from oil, vapors and other impurities.(A steam filter to obtain 3, clear quality steam is recommended ask fordetails)
  • Pressure min steam pressure of 3 kg./cm is essential to guaranteepyrogen-free distillate.

OPERATION:

To feed purified water & heat with boiler steam & generate clean steam and condense with cool water which is WFI.

FEATURES :

  • Energy Saving - Low operating cost.
  • Compact Design - Space saving.
  • All contact parts are S. S 316L and all joints are sealed with Teflon Gasket.
  • Fully Automatic operation - No Attendant required.

ADVANTAGES :

  • Save water consumption & Boiler steam consumption.
  • Complete close loop system. No air contamination.
  • On line conductivity.
  • If sub standard conductivity will come dumping automatically through 3 way valve