| APPLICATION : To generate WFI water for injection / Large volume of Parenteral. |
| CAPACITY : |
| TECHNICAL SPECIFICATION : Distillate - - IP/BP/USP specifications compliance.
- Distillate Temperature 95C
- Conductivity : Less than 0.5 Siemens/cm.
- Endotoxing Less than 0.25 Eu./ml.
- TOC 100 PPB
FEED WATER - Purified water with max. conductivity of 0.5 micromhos/cm. should be used.
- Pressure should be 1 kg/cm higher than the in feed steam pressure.
- Temperature Ambient 30C
COOLING WATER - Normal tap water is used
- Provided hardness is less than 90 PPM of CaCo3.
- Temperature Ambient 30C
STEAM - Steam must be saturated, dry free from oil, vapors and other impurities.(A steam filter to obtain 3, clear quality steam is recommended ask fordetails)
- Pressure min steam pressure of 3 kg./cm is essential to guaranteepyrogen-free distillate.
|
| OPERATION: To feed purified water & heat with boiler steam & generate clean steam and condense with cool water which is WFI. |
| FEATURES : - Energy Saving - Low operating cost.
- Compact Design - Space saving.
- All contact parts are S. S 316L and all joints are sealed with Teflon Gasket.
- Fully Automatic operation - No Attendant required.
|
| ADVANTAGES : - Save water consumption & Boiler steam consumption.
- Complete close loop system. No air contamination.
- On line conductivity.
- If sub standard conductivity will come dumping automatically through 3 way valve
|