My ExportersIndia

For Buyer

For Seller

For Help

Our Products

  1. Heat Exchangers 4 Products available
  2. Cold Rooms 2 Products available
  3. Chillers 2 Products available
  4. Industrial Blowers, Coolers & Fans 2 Products available
  5. Air Compressor 1 Products available
  6. Curtains 1 Products available
  7. Cold Storage System 1 Products available
  8. Industrial Valves 1 Products available
  9. Industrial Air Cooler 1 Products available
  10. Chemical Reactors & Process Tanks 1 Products available
  11. Industrial Doors 1 Products available
  12. Window 1 Products available
  13. Machines And Equipments 1 Products available
  14. Domestic Fans, AC & Coolers 1 Products available
  15. Chemical Machinery & Plant 1 Products available
  16. Effluent Treatment Plant 1 Products available
  17. Refrigeration Parts 1 Products available
  18. Pumps, Pumping Machines & Parts 1 Products available
  19. Bushings & Bushing Parts 1 Products available
  20. Door Hinges 1 Products available
  21. Ripening Chamber 1 Products available
  22. Industrial Cooling Systems 1 Products available
  23. Breaker Panels 1 Products available
  24. Milk Processing Plant 1 Products available
  25. Plumbing Pipes 1 Products available
  26. Electric Control Panels 1 Products available
  27. Air Conditioning System 1 Products available
  28. Motor Control Panels 1 Products available

Electric Control Panels

Leading Manufacturer, Supplier & Retailer of Automatic Power Factor Panel.

Automatic Power Factor Panel

Power factor is the ratio between the KW and the KVA drawn by an electrical load where the KW is the actual load power and the KVA is the apparent load power. It is a measure of how effectively the current is being converted into useful work output and more particularly is a good indicator of the effect of the load current on the efficiency of the supply system.

 

All current flow causes losses both in the supply and distribution system. A load with a power factor of 1.0 results in the most efficient loading of the supply. A load with a power factor of, say, 0.8, results in much higher losses in the supply system and a higher bill for the consumer. A comparatively small improvement in power factor can bring about a significant reduction in losses since losses are proportional to the square of the current.When the power factor is less than one the ‘missing’ power is known as reactive power which unfortunately is necessary to provide a magnetizing field required by motors and other inductive loads to perform their desired functions. Reactive power can also be interpreted as wattles, magnetizing or wasted power and it represents an extra burden on the electricity supply system and on the consumer’s bill.

 

Specifications :

  • A poor power factor is usually the result of a significant phase difference between the voltage and current at the load terminals, or it can be due to a high harmonic content or a distorted current waveform.
  • A poor power factor is generally the result of an inductive load such as an induction motor, a power transformer, and ballast in a luminary, a welding set or an induction furnace. A distorted current waveform can be the result of a rectifier, an inverter, a variable speed drive, a switched mode power supply, discharge lighting or other electronic loads.
  • A poor power factor due to inductive loads can be improved by the addition of power factor correction  equipment, but a poor power factor due to a distorted current waveform requires a change in equipment    Design or the addition of harmonic filters.
  • Some inverters are quoted as having a power factor of better than 0.95 when, in reality, the true power factor is between 0.5 and 0.75. The figure of 0.95 is based on the cosine of the angle between the voltage and current but does not take into account that the current waveform is discontinuous and therefore contributes to increased losses.
  • An inductive load requires a magnetic field to operate and in creating such a magnetic field causes the current to be out of phase with the voltage (the current lags the voltage). Power factor correction is the process of compensating for the lagging current by creating a leading current by connecting capacitors to the supply.
  • P.F (Cos Ǿ)= K.W / KVA  Or
  • P.F (Cos Ǿ)=  True Power / Apparent Power.
  • KW is Working Power (also called Actual Power or Active Power or Real Power).
  • It is the power that actually powers the equipment and performs useful work.
  • KVAR is Reactive Power.
  • It is the power that magnetic equipment (transformer, motor and relay)needs to produce the magnetizing flux.
  • KVA is Apparent Power.
  • It is the “vectorial summation” of KVAR and KW.