Our Products
With long years of experience in the industry, we are able to manufacture and supply excellent range of Infant Phototherapy Units. These infant phototherapy units are highly reliable and excellent equipment used for treatment of babys jaundice. Our infant phototherapy units are very robust, smooth and fitted with high quality lights for effective phototherapy. These infant phototherapy units have adjustable height and wheeled base for efficient use. Clients can avail from us our range of infant phototherapy units are available at affordable prices.
Features:
Premium grade
Sturdy
Rust proof
Economical
Product Description
This is another budget roller which is ideally suited to anyone looking for a low cost roller which can still hold its own with the other brands. It is popular with those people looking to use a derma roller for skin problems such as stretch marks and scars. It is suitable for use on all types of skin and is considered a very effective roller.
Healthcare sector is booming across the world and products & services are increasingly playing a dominant role in driving and shaping the life of the people both in terms of corrective and preventive ways. C Cube Advanced Technologies is committed to serve the healthcare needs with innovative products and services to help doctors/practitioners stay in the frontline.In the ever-changing competitive world C Cube Advanced Technologies is providing ways for organizations to be successful by outsourcing very important business process of Wire Harness & assembling. C Cube Advanced Technologies is all set to deliver wire harness and assembly solutions in a cost effective and elegant manner.
Product Description
Function:
1.Anti-Puffiness,
2. Stretch Mark Removal and Stretch Mark Treatment
3.Acne Scar Removal, Acne Scar Treatment
4 Anti Wrinkle Treatment, Anti Aging
5. Hair Loss Treatment or Hair Restoration
6. Surgical Scar Removal.
Needle function:
1. automatic high speed roll(max speed 10003000 turn per minute), producing Twelve delivery channels.
2. various micro-needle mode to stimulate skin:
a. strengthen skin to absorb beauty production, the absorbency of skin can be reach above 40 times, and improve acne scar more than 50%.
b.the skin will be luster and elasticity, differ from laser or chemical substances, it is non invasive, can improve skin and enhances absorption.
3. the micro-needle of depth can be adjusted(0.25mm-2.0mm), greatly improved the treatment
Micro-needling is the use of multiple needles that vertically pierce the skin to allow for greater absorption of topically applied skin care products, enhanced stimulation of collagen and elastin growth, and visible improvements in skin tone.Micro-needling opens temporary channels in the most superficial layer of the skin and promotes natural healing process of producing new skin cells to replace aged or damaged skin.
Derma pen
Minimised epidermal damage
Less pain and erythema as high speed with vertical direction
More easy to operate at the small or curved areas
Adjust micro needle length (0.252.0mm)
Prevent cross infection, adopt with disposable needles
More quickly and efficient than manual Micro-needle
Derma rollers:
More painful with a lot more bleeding due to epidermal damage
Difficult to use in small or curved areas
Difficult to insert needle into scar tissue needles can be bent
No needle height adjust me
Specification:
Voltage: 5V
Input: AC100-220V, 50-60Hz
Micro needles length: able length of micro-needle (0.25mm, 0.5mm, 1.0mm.1.5mm. 2.0mm)
Speed: Stage 19 adjustable.
Total needle number: 12 needles
Needle material : Titanium needle
Automatic high speed roll(max speed 10003000 turn per minute)
How to use it?
Before use checking points:
1. Whether the needle cartridge is in sterilized package.
2. Operate it on the health skin
3. Clean the hands of operator, and the operation area on skin should be cleaned.
4. Disposable needles cannot be used repeatedly.
Operation
Follow 3 steps of needling to enhance forming channels
Horizontally-vertically-diagonal
Each step has to be repeated 3 times at once.
Treatment: 6 treatment for one period, One treatment at the interval
Attention:
1. For the safety, use one roller per one person only.
2. Do not force the roller into the skin but simply use mild pressure.
3. Roller obliquely at the same intensity covering the same areas vertically and horizontally.
4. After the treatment, apply post-care solutions for the skin protection. Dont apply water in the treated skin within 8-12 hours.
Include:
1 x Power supply
1x machine
10 pcs needle cartridge
1x Instruction book
Special Features
Radio surgery cutting current can be more versatile than a laser for smoothing and finishing skin wounds or revising scars after skin cancer surgery. Radio frequency current technology that will help Physicians/ Surgeons to fine tune the repair of surgical defects is a new application that will help surgeons make the best use of their investments in the instrument.
Patient satisfaction with this technique is very high because radio surgery causes less bleeding than conventional surgery, allowing the post operative skin defects to be more easily camouflaged.
Other advantages: Faster wound healing and ability to remove the sutures in 24 hours compared to scalpel incision that is on the fifth or sixth post operative day.
High Current: Higher intensities can be used for complete excision of skin lesions and debulking of scars.
Low Current: Radio frequency at a medium energy level produces uniform, shallow vaporization of tissue as the instrument is run tangentially across the skin. Use of the cutting current, instrument for fine corrections is enhanced by use of a surgical loupe with 2X to 4X magnification or a least with simple head loupe plain, assuring good visualization and smoothing of small surface irregularities with pin point accuracy.
DIFFERENT TYPES OF WIRE ELECTRODE AND USAGES:
Wire electrodes and loop electrodes available for different applications. Mostly wire electrodes are used for cutting & coagulation work, even bigger area to be sliced off. Otherwise wire loop electrode is used depending upon the size and area located. Power output should be set slowly from the lower level as per the surgeons need. However the required output can be selected by surgeons after doing a number of cases.
Electrode Surface Area: The larger the electrode, the greater the heat & the need to increase the power supply. Thinner the needle, the less heat will be produced & less power supply. Thinner the needle, the less heat will be produced & less power supply.
Wave form: Cutting wave form- least heat.
Haemo: Some lateral heat coagulation, more lateral heat frequency.
Frequency: Higher the frequency, less lateral heat produced.
Temperature Achievement:
A small electrode (0.5mm thick) is used for lower power setting and less lateral heat is produced. A thinner and finer electrode is mostly used in many places, which is better than using a thicker electrode resulting in need of higher power setting and no significant difference in tissue destruction. A variety of electrodes are available but the standard set of 7 electrodes can be used effectively. Needle electrodes for incisions: Loop electrodes excise small skin lesions or to shave superficial lesions. A diamond shape electrode is used for elliptical excisions. A very fine thinner needle (0.3mm thick) is for epilation work.
VARIOUS APPLICATIONS
Plastic Surgery: Face lift, Breast Reconstruction, excision of skin lesions. Blepharoplasty.
Treating Facial Telangiectasias:
Removal of telangiectasias by conventional methods like Electro- cautery etc.: Patients experience discomfort and intolerable pain-efforts and surgery must be discontinued. In addition, some patients will develop small dells or depressions associated with dessication, crust formation and healing.
Dermatology-Warts: Warts are common cutaneous and many different means have been used in treatment of them. A Loop electrode diameter (6.35mm) is inserted around the wart and pushed down the center rather than straight across. Care must be taken not to penetrate into the dermis because this may lead to scar formation. Little scarring , if any, will result in the affected epidermis alone being removed and the dermis left intact. For very smaller warts and flat warts, loop (1-2mm in diameter) electrode is not advisable, and pointed electrode is commonly used. Loop electrode is suitable for periungual and subungual warts, condyloma accuminata and plantar warts.
The frequency radio surgical instrument has proven to be a boon for dermatological and plastic surgery, as it allows many more procedures to be accomplished in an office setting. In addition, patient acceptance has been high, because of more rapid healing time and superior cosmetic results as with cold knife. For example, facial telangiectasias by radio frequency minimized discomfort and completely eliminated dells or depression and severe pain or bleeding. With it, one can treat the patients face and neck area in one sitting and it can also be operated in very low current setting compared to other methods with higher frequency.
Eyelid Surgery: Excellent results have been obtained removing seborrheic keratosis from the upper eyelid and there are many papers describing Blepharoplasty and similar papers.
E.N.T: Radio assisted Uvulopalatoplasty, removal of vascular lesion within the mouth, Epistaxis Hemangiomas and tongue lesion removal.
General Surgery: Simple incision/biopsy is very easy to perform as described earlier. Varicose veins, including thread veins, have been successfully treated.
Podiatry: The excision of plantar fibromata verrucae and ingrown toe nails have all been widely documented with good results. Many surgeons now use nail matrix phenolization for the management of ingrown toe nails. Instead of applying a phenol swab, an insulated nail electrode can be used and the germinal epithelium destroyed using the coagulation current. This gives faster immediate post operative healing and recurrence rate approx. 5%, and 95% cure rates reported.
Vasectomy: Several papers have described successful techniques for this operation using the cutting waveform to incise the scrotal skin and the coagulation waveform to destroy and seal the vas.
Learning Radio Surgery: With a piece of steak, the doctor can practice most radio surgery techniques, including cutting, biopsy & coagulation.
Standard Accessories:
Monopolar Handle- 1 no, Patient Plate- 1 no, Electrodes Set- 1 no, Foot Switch- 1 no
Hand Switch- 1 no, Bipolar / forceps- 1 no, Cleaning Knife- 1 no.
Product Description
Function:
1.Anti-Puffiness,
2. Stretch Mark Removal and Stretch Mark Treatment
3.Acne Scar Removal, Acne Scar Treatment
4 Anti Wrinkle Treatment, Anti Aging
5. Hair Loss Treatment or Hair Restoration
6. Surgical Scar Removal.
We provide Sturdy and reliable Single and Twin Oxygen Flow Meters for accurate measurement of flow of gases. Our Medical Oxygen Flow Meter is available with Chromium plated Brass Body that assures high durability. We have carved a niche as one of the supreme Oxygen Flow Meter Suppliers based in India.
Salient Features
Metering tube and cover made of Unbreakable Poly carbonate
Flow adjustment by Needle Valve equipped with inlet filter- 100um
Flow rate range 0- 15 liters per minute
Flush Flow 60 liters per minute
Read the flow on the center of the ball
Inlet pressure 60 psi
Bubble Humidifiers
Humidifier jar may be steam autoclaved/gas sterilized
Materials of Construction
Lid : ABS Plastic
Jar : Unbreakable Poly Carbonate
Pressure valve : Brass Chromium plated
Features:
Water Repellent Fabric
Durable
Eye-catching Look
High Tensile Strength
Wrinkle Free
Fade-resistant
Available In Multiple Colour Structures
Rust Proof Tracks And Hooks
Salient features
1. The Controller is based on Micro Computerized system.
2. Large bright display are easy to monitor and for viewing from a distance.
3. Digital display system provided to measure the Infant temperature, Air temperature and to set the required temperature.
4. Feature touch keys provided for easy operation.
5. Bar graph LED system provided to indicate the heater output.
6. Fault indications with alarm for:
Baby probe failure
Air probe failure
10 C temperature high, 10 C temperature low
High temperature cut-off
Power failure
7. Built-in IV pole
8. Low T-shaped base slides conveniently under other equipment.
9. Dimension: 185 x 100 x 65 cm
10. Heater:
Material: Ceramic
Power: 1000 watt
220- 240 V
Contains parabolic aluminum reflector behind the heater
11. Temperature controller:
Both manual and automatic modes
Air probe (Air temp control)
2 Display controller
12. Main power supply:
230 V + 10
Power cord: 3m, 6A
Two 6 A fuses
13. Baby Tray:
Dimension: 43 x 63
Base plate & side walls are made of Acrylic material of 6mm thickness.
Tray is tiltable at 80
Side walls can be collapsed using knobs
14. Body of the entire unit:
Made of Mild steel.
Colour: combination of 7035 (white) and DA gray (gray)
Protection: safety earthing at 2 places.
Four 4 inch wheels to move the unit
15. Other facilities:
Monitor tray (25 x 24 cm)
Utility stand
IV stand
Handle to move the unit
16. Heater to baby distance is 90 cm.
Salient features
1. The Controller is based on Micro Computerized system.
2. Large bright display are easy to monitor and for viewing from a distance.
3. Digital display system provided to measure the Infant temperature, Air temperature and to set the required temperature.
4. Feature touch keys provided for easy operation.
5. Bar graph LED system provided to indicate the heater output.
6. Fault indications with alarm for:
Baby probe failure
Air probe failure
10 C temperature high, 10 C temperature low
High temperature cut-off
Power failure
Our organization is engaged in manufacturing and supplying premium array of Infant Bassinets. These infant bassinets are widely used in different hospitals, clinics and laying-in centers for receiving newborn babies. Our infant bassinets are very durable, flawlessly crafted and user friendly with stainless steel structure fitted with glass enclosure and comfortable bedding. These infant bassinets have wheeled base and below tray for organizing other materials needed. We are offering our infant bassinets at market leading prices.
Features:
Best quality
Supreme strength
Flawlessly crafted
Cost efficient
Mesotherapy is a minimally invasive procedure that is widely used in Europe and elsewhere to treat various injuries and medical conditions. This medical specialty targets problem areas with microinjections of conventional or homeopathic medicines, vitamins, minerals and amino acids. Tiny "medicinal bullets" are delivered directly into the mesoderm (middle layer of skin) that are highly specific to the condition being treated. Among its many applications, Mesotherapy can be used for the following:
Mesotherapy to eliminate cellulite
Mesotherapy to promote weight loss
Mesotherapy to provide anti-aging benefits
Mesotherapy to eliminate localized fat deposits
Work Theory
It uses Electroporation and Electroosmosis techniques, (needle-free mesotherapy or mesoderm or cell rupture) technique, without any injectors, easily opens the aquaporin(AQP), transports skin wanted nutrition, so as to treat all kinds of skin problems. With the application of Electrophoresis energy to the beauty industry, It takes "point to point "infiltration techniques, by orientation, l ayer-oriented and ration to transport high-energy nutrition serum directly into the skin tissue, let it quickly being absorbed and effective, promote skin metabolism, keep skin elastic and fine.
Benefits
Increases blood supply to the scalp by 54% after only one treatment
Stops the progression of Hair Loss
Get Maximum Coverage
Stimulates regrowth
Repairs and improves hair shaft quality
Enhances lasting effects of hair colour and perms by closing the cuticle creates the healthiest environment where hair can grow
Hair looks shinier and split ends show remarkable improvement after only a few treatments.
Thickens existing hair and strengthens it.
Vellus hair, and very often dormant roots, can be restimulated into healthy growing hair
Technical Specifications:
Operating Condition: 230V, 50Hz
Dimensions in cms: 29(L)X23(W)X20(H)
Optical Characteristics: 650nm, 5mW
No. of LEDs: 28 Nos. with special laser router
Timer: Adjustable auto therapy for 20 minutes
Colours available: Silky Silver, Pearl White
Packages contains:
1. Laser Dome
2. Timer with Battery
3. Charger
4. User Manual
6. Carry Bag
Function:
1.Anti-Puffiness,
2. Stretch Mark Removal and Stretch Mark Treatment
3.Acne Scar Removal, Acne Scar Treatment
4 Anti Wrinkle Treatment, Anti Aging
5. Hair Loss Treatment or Hair Restoration
6. Surgical Scar Removal.
Needle function:
1. automatic high speed roll(max speed 10003000 turn per minute), producing Twelve delivery channe
2. various micro-needle mode to stimulate skin:
a. strengthen skin to absorb beauty production, the absorbency of skin can be reach above 40 times, and improve acne scar more than 50%.
b.the skin will be luster and elasticity, differ from laser or chemical substances, it is non invasive, can improve skin and enhances absorption.
3. the micro-needle of depth can be adjusted(0.25mm-2.0mm), greatly improved the treatmen
Micro-needling is the use of multiple needles that vertically pierce the skin to allow for greater absorption of topically applied skin care products, enhanced stimulation of collagen and elastin growth, and visible improvements in skin tone.Micro-needling opens temporary channels in the most superficial layer of the skin and promotes natural healing process of producing new skin cells to replace aged or damaged skin.
Derma pen
Minimised epidermal damage
Less pain and erythema as high speed with vertical direction
More easy to operate at the small or curved areas
Adjust micro needle length (0.252.0mm)
Prevent cross infection, adopt with disposable needles
More quickly and efficient than manual Micro-needle
Derma rollers:
More painful with a lot more bleeding due to epidermal damage
Difficult to use in small or curved areas
Difficult to insert needle into scar tissue, needles can be bent
No needle height adjustment.
Specification:
Voltage: 5V
Input: AC100-220V, 50-60Hz
Micro needles length: able length of micro-needle (0.25mm, 0.5mm, 1.0mm.1.5mm. 2.0mm)
Speed: Stage 19 adjustable.
Total needle number: 9, 12, 36 and nano needles
Needle material : Titanium needle
Automatic high speed roll(max speed 10003000 turn per minute)
How to use it?
Before use checking points:
1. Whether the needle cartridge is in sterilized package.
2. Operate it on the health skin
3. Clean the hands of operator, and the operation area on skin should be cleaned.
4. Disposable needles cannot be used repeatedly.
Operation
Follow 3 steps of needling to enhance forming channels
Horizontally-vertically-diagonal
Each step has to be repeated 3 times at once.
Treatment: 6 treatment for one period, One treatment at the interval
Attention:
1. For the safety, use one roller per one person only.
2. Do not force the roller into the skin but simply use mild pressure.
3. Roller obliquely at the same intensity covering the same areas vertically and horizontally.
4. After the treatment, apply post-care solutions for the skin protection. Donot apply water in the treated skin within 8-12 hours.
Include:
1 x Power supply
1x machine
10 pcs needle cartridge
1x Instruction book
Woods Lamp Portable Model comes with twin UV tubes to induce fluorescence in Dermatoses and an additional extra white tube for magnification. Both the lights can be operated separately. Examination of skin or hair with the Woods Lamp is a time trusted technique to aid in the clinical diagnosis of some cutaneous disorders.
Following are the indications in Dermatology:
Dermatoses in the intertrignious areas
Patches on the scalp with scaling or partial hair loss (especially with broken hairs)
Pigmentary alterations
Diagnosis of burrows in scabies
Blisters and punctuate erosions on the dorsum of hands and forearms
Tinea versicolor
Woods Lamp is inexpensive and essential laboratory equipment. Woods light examination
should be performed in a dark room, and total darkness is also satisfactory
The UV light tubes are commercially available and the emitted light is of lesser intensity
(longer wave length) than the light absorbed