Post Buy Requirement
CE
Mumbai, Maharashtra, India
Add Review

Industrial Valves #225591

Diaphragm Pressure Reducing Valves

Diaphragm Pressure Reducing valves are also sometimes known as pressure regulators, as they are used to protect against the effects of high level water pressures. Basically Municipal and private water supply companies use pumps and pumping stations to boost water supply pressure in supply mains, so that they should be able to supply water for fire fighting, high rise building to overcome loss of pressure as the altitude increases, and to maintain water supply in water towers and supply tanks. Pressure in water supply mains can exceed 200 psi.

View Complete Details

Vacuum Valves



















introduction

vacuum & safety valves is suitable for all kinds of water heaters and the container and steam system.


using method

vacuum & safety valves is suitable for all kinds of water heaters and the container and steam system. When water heater and steam system present the vacuum state, can open the system that originally closed automatically, make it dispel the vacuum state that may appear while entering air. Prevent from because siphon water in being function systematic take out and cause container collapse or water heater wait for device to be braised to burn.



technical parameter

vacuum:


View Complete Details

Thermostatic Mixing Valves










MAIN CHARACTERISTICS AND USES
The RA thermostatic mixings valves are used in hot water systems for sanitary use. They keep the temperature of mixed water supplied to the user constant even when the condition listed below vary:

  • Temperature

  • Supply pressure

  • Incoming hot and cold water flow


The RA thermostatic mixing valves have a temperature range that is ideal for heating a centralized water system with heater . They also have an internal anti-limestone lining.

OPERATION :The valves were designed to supply domestics hot water at an adjustable and constant temperature where no other regulating system is present. The very sensitive thermostatic elements is positioned centrally inside the out going stream union and its guides a regulating shutter which adjusted the ingoing cold water flow to the hot water flow according to the required water temperature . The knob can be used to regulate the temperature of the outgoing water.

MATERIALS :

  • Shutter - Brass

  • Body - Brass

  • Tap - Brass

  • Spring - Stainless steel

  • Knob - PA6


DIMENSIONS AND HYDRAULIC CHARACTERISTICS
Model G L A C KVS(m³/h)
          C-MIX H-MIX
15 G1/2 146 82 148 1.6 1.7
20 G3/4 146 82 148 1.6 1.7
25 G1 74 46 112 1.6 1.7
32 G1/4 74 46 112 1.6 1.7
View Complete Details

Automatic Air Vent Valve

  • Maximum allowable pressure (PN)  
  • 10 bar Minimum sealing pressure
  •   0.2 bar (Grade A according to EN 12266-1)
  • Range of operation air evacuation  
  • from 0.5 bar to 5 bar (tolerance ± 10% max. detected) Temperature :
  •    
  • Maximum allowable working temperature (TS)  
  • 180° C (200° C in brief periods) Compatible fluids :
  • Glycolate solutions (glycol)  
  • water and fluids Group 2 Heat transfer fluids in compliance with Italian national standards (UNI 8065 § 6)
  •   Generic Fluids
  •   50%
  • Threading:  
  •   Pipeline connection
  •   Threads according to ISO 228/1
  • Requirements and tests as per :  
  •   EN 1074-4
  • Body and Plug in brass  
  • EN 12165 - CW617N Seat and internal mechanisms
  •   Brass - EN 12164 - CW614N
  • Gaskets and o-ring  
  • FLUORINATED RUBBER (VITON - FPM) Spring and counterweight
  •   STAINLESS STEEL EN 10088-14310 (AISI 302)

This automatic air vent valve is a single float valve designed for solar thermal energy plants, and carries out two main functions: the evacuation of a consistent air flow through the system (e.g. during loading/pressurization of the plant), and degassing which discharges air trapped in the pipeline, while functioning, in particular in the solar collectors. This valve has a paramount importance in solar thermal energy plants, evacuating and discharging trapped air in the pipelines and in the solar collectors. As a matter of fact, the presence of oxygen in the system can provoke numerous negative phenomena such as anodic corrosion, localized noise, air pockets, obstructions, etc., which may significantly compromise the performance and integrity of the systems. These valves are usually installed at the summit of the primary circuit in a solar thermal energy plant, and are resistant to the high temperatures that the heat-transfer fluids can reach, even in stagnation phases. Their suitability for application in solar thermal energy plants conforms to EN 12976 and EN 12977.

View Complete Details

RBM Air Vent













AUTOMATIC AIR VENT / AIR RELEASE VALVE
Automatic air vent valve prupose of installation in hot & cold water system to eliminate entrapped air in water lines. Prevent air locking due to filling of system or while priming of pump systems to increase thermal efficiency. To increase thermal efficiency fitted with check valve to prevent air being drawn back into system or water escaping from port event.






















INSTALLATION: VERTICALLY

  • Valve body nickle plated in forged brass

  • Working temperatures 90C

  • Working pressure range 6 bar - test pressure 16 bar

  • EPDM valve head

  • Float: plastic float (PP resin)

  • Lever: ASTM C36600

  • Spring: AISI 302


PRODUCT SIZE
12 - M - 3/8"
15 - M - 1/2"
20 - M - 3/4"
25 - M - 1"

View Complete Details

Diaphragm Pressure Reducing Valves With Stainless Steel Seat






















HYDRAULIC FEATURES

Models suitable to reduce pressure (max 16 bar).


TECHNICAL FEATURES
Max inlet working pressure: 16 bar
Setting: min. 1, 5 max 7 bar
Variation % of the setting changing the inlet pressure: 5% Max temperature (water): 80C
Pre-setting: 3 bar
Threading for Waterworks: UNI ISO 228/1.
Manometer joint: ISO 7/1
CONSTRUCTION
Sizes " - 1" in brass UNI EN 12165 - CW617N
Sizes 1" - 2" in brass UNI EN 1982 - CB753S
NBR diaphragm with textile inserts
Seat washers and washers in NBR rubber
Stainless steel seat AISI 303
View Complete Details

Metal Seat Check Valve

Suitable for industrial, pneumatic and hydraulic installations. Ideal for hot / cold water, different oils and compressed air. It can be fitted in horizontal, vertical or oblique position.



















TECHNICAL FEATURES
Minimum and Maximum working temperature:
Air: -20 C, 110 C
Water: 0 C, 90 C
Gas: -20 C, 60 C
Available: In all sizes from " up to 4".
Thread: ISO228 - DIN259 - Bs2779.
Available: In the sizes of 2"-3" and 4" with American thread NPT.
MATERIALS
Valve Body:Brass CW 617 N.
Internal Seat:Stainless steel plate AISI 304 fitted with NBR 60 SH/A, cover plate and rod in brass CW 614N.
Spring:Stainless steel - AISI 302.
View Complete Details

Nylon Seat Check Valve

  • Air -20° C, 110° C
  • Water 0° C, 90° C
  • Gas: -20° C, 60° C
  • Thread: ISO228 - DIN259 - Bs2779.















TECHNICAL FEATURES
Minimum and Maximum working temperature:
Water: 0 C, 90 C
Gas: -20 C, 60 C
Available: In all sizes from " up to 4"
Thread: ISO228 - DIN259 - Bs2779.
MATERIALS
Valve Body:Brass CW 617 N.
Stem Seat:Nylon 6.
Seat:NBR 60 SH/A.
Spring:Stainless steel - AISI 302.
View Complete Details

Mixing Valve

The Thermostatic mixing valve (TMV) is installed in sanitary systems, in order to obtain energy savings, comfort when using hot water, avoiding the risks of burns caused by extremely high working temperatures. It can be installed in a boiler room on the main hot water sanitary columns, next to wall boilers or water accumulation boilers, or in the distribution cabinets in case of manifold pliable sanitary systems.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Chintan Sheth (Chintan Enterprise)
  • 54,UNIVERSAL INDUSTRAIL ESTATE,IB PATEL ROAD,GOREGAON-EAST, MUMBAI, Maharashtra - 400003
  • Share us via
Retailer of Industrial Valves from Mumbai, Maharashtra by Chintan Enterprise
Post Buy Requirement
CE
Mumbai, Maharashtra, India
Add Review

Industrial Valves #225591

Diaphragm Pressure Reducing Valves

Diaphragm Pressure Reducing valves are also sometimes known as pressure regulators, as they are used to protect against the effects of high level water pressures. Basically Municipal and private water supply companies use pumps and pumping stations to boost water supply pressure in supply mains, so that they should be able to supply water for fire fighting, high rise building to overcome loss of pressure as the altitude increases, and to maintain water supply in water towers and supply tanks. Pressure in water supply mains can exceed 200 psi.

View Complete Details

Vacuum Valves

introduction

vacuum & safety valves is suitable for all kinds of water heaters and the container and steam system.

using method

vacuum & safety valves is suitable for all kinds of water heaters and the container and steam system. When water heater and steam system present the vacuum state, can open the system that originally closed automatically, make it dispel the vacuum state that may appear while entering air. Prevent from because siphon water in being function systematic take out and cause container collapse or water heater wait for device to be braised to burn.

technical parameter
vacuum:

View Complete Details

Thermostatic Mixing Valves

MAIN CHARACTERISTICS AND USES
The RA thermostatic mixings valves are used in hot water systems for sanitary use. They keep the temperature of mixed water supplied to the user constant even when the condition listed below vary:
  • Temperature
  • Supply pressure
  • Incoming hot and cold water flow
The RA thermostatic mixing valves have a temperature range that is ideal for heating a centralized water system with heater . They also have an internal anti-limestone lining.

OPERATION :The valves were designed to supply domestics hot water at an adjustable and constant temperature where no other regulating system is present. The very sensitive thermostatic elements is positioned centrally inside the out going stream union and its guides a regulating shutter which adjusted the ingoing cold water flow to the hot water flow according to the required water temperature . The knob can be used to regulate the temperature of the outgoing water.

MATERIALS :
  • Shutter - Brass
  • Body - Brass
  • Tap - Brass
  • Spring - Stainless steel
  • Knob - PA6

DIMENSIONS AND HYDRAULIC CHARACTERISTICS
Model G L A C KVS(m³/h)
          C-MIX H-MIX
15 G1/2 146 82 148 1.6 1.7
20 G3/4 146 82 148 1.6 1.7
25 G1 74 46 112 1.6 1.7
32 G1/4 74 46 112 1.6 1.7
View Complete Details

Automatic Air Vent Valve

  • Maximum allowable pressure (PN)  
  • 10 bar Minimum sealing pressure
  •   0.2 bar (Grade A according to EN 12266-1)
  • Range of operation air evacuation  
  • from 0.5 bar to 5 bar (tolerance ± 10% max. detected) Temperature :
  •    
  • Maximum allowable working temperature (TS)  
  • 180° C (200° C in brief periods) Compatible fluids :
  • Glycolate solutions (glycol)  
  • water and fluids Group 2 Heat transfer fluids in compliance with Italian national standards (UNI 8065 § 6)
  •   Generic Fluids
  •   50%
  • Threading:  
  •   Pipeline connection
  •   Threads according to ISO 228/1
  • Requirements and tests as per :  
  •   EN 1074-4
  • Body and Plug in brass  
  • EN 12165 - CW617N Seat and internal mechanisms
  •   Brass - EN 12164 - CW614N
  • Gaskets and o-ring  
  • FLUORINATED RUBBER (VITON - FPM) Spring and counterweight
  •   STAINLESS STEEL EN 10088-14310 (AISI 302)

This automatic air vent valve is a single float valve designed for solar thermal energy plants, and carries out two main functions: the evacuation of a consistent air flow through the system (e.g. during loading/pressurization of the plant), and degassing which discharges air trapped in the pipeline, while functioning, in particular in the solar collectors. This valve has a paramount importance in solar thermal energy plants, evacuating and discharging trapped air in the pipelines and in the solar collectors. As a matter of fact, the presence of oxygen in the system can provoke numerous negative phenomena such as anodic corrosion, localized noise, air pockets, obstructions, etc., which may significantly compromise the performance and integrity of the systems. These valves are usually installed at the summit of the primary circuit in a solar thermal energy plant, and are resistant to the high temperatures that the heat-transfer fluids can reach, even in stagnation phases. Their suitability for application in solar thermal energy plants conforms to EN 12976 and EN 12977.

View Complete Details

RBM Air Vent

AUTOMATIC AIR VENT / AIR RELEASE VALVE
Automatic air vent valve prupose of installation in hot & cold water system to eliminate entrapped air in water lines. Prevent air locking due to filling of system or while priming of pump systems to increase thermal efficiency. To increase thermal efficiency fitted with check valve to prevent air being drawn back into system or water escaping from port event.
INSTALLATION: VERTICALLY
  • Valve body nickle plated in forged brass
  • Working temperatures 90C
  • Working pressure range 6 bar - test pressure 16 bar
  • EPDM valve head
  • Float: plastic float (PP resin)
  • Lever: ASTM C36600
  • Spring: AISI 302
PRODUCT SIZE
12 - M - 3/8"
15 - M - 1/2"
20 - M - 3/4"
25 - M - 1"
View Complete Details

Diaphragm Pressure Reducing Valves With Stainless Steel Seat

HYDRAULIC FEATURES

Models suitable to reduce pressure (max 16 bar).

TECHNICAL FEATURES
Max inlet working pressure: 16 barSetting: min. 1, 5 max 7 barVariation % of the setting changing the inlet pressure: 5% Max temperature (water): 80CPre-setting: 3 barThreading for Waterworks: UNI ISO 228/1.Manometer joint: ISO 7/1
CONSTRUCTION
Sizes " - 1" in brass UNI EN 12165 - CW617NSizes 1" - 2" in brass UNI EN 1982 - CB753SNBR diaphragm with textile insertsSeat washers and washers in NBR rubberStainless steel seat AISI 303
View Complete Details

Metal Seat Check Valve

Suitable for industrial, pneumatic and hydraulic installations. Ideal for hot / cold water, different oils and compressed air. It can be fitted in horizontal, vertical or oblique position.

TECHNICAL FEATURES
Minimum and Maximum working temperature:Air: -20 C, 110 CWater: 0 C, 90 CGas: -20 C, 60 CAvailable: In all sizes from " up to 4".Thread: ISO228 - DIN259 - Bs2779.Available: In the sizes of 2"-3" and 4" with American thread NPT.
MATERIALS
Valve Body:Brass CW 617 N.
Internal Seat:Stainless steel plate AISI 304 fitted with NBR 60 SH/A, cover plate and rod in brass CW 614N.
Spring:Stainless steel - AISI 302.
View Complete Details

Nylon Seat Check Valve

  • Air -20° C, 110° C
  • Water 0° C, 90° C
  • Gas: -20° C, 60° C
  • Thread: ISO228 - DIN259 - Bs2779.
TECHNICAL FEATURES
Minimum and Maximum working temperature:Water: 0 C, 90 CGas: -20 C, 60 CAvailable: In all sizes from " up to 4"Thread: ISO228 - DIN259 - Bs2779.
MATERIALS
Valve Body:Brass CW 617 N.
Stem Seat:Nylon 6.
Seat:NBR 60 SH/A.
Spring:Stainless steel - AISI 302.
View Complete Details

Mixing Valve

The Thermostatic mixing valve (TMV) is installed in sanitary systems, in order to obtain energy savings, comfort when using hot water, avoiding the risks of burns caused by extremely high working temperatures. It can be installed in a boiler room on the main hot water sanitary columns, next to wall boilers or water accumulation boilers, or in the distribution cabinets in case of manifold pliable sanitary systems.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Chintan Sheth (Chintan Enterprise)
  • 54,UNIVERSAL INDUSTRAIL ESTATE,IB PATEL ROAD,GOREGAON-EAST, MUMBAI, Maharashtra - 400003
  • Share us via