My ExportersIndia

For Buyer

For Seller

For Help

Testing Equipment

We offer a complete product range of Gd-261-1 Closed Cup Flash Point Tester(pensky-martens), Engine Oil Distillation Tester GD-255, Oil Flash Point Tester, Petroleum Oil Water Content Tester(Distillation Method) GD-260A and Oil Water Content Tester(Karl Fischer Titration) GD-2122

Gd-261-1 Closed Cup Flash Point Tester(pensky-martens)

  • Min. Order (MOQ) 1 Set(s)
Technical parameter1. Power supply: ac 220v10%, 50hz. 2. Temperature measurement:(1) measurement range: ambient temperature250c;(2) flash point is under 104 c, bias is 2 c;flash point is above 104 c, bias is 6 c;(3) resolution: 0.1 c;(4) precision: 0.5%;3. Repeatability: 2c;4. Reproductility: 4c;5. Basic parameters:(1) temperature rising rate: as per gb/t261;(2) ignition mode: gas flame is 34 mm4. Ambient temperature: 1040c;6. Relative humidity: 80%;7. Total power consumption: not more than 350 w

Additional Information:

Payment Terms : T/T

Packaging Details : wooden case

Delivery Time : 10 days

View Complete Details

Oil Flash Point Tester

  • Min. Order (MOQ) 1 Set(s)
Product characteristics 1. Continuous heating, the power value shall be showed on the voltmeter. 2. With bijou configuration, and stainless steel operation proof, this apparatus is easy to be cleaned. 3. It is easy in operation, and precision in test. technical parameters1. Power supply: ac 220v10%, 50 hz;2. Heating device:(1) the furnace is made of sic materials; its power is 600 w;(2) heating power is adjustable in the range of 0600w;3. Sample temperature rising rate: 112c per minute, manually controlled;4. Electric stirring device:(1) stirring motor: 45tyz motor;(2) driving device: by a soft shaft;(3) stirring blade specification: 840 mm;5. Stirring speed: as per the requirement of gb/t261-2008;(1) 90120 rpm for procedure a;(2) 25010 rpm for procedure b;6. Standard oil cup: as per the requirement of gb/t261-2008;(1) inner diameter: 50.750.8 mm;(2) depth: 55.756.0 mm;(3) depth of marked line on the oil cup: 33.934.3 mm;(4) oil sample cubage: about 70 ml;7. Ignition device (flame application device):(1) ignition source: coal gas (or other civilian combustible gas);(2) aperture of ignition device: 0.8 mm;8. Thermometer: rod type mercury thermometer, as per gb/t261-2008;(1) temperature range: -5110c, each scale division is 0.5 c;(2) temperature range: 20150c, each scale division is 1.0 c;(3) temperature range: 90370c, each scale division is 2 c;9. Ambient temperature: 35c;10. Relative humidity: 85%;11. Total power consumption: not more than 650 w.

Additional Information:

Payment Terms : T/T

Packaging Details : wooden case

Delivery Time : 1

View Complete Details

Oil Flash Point Tester

  • Min. Order (MOQ) 1 Set(s)
Technical parameter1. Power supply: ac 220v10%, 50hz. 2. Temperature measurement:(1) measurement range: ambient temperature250c;(2) flash point is under 104 c, bias is 2 c;flash point is above 104 c, bias is 6 c;(3) resolution: 0.1 c;(4) precision: 0.5%;3. Basic parameters:(1) temperature rising rate: as per gb/t261;(2) ignition mode: gas flame is 34 mm; electric ignition device. 4. Ambient temperature: 1040c;5. Relative humidity: 80%;6. Total power consumption: not higher than 350 w.

Additional Information:

Payment Terms : T/T

Packaging Details : wooden case

Delivery Time : 10 days

View Complete Details

Engine Oil Distillation Tester GD-255

  • Min. Order (MOQ) 1 Set(s)
Characteristics1. Distillation Flask, made of hard glass, it can endure high temperature up to 500c.1.1. The diameter of flask ball is 69mm1mm.1.2. The diameter of flask neck is 16mm1mm.1.3. The angle between branch tube and flask neck is 753. 2. Thermometer, scale is from 0c to 360c, scale division is 1c. 3. Refrigeration bath, composed of water bath, refrigeration tube, and joint for water inlet and outlet.3.1. Refrigeration tube is made of copper with diameter of 161 and lenth of 5553mm. The inner surface of refrigeration tube is smooth and plated with Ni, Cr.3.2. The angle between refrigeration tube and water level is 15.3.3. The dimention of refrigeration bath is 180100150mm. 4. Heating system, including heating furnace, temperature adjusment circuit, and case. 5. Graduated flask and iron block.5.1. graduated flask, tow types, one is 10ml, scale division is 01ml; The other is 100ml, scale division is 1ml.5.2. Iron block, made of carbon steel, it is plated with Ni, Cr, and Cu. It is placed in the bottom of graduated flask to prevent it floating above the water. Technical Parameter1. Power Supply: AC220V10%, 50HZ.2. Heating Power: 1000W/220V, the heating rate is capable to be adjusted.3. Ambient Temperature: 1035c.4. Relative Humidity: 85%.5. Total Power Consumption: 1000W.

Additional Information:

Payment Terms : T/T

Packaging Details : wooden case

Delivery Time : 10 days

View Complete Details

Oil Flash Point Tester

  • Min. Order (MOQ) 1 Set(s)
Product characteristics1. Adopt microprocessor techniques and equipped with advanced system software, it can precisely and automatically control the testing temperature. 2. It is equiped with electric heater, anti-rust brass cup and igniton device. 3. It has a 6 digits display. Four for temperature display and the other two for time display. 4. It is easy in operation. It can automatically print out the test datas. technical parameters(i) operation condition1. Ambient temperature: 205c;2. Relative humidity: < 80%;3. Power supply: ac 220v10%, 501hz;(ii) temperature measurement1. Measurement range: ambient temperature350c;2. Test accuracy: 0.2%;3. Resolution: 0.1c;4. Repeatability:(1) flash point is lower than 150 c: error is less than 4 c;(2) flash point is higher than 150 c: error is less than 6 c;(iii) basic parameters:1. Speed rising speed: as per gb/t 3536-83;2. Ignition mode: by a gas flame (4 mm);3. Total power consumption: not more than 400 w;

Additional Information:

Payment Terms : T/T

Packaging Details : wooden case

Delivery Time : 1

View Complete Details

Petroleum Oil Water Content Tester(Distillation Method) GD-260A

  • Min. Order (MOQ) 1 Set(s)
Main parameters:1. Power supply: AC 220V10%, 50 Hz;2. Testing Range: 0.03%10% water 4. Heating power of electric furnace: 1000W2;5. Heating control: By Bidirectional silicon controlled rectifier;6. Ambient temperature: 35C;7. Relative humidity: 85%;8. Total power consumption: not more than 2200 W;

Additional Information:

Payment Terms : T/T

Packaging Details : wooden case

Delivery Time : 10 days

View Complete Details

Oil Water Content Tester(Karl Fischer Titration) GD-2122

  • Min. Order (MOQ) 1 Set(s)
Technical parameters:1. Power supply: AC 220V10, 50 Hz;2. Ambient temperature: 10 35;3. Relative humidity: 85;4. The instrument should be placed on a flat workbench. Please try your best to lower air convection;5. The instrument should be placed in a dry area if it is not used;6. Total power consumption: not more than 300 W;7. Dimention: 840600500mm, weight: 26kgs.

Additional Information:

Payment Terms : T/T

Packaging Details : wooden case

Delivery Time : 10 days

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us