Creative Building Solutions is a Lucknow (Uttar Pradesh, India) based company, which is actively engaged in offering the best space frame structure designing services. We have a team of dedicated space frame structure designing experts, who hold expertise in making the most rigid & lightweight space frame structure that can be used to span large areas with few interior supports. Many clients in Lucknow have taken advantage of our services as well.
1. GENERAL
SCOPE-Scope of the work covered with this specification is to provide all workmanship and material for the design, fabrication, packaging, transportation and erection of the steel space frame with pre-determined area, geometry and features described as per architectural drawings.The scope of the work described above comprises of the followings;Engineering design of space frame, design calculations and determination of the support reactions, preparation of shop and erection drawings.Manufacturing, surface finishes, packaging and transportation of the goods to erection site.
Assembly and erection of the space frame system under the supervision of Uskon’s qualified technical supervisor.
SUBMITTALSManufacturing commences upon client’s approval for the followings;DESIGN CALCULATIONSSpace frames are higly hyperstatic systems. Design calculations shall be made by means of computers. Software used for the design shall execute the analysis by using Matrix – Displacement ( Stiffness ) Method. Connections on the joints shall be defined so as not to transfer bending moments due to transmission of the loads by pin connected connections with bolts. Loads on the structure shall be transferred via the nodes. The design analysis may include the following loading criteria according to the project and contract conditions;
A. Dead loads ( space frame, purlins, cladding )B. Snow loadC. Service loads ( Lighting, A/C ducts, cleaning equipment, catwalks, suspended ceiling, concentrated loads, e.t.c. )D. Live loadE. Wind loadF. Seismic loadG. Temperature variation
Design calculations shall be prepared in accordance with current design rules of the DIN, EN, AISC, BS and SNIP or equivalent internationally accepted standards. Design submittals consist of load cases, loading combinations, member forces, support reactions, node deflections and assigned member types. n
| Bolt Quality | Yield Stress | Tensile Stress | Elongation After Fracture |
| Space frame bolt 8.8 | 640 N/mm2 | 800 N/mm2 | %12 |
| Space frame bolt 10.9 | 900 N/mm2 | 1000 N/mm2 | %9 |
| Purlin system bolt 6.8 | 480 N/mm2 | 600 N/mm2 |