TOP MOUNTED FLOAT OPERATED LEVEL TRANSMITTER

  • Suitable Down to 0.7 (Upto 0.5 optional) 0-150 mm upto 0-3000 mm.
  • Betterthan ±10 mm. Max. 25% of Span
  • Max. 25% of Span 12 - 36 V DC
PRINCIPLE OF OPERATION :

Level transmitter works on the principle of reed resistance/permanent magnet basis. Reedswitches function like the center arm (as shown in fig. 1) of a potentiometer. As per liquid level float moves up or down, magnet inside the float operates the reedswitches thereby causing a change in resistance value. Change in the resistance is measured by the electronics unit and conditioned as a current output of 4 to 20 mA. Signal conditioner is head mounted and of 2-wire loop powered suitable for 12 to 24 VDC giving output of 4 to 20 mA.


TECHNICAL SPECIFICATION : OUR STANDARD PRODUCT

Model (VMT-04-F65-AW) , (VMT-04-F92-AW)top mounted magnetic reed/resistance cascade type loop powered 2 wire level transmitter. Process Connection flange 78 or 120 mm diameter with 4 bolt holes of 6mm or 14 mm dia on 65 or 92 mm PCD respectively. Wetted parts flange & float stopper in SS 304. Float material SS 316L and diameter 41, 53 or 68 mm. Operating pressure 10kg/sq.cm and Temperature 125 deg.C. maximum.


SALIENT FEATURES :


    • Reedswitches are hermetically sealed-in glass under an inert gas and therefore protected from contamination.

    • Reedswitches used by us are suitable for maximum working voltage of 150 VDC and current 1 Ampere. But in our circuitry they are subjected to maximum of 3 VDC and current 1 mA in case of resistance output and maximum of 24 VDC and 20 mA when used in conjunction with a signal conditioner for current output. This ensures long life of the product.

    • Reedswitches are UL approved and ISO certified for quality management.

    • Operating temperature range of reedswitches are -40 deg. C. to 125 deg. C.

    • Reed Switches are enclosed in a moulded glass filled nylon capsule and therefore protected from mechanical shocks or damage. Moreover the stainless steel float-guide pipe, containing the PCB of reedswitches and resistances, is solidly filled with MgO Powder. Hence this is suitable for sub zero temperatures.

    • Reedswitches are protected against mechanical damage and contact corrosion & vibration.

    • Since an outer protection tube is provided (for applications like LPG, where external cage is not possible) the reedswitch sensor assembly can be replaced without disturbing the process.

    • Since the float is of 200mm dia with specific gravity -0.4 (for LPG) it will have higher buoyant force. For standard applications float shall be of 48 mm Or 68 mm in diameter.

    • Above all float is the only moving part. No wear and tear.




    APPLICATION :



        • Applicable in environment with high temp., high pressure, strong acid, strong alkaline and hazardous locations.

        • Multiple applications for textile dyeing, sewage water processing, power generating, boiler and petrochemical industries.



    View Complete Details

    Capacitance Type Level Transmitter


    A capacitance is formed between the probe and the vessel wall .As the level of the measuring medium rises or falls capacitance between the probe and vessel wall changes proportionately. A high frequency sine wave is applied between the probe and tank wall. A change of medium level will induce a change in the current of the applied sine wave. From when the capacitance in the vessel increase, impedance will decrease and current will increase and vice-versa. (Z=Resistance, C=Capacitance, F= Frequency)


    Head mounted electronics converts the capacitance variation to 4-20mA signal for long distance transmission. It is provided with trimpots for SPAN and ZERO adjustments. With no moving parts it is free from wear and tear, rugged and robust in construction. No dead zone like float based instruments.


    It must be ensured that the probe is parallel to the tank wall throughout it's length.


    TECHNICAL SPECIFICATION

    Capacitance type 3 wire Level transmitter Model (CLT-1) with non insulated probes for non-conductive liquids or PTFE Teflon insulated probes for conductive liquids.


    SALIENT FEATURES :

    1. Two parts isolated design-Electronic Module can be easily separated without removing the probe and without necessity of process shut down. So module replacement is easy.

    2. No moving parts, it is rugged and robust instrument.

    3. No dead band or dead zone like float based/ultrasonic instruments

    4. Suitable for operation from 12 to 32 VDC, with reverse polarity protection.

    5. Standard output 4-20mA.Voltage output of 0-10 optional. (For 12 V input supply output 0-5V and with 24 V supply output 0-10V)

    6. Plug and play with reference probe and rod.

    7. Remote electronics as option with 2 Metre long coaxial cable.

    8. Standard enclosure weather proof-cast Aluminium or Nylon 66. Flame proof as optional.

    9. Trim-Pots for span and zero adjustment.

    10. Kitchen & Hospital Equipments, etc.

     
    FREQUECY OF OPERATION 5 to15kHz.
    PROBE MATERIAL Stainless Steel / Teflon insulated 10/12/16 mm rod upto Max 3 Metre length
    PROCESS CONNECTION 3/4",1",1.1/2" BSP(M) or 1 "ASA 150 lbs flanged but thickness 12mm (or as per customer specification)
    POWER SUPPLY 24VDC
    OUTPUT 4 to 20 mA.(non-isolated)
    SPAN & ZERO ADJUSTMENT Trim pots
    MAX.WORKING PRESSURE 10kg/sq.cm
    MAX.WORKING TEMP. 150deg.C
    ACCURACY ±0.5%, ±1% or ±2%
    ENCLOSURE Cast aluminium weather proof with PG9 cable gland or Flame proof (IS2148-2004,Gr II A and B gases)
    CABLE SIZE 3 core, 0.75 sq.mm screened PVC cable.
    View Complete Details

    Ultra Sonic Level Transmitter

    SALIENT FEATURES :


    • SensComp, Inc. sensor module from U.S.A

    • Over Voltage Protection

    • Reverse Polarity Protection.

    • Direct or Reverse Action Adjustable at site.

    • Output : 0-5 Volts, 0-10 Volts - 3 Wire System.

    • Optional : 4 to 20 mA Output ( as a separate unit).

    • Teach-in Push Button Facility for Minimum & Maximum Value Settings.

    • Stainless Steel AISI 304 Housing Suitable for Outdoor Application.

    • Narrow Beam (15 deg) Angle.

    • 50 Khz Electronic Transducer with Integrated SMT Electronic Circuitry.

    • Range from 1-inch to 12-inch, 6-inch to 20 feet or 12 inch to 40-feet.

    • Power Requirements : 8 to 24 VDC for 5V Output / 12 to 24 VDC for 10 V Output (Maximum Current = 30 mA)

    • Operating Temperature -4 to +85 C (-40 to 185 F)


    View Complete Details
    Tell Us What are you looking for? Will call you back

    Contact Us

    • Mr. Rajesh Bhayani (D. B. Instruments & Controls)
    • 31, Patel Industrial Estate, S. V. Road, Dahisar E, Mumbai, Maharashtra - 400068
    • Share us via
    Retailer of Level Transmitters from Mumbai, Maharashtra by D. B. Instruments & Controls
    Post Buy Requirement
    DB
    Mumbai, Maharashtra, India
    Add Review

    Level Transmitters #4278417

    TOP MOUNTED FLOAT OPERATED LEVEL TRANSMITTER

    • Suitable Down to 0.7 (Upto 0.5 optional) 0-150 mm upto 0-3000 mm.
    • Betterthan ±10 mm. Max. 25% of Span
    • Max. 25% of Span 12 - 36 V DC
    PRINCIPLE OF OPERATION :

    Level transmitter works on the principle of reed resistance/permanent magnet basis. Reedswitches function like the center arm (as shown in fig. 1) of a potentiometer. As per liquid level float moves up or down, magnet inside the float operates the reedswitches thereby causing a change in resistance value. Change in the resistance is measured by the electronics unit and conditioned as a current output of 4 to 20 mA. Signal conditioner is head mounted and of 2-wire loop powered suitable for 12 to 24 VDC giving output of 4 to 20 mA.

    TECHNICAL SPECIFICATION : OUR STANDARD PRODUCT

    Model (VMT-04-F65-AW) , (VMT-04-F92-AW)top mounted magnetic reed/resistance cascade type loop powered 2 wire level transmitter. Process Connection flange 78 or 120 mm diameter with 4 bolt holes of 6mm or 14 mm dia on 65 or 92 mm PCD respectively. Wetted parts flange & float stopper in SS 304. Float material SS 316L and diameter 41, 53 or 68 mm. Operating pressure 10kg/sq.cm and Temperature 125 deg.C. maximum.

    SALIENT FEATURES :
      • Reedswitches are hermetically sealed-in glass under an inert gas and therefore protected from contamination.
      • Reedswitches used by us are suitable for maximum working voltage of 150 VDC and current 1 Ampere. But in our circuitry they are subjected to maximum of 3 VDC and current 1 mA in case of resistance output and maximum of 24 VDC and 20 mA when used in conjunction with a signal conditioner for current output. This ensures long life of the product.
      • Reedswitches are UL approved and ISO certified for quality management.
      • Operating temperature range of reedswitches are -40 deg. C. to 125 deg. C.
      • Reed Switches are enclosed in a moulded glass filled nylon capsule and therefore protected from mechanical shocks or damage. Moreover the stainless steel float-guide pipe, containing the PCB of reedswitches and resistances, is solidly filled with MgO Powder. Hence this is suitable for sub zero temperatures.
      • Reedswitches are protected against mechanical damage and contact corrosion & vibration.
      • Since an outer protection tube is provided (for applications like LPG, where external cage is not possible) the reedswitch sensor assembly can be replaced without disturbing the process.
      • Since the float is of 200mm dia with specific gravity -0.4 (for LPG) it will have higher buoyant force. For standard applications float shall be of 48 mm Or 68 mm in diameter.
      • Above all float is the only moving part. No wear and tear.
      APPLICATION :
          • Applicable in environment with high temp., high pressure, strong acid, strong alkaline and hazardous locations.
          • Multiple applications for textile dyeing, sewage water processing, power generating, boiler and petrochemical industries.
      View Complete Details

      Capacitance Type Level Transmitter

      A capacitance is formed between the probe and the vessel wall .As the level of the measuring medium rises or falls capacitance between the probe and vessel wall changes proportionately. A high frequency sine wave is applied between the probe and tank wall. A change of medium level will induce a change in the current of the applied sine wave. From when the capacitance in the vessel increase, impedance will decrease and current will increase and vice-versa. (Z=Resistance, C=Capacitance, F= Frequency)

      Head mounted electronics converts the capacitance variation to 4-20mA signal for long distance transmission. It is provided with trimpots for SPAN and ZERO adjustments. With no moving parts it is free from wear and tear, rugged and robust in construction. No dead zone like float based instruments.

      It must be ensured that the probe is parallel to the tank wall throughout it's length.

      TECHNICAL SPECIFICATION

      Capacitance type 3 wire Level transmitter Model (CLT-1) with non insulated probes for non-conductive liquids or PTFE Teflon insulated probes for conductive liquids.

      SALIENT FEATURES :
      1. Two parts isolated design-Electronic Module can be easily separated without removing the probe and without necessity of process shut down. So module replacement is easy.
      2. No moving parts, it is rugged and robust instrument.
      3. No dead band or dead zone like float based/ultrasonic instruments
      4. Suitable for operation from 12 to 32 VDC, with reverse polarity protection.
      5. Standard output 4-20mA.Voltage output of 0-10 optional. (For 12 V input supply output 0-5V and with 24 V supply output 0-10V)
      6. Plug and play with reference probe and rod.
      7. Remote electronics as option with 2 Metre long coaxial cable.
      8. Standard enclosure weather proof-cast Aluminium or Nylon 66. Flame proof as optional.
      9. Trim-Pots for span and zero adjustment.
      10. Kitchen & Hospital Equipments, etc.

       
      FREQUECY OF OPERATION 5 to15kHz.
      PROBE MATERIAL Stainless Steel / Teflon insulated 10/12/16 mm rod upto Max 3 Metre length
      PROCESS CONNECTION 3/4",1",1.1/2" BSP(M) or 1 "ASA 150 lbs flanged but thickness 12mm (or as per customer specification)
      POWER SUPPLY 24VDC
      OUTPUT 4 to 20 mA.(non-isolated)
      SPAN & ZERO ADJUSTMENT Trim pots
      MAX.WORKING PRESSURE 10kg/sq.cm
      MAX.WORKING TEMP. 150deg.C
      ACCURACY ±0.5%, ±1% or ±2%
      ENCLOSURE Cast aluminium weather proof with PG9 cable gland or Flame proof (IS2148-2004,Gr II A and B gases)
      CABLE SIZE 3 core, 0.75 sq.mm screened PVC cable.
      View Complete Details

      Ultra Sonic Level Transmitter

      SALIENT FEATURES :
      • SensComp, Inc. sensor module from U.S.A
      • Over Voltage Protection
      • Reverse Polarity Protection.
      • Direct or Reverse Action Adjustable at site.
      • Output : 0-5 Volts, 0-10 Volts - 3 Wire System.
      • Optional : 4 to 20 mA Output ( as a separate unit).
      • Teach-in Push Button Facility for Minimum & Maximum Value Settings.
      • Stainless Steel AISI 304 Housing Suitable for Outdoor Application.
      • Narrow Beam (15 deg) Angle.
      • 50 Khz Electronic Transducer with Integrated SMT Electronic Circuitry.
      • Range from 1-inch to 12-inch, 6-inch to 20 feet or 12 inch to 40-feet.
      • Power Requirements : 8 to 24 VDC for 5V Output / 12 to 24 VDC for 10 V Output (Maximum Current = 30 mA)
      • Operating Temperature -4 to +85 C (-40 to 185 F)