Our Products
The Ankle Brachial Index (ABI) is a measure of the severity of atherosclerosis in the legs but is also an independent indicator of the risk of subsequent atherothrombotic events elsewhere in the vascular system. The ABI may be used as a risk marker both in the general population free of clinical CVD and in patients with established CVD.
Continuous wave Doppler ultrasound is considered a reliable tool and was validated and accepted into routine medical practice. The literature recognises the importance of assessment in the management of a patient with chronic lower limb ulceration. The evidence from the medical literature indicates that a "normal" ABI is 0.91 or greater, a ratio below this indicating arterial disease.
Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the "normal ABI range" (0.91 to 1.4) or sometimes in the non-physiological range of above 1.4. However, Calcified leg arteries in Diabetes Mellitus or dialysis patients may yield falsely elevated ABI results.
VERSADOP Dx, ABI vascular doppler is compatible with any Windows based computer and get connected through an USB port. The software supplied helps to transfer the waveform data from the unit to the computer for storage and patient report generation.
Features :
Product Code : VERSADOP Dx
Additional Information:
Payment Terms : T/T
Packaging Details : As per client requirement
Delivery Time : One week
A low-cost pocket Ultrasound Doppler. The Uni-directional Hand Doppler model VD8M offers all the standard features of a traditional Ultrasound Vascular Doppler and, intended primarily for vascular applications.
Supplied with gel, neck cord, soft padded carry bag, software for ABI calculation and manual.
Features :
Additional Information:
Payment Terms : T/T, Western Union, ,
Delivery Time : One Week
Banking on our world class facilities and high-tech machinery, we as a Manufacturer, Exporter and Supplier, aim to enchant our customers by distinction. Automated Vascular Doppler Recorder for ABI / TBI (Versalab Auto) on offer is available in an assortment of specifications. The excellent material used in manufacturing is of top class quality. The manufacturing process is carried out by a team of skilled professionals who put their utmost efforts to ensure they produce the best possible quality.
Details :
Features :
Production Capacity :100 per month
Additional Information:
Payment Terms : L/C, T/T,
Packaging Details : As per customer requirement
Delivery Time : Immediate
The Ankle Brachial Index (ABI) is a measure of the severity of atherosclerosis in the legs but is also an independent indicator of the risk of subsequent atherothrombotic events elsewhere in the vascular system. The ABI may be used as a risk marker both in the general population free of clinical CVD and in patients with established CVD.
Continuous wave Vascular Doppler ultrasound is considered a reliable tool and was validated and accepted into routine medical practice. The literature recognises the importance of assessment in the management of a patient with chronic lower limb ulceration. The evidence from the medical literature indicates that a "normal" ABI is 0.91 or greater, a ratio below this indicating arterial disease.
Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the "normal ABI range" (0.91 to 1.4) or sometimes in the non-physiological range of above 1.4. However, Calcified leg arteries in Diabetes Mellitus or dialysis patients may yield falsely elevated ABI results.
Pulse volume recording, also known as air Plethysmography, is a noninvasive test that measures blood flow within the blood vessels or arteries. The first sign of possible abnormality is the absence of the dicrotic notch. More significant occlusions will show a decreased slope of the ascending and descending segments and a rounding of the systolic peak. More serious obstructions will show flattened waveforms.
A photoplethysmogram (PPG) is an optically obtained Plethysmogram, a volumetric measurement of an organ. The PPG Toe blood pressure and related Toe Brachial Index (TBI) are performed to assess the vascular condition of the foot by obtaining systolic pressures at the toe. Toe pressures may be useful in cases of unsuspected vascular disease and in baseline diabetic foot assessment where falsely high ankle pressures can occur due to calcification of tibial vessel.
VERSALAB Auto is capable of conducting ABI, TBI, PVR, Segmental Doppler, Upper Extremity Exam, Carotid and Penile Doppler studies. The blood pressure for the above measurements are done by a built-in mechanism and the BP measurement are validated by the software and helps the user to correct the BP measurement incase of any patient artifact. This quality control method helps to detect the systolic BP accurately.
VERSALAB Auto is compatible with any Windows operated computer for data transfer for storage and patient reports. The software has various configurations to conduct ABI/TBI, PVR, Segmental Doppler for lower extremity, Upper Extremity, Carotid examination and Penile flow studies along with the pressues indicesses.
This model is a fully automatic model that capture waveforms and blood pressues on its own for accuracy. The built-in quality control helps to detect the accurate and correct systolic BP of all the limbs. Our clients also call this equipment as diabetic doppler.
Features :
Product Code : VERSALAB Auto