Series 1211/1212 | Slack TubeĀ® Manometer -
Dwyer Series 1211 Slack Tube Manometer Model 1212 Gas Pressure Kit
Product Details:
Minimum Order Quantity 6 Piece
Meauring Range 50-0-50 CM
Tube Acrylic
Usage/Application Filter Monitoring, Duct Static Pressure For Setting Damper Position
Brand Dwyer
Available Range 50-0-50 CM
Model Dwyer Series 1211 Slack Tube Manometer Model 1212 Gas Pressure Kit
Use Filter Monitoring, Duct Static Pressure For Setting Damper Position
Dwyer Series 1211 Slack Tube Manometer Model 1212 Gas Pressure Kit
Safety Traps to Prevent Loss of Fluid
The Series 1211 Slack Tube Manometer is as accurate as the finest Laboratory U gages, but is designed to roll up compactly for easy carrying. These manometers cover a wide range of pressure readings from 4-0-4 inches up to 60-0-60 inches.
The Model 1212 Gas Pressure Kit comes supplied with a 1211-16 Slack Tube Manometer, carrying case, necessary tubing, and connection fittings for checking gas pressures in virtually all gas appliances.
PRODUCT APPLICATIONS
Filter Monitoring
Duct Static Pessure For Setting Damper Position
MODELS & ORDERING
Model Description
1211-100 Manometer, range 50-0-50, 18-1/2 oz water or mercury required.
1211-12 Manometer, range 6-0-6, 7 oz water or mercury required.
1211-120 Manometer, range 60-0-60, 57 oz water or mercury required.
1211-16 Manometer, range 8-0-8, 9 oz water or mercury required.
1211-200 Manometer, range 100-0-100, 35 oz water or mercury required.
1211-24 Manometer, range 12-0-12, 12-1/2 oz water or mercury required.
1211-30 Manometer, range 15-0-15, 15 oz water or mercury required.
1211-36 Manometer, range 18-0-18, 17-1/2 oz water or mercury required.
1211-48 Manometer, range 24-0-24, 22-1/2 oz water or mercury required.
1211-50 Manometer, range 25-0-25, 11 oz water or mercury required.
1211-60 Manometer, range 30-0-30, 27 oz water or mercury required.
1211-72 Manometer, range 36-0-36, 32 oz water or mercury required.
1211-8 Manometer, range 4-0-4, 6 oz water or mercury required.
1212 Gas pressure kit.
FEATURES
Rolls Up For Easy Storage And Transport
Over Pressure Safety Traps To Prevent Loss Of Fluid Due To Over Range Pressures Or Surges In Pressure
OPTIONS
Included with the 1212 kit:
1 - #1211-16 Slack Tube Manometer, Reads Pressure to 16" Water.*
1 - Carrying Case, Plastic, 8-1/2" x 7" x 3-1/8".
1 - 1 oz. Bottle Fluorescein Green Color Concentrate With Wetting Agent.
1 - 1/8" Pipe Thread Rubber Tubing Adapters.
1 - 1/8" to 1/4" Pipe Thread Bushing.
1 - 3 FT Length 3/16" Rubber Tubing.
1 - Rubber Tubing Adapter To Fit Standard 7/16" Diameter Pud.
*Other Ranges Available.
ACCESSORIES
Model Number Description
A-126 1 oz dispenser bottle fluorescein green color concentrate.
A-401 Plastic carrying case (7-9/16" x 5-7/8" x 2-13/16").
A-315 Gage connector, shutoff type, for 3/16" rubber tubing.
A-332 Brass adapter, 1/8" female NPT to 1/4" male NPT.
A-339 Adapter, brass, 1/8" NPT to 3/16" rubber and 1/8" ID plastic tubing.
A-202 Rubber Latex tubing. 3/16" ID, lengths to 50'.
A-413 Steel Carrying case for portable Draft Gages 104-8, 104-10 and 48" And Larger Slack Tube Manometers - 18-1/2" x 4-3/8" x 2-1/4"
Additional Information:
Payment Terms : L/C, D/A, D/P
Delivery Time : 10-15 Week
Series 1211/1212 Slack Tube Manometer
Product Details:
Minimum Order Quantity6 Piece
Meauring Range50-0-50 CM
TubeAcrylic
Usage/ApplicationFilter Monitoring, Duct Static Pressure For Setting Damper Position
BrandDwyer
Available Range50-0-50 CM
ModelSeries 1211/1212 Slack Tube Manometer
UseFilter Monitoring, Duct Static Pressure For Setting Damper Position
Series 1211/1212 Slack Tube Manometer
SERIES 1211/1212 SLACK TUBE MANOMETERS
Safety Traps to Prevent Loss of Fluid
The Series 1211 Slack Tube Manometer is as accurate as the finest Laboratory U gages, but is designed to roll up compactly for easy carrying. These manometers cover a wide range of pressure readings from 4-0-4 inches up to 60-0-60 inches.
The Model 1212 Gas Pressure Kit comes supplied with a 1211-16 Slack Tube Manometer, carrying case, necessary tubing, and connection fittings for checking gas pressures in virtually all gas appliances.
PRODUCT APPLICATIONS
Filter Monitoring
Duct Static Pessure For Setting Damper Position
MODELS & ORDERING
ModelDescription
1211-100Manometer, range 50-0-50, 18-1/2 oz water or mercury required.
1211-12Manometer, range 6-0-6, 7 oz water or mercury required.
1211-120Manometer, range 60-0-60, 57 oz water or mercury required.
1211-16Manometer, range 8-0-8, 9 oz water or mercury required.
1211-200Manometer, range 100-0-100, 35 oz water or mercury required.
1211-24Manometer, range 12-0-12, 12-1/2 oz water or mercury required.
1211-30Manometer, range 15-0-15, 15 oz water or mercury required.
1211-36Manometer, range 18-0-18, 17-1/2 oz water or mercury required.
1211-48Manometer, range 24-0-24, 22-1/2 oz water or mercury required.
1211-50Manometer, range 25-0-25, 11 oz water or mercury required.
1211-60Manometer, range 30-0-30, 27 oz water or mercury required.
1211-72Manometer, range 36-0-36, 32 oz water or mercury required.
1211-8Manometer, range 4-0-4, 6 oz water or mercury required.
1212Gas pressure kit.
FEATURES
Rolls Up For Easy Storage And Transport
Over Pressure Safety Traps To Prevent Loss Of Fluid Due To Over Range Pressures Or Surges In Pressure
OPTIONS
Included with the 1212 kit:
1 - #1211-16 Slack Tube Manometer, Reads Pressure to 16" Water.*
1 - Carrying Case, Plastic, 8-1/2" x 7" x 3-1/8".
1 - 1 oz. Bottle Fluorescein Green Color Concentrate With Wetting Agent.
1 - 1/8" Pipe Thread Rubber Tubing Adapters.
1 - 1/8" to 1/4" Pipe Thread Bushing.
1 - 3 FT Length 3/16" Rubber Tubing.
1 - Rubber Tubing Adapter To Fit Standard 7/16" Diameter Pud.
*Other Ranges Available.
ACCESSORIES
Model Number Description
A-126 1 oz dispenser bottle fluorescein green color concentrate.
A-401 Plastic carrying case (7-9/16" x 5-7/8" x 2-13/16").
A-315 Gage connector, shutoff type, for 3/16" rubber tubing.
A-332 Brass adapter, 1/8" female NPT to 1/4" male NPT.
A-339 Adapter, brass, 1/8" NPT to 3/16" rubber and 1/8" ID plastic tubing.
A-202 Rubber Latex tubing. 3/16" ID, lengths to 50'.
A-413 Steel Carrying case for portable Draft Gages 104-8, 104-10 and 48" And Larger Slack Tube Manometers - 18-1/2" x 4-3/8" x 2-1/4"
Additional Information:
Payment Terms : L/C, D/A, D/P
Delivery Time : 10-15 Week