Thermocouple T C

  • It employes two dissimilar metals
  • When two such dissimilar metals welded together at one end and subjected to heat, it develops a small DC voltage (EMF), corresponding to temperature difference between hot junction (measuring junction) and cold junction (reference junction).
  • The temperature - EMF characteristics have an established pattern for different type of hermocouple elements like, T, J, K, N, E, R, S, etc.
  • Temperature - EMF characteristics conform toANSI MC 96.1 / IEC 584 / DIN 43710 standards.
  • It employs high purity electrical resistance wire, non inductively wound on ceramic or glass base.
  • When RTD element is subjected to heat, it changes its electrical resistance value, corresponding to variation in temperature and its thermal coefficient () (Alpha).
  • The temperature resistance characteristics have an established pattern for different resistance elements, like Copper, Nickel, Platinum etc.
  • Most commonly used resistance element is Platinum known as Pt 100 (100 ohms at 0C).
  • Temperature resistance characteristics conform to DIN 43760 / IEC 751 / BSS 1904 / JIS C1604 standards.
  • Conventional thermocouple or RTD elements pass through multi bore insulators, encased in outer protection sheath and connected to temperature measuring instrument.
  • Mineral insulated (MI) sensors are insulated with tightly compacted high purity magnesium oxide powder, simplex or duplex, enclosed in various metal sheaths and connected to temperature measuring intrument.
View Complete Details

Multipoint Element Assembly

These T/Cs or RTDs are designed to measure temperatures of medium at different levels in vertical column for Petrochemical, Fertilizer, Steel & other industries.
METAL SHEATHTHERMO-COUPLE
  • MINERAL INSULATED
  • Type K, T, E, J
  • Sheath: Dia 1 mm to 12.7 mm OD in various materials.
  • Simplex (up to 12.7 mm OD) & Duplex (3 to 12.7 mm OD)
  • Junction : Grounded or Insulated (Un-Grounded)
METAL SHEATH RTD
  • MINERAL INSULATED
  • Type PT 100 (100 ohms at 0C).
  • Simplex or Duplex - 2 or 3 wire system
  • Sheath: Dia 4 mm, 6 mm & 8 mm in SS 316.
MOUNTING
  • FLANGED or THREADED with mechanical fittings.
ENCLOSURE
  • Cast Aluminium with cable entry.
  • Purge Tube: (optional) with proper mountings and inlet threaded commection.
  • Protection: IP 65, Flame Proof Gr IIA, IIB or IIC, Increased Safety.
  • Thermination : Brass connections with markings for polarity, colour codes and type of Thermocouple / RTD.
CONSTRUCTION
  • Elements pass through multibore metal disc fittings, bunched together with SS binding wire. Thermocouples (above 6 mm OD) could be silver brazed - if required.
LENGTH
  • From few feet onwards without thermowell.
  • Upto 7 Mts with thermowell. (Larger lengths require special transportation facility)

View Complete Details

Mineral Insulated Elements

Mineral insulated (MI) sensors are insulated with tightly compacted magnesium oxide powder enclosed in various metal sheaths.

Hot Junction is formed in inert gas atmosphere and tested for Leakage with Nitrogen gas under pressure.

  1. Simplex or Duplex assemblies.
  2. Vibration-Proof, Fast-Response, High Insulation Resistance, Accurate and Stable. Termination : Pot Seal with Flying Lead (PSFL), Male Female Connecor (MFC), Connection Head (HEAD) & Junction Box - for multipoint assembly - (J B).
  3. Sheaths can be bent, twisted and flattended to suit application.
  4. Length can be from few inches to several meters.
  • T/C type : K, T, J, E, N with sheath diameters from 1 mm to 19.1 mm.
  • T/C Sheath material : SS 304, 316, 310, 321, 446, *Inconel 600, *Incolloy 800/825.
  • T/C Junctions can be Grounded or Insulated (Un-Grounded).
  • RTD type : PT 100 simplex or duplex, two or three wire system.

SHEATH
DIAMETER
mm

SIMPLEX

DUPLEX
INSULATION
RESISTANCE (MINI)
Meg Ohm at room temp.

TERMINATION

RTD
DIMENSIONS
T/C RTD
1. 1/5.
2
- YES NO 10 at 100 V DC PSFL, MFC, HEAD, JB  
3 - YES YES 100 at 500 V DC PSFL, MFC, HEAD, JB  
6 6 YES YES 100 at 500 V DC PSFL, MFC, HEAD, JB 6x60 mm bulb with 5mm OD SS 316MI cable extention
8 8 YES YES 500 at 500 V DC PSFL, MFC, HEAD, JB 8x60 mm bulb with 5mm OD SS 316MI cable extention
12.7 - YES YES 500 at 500 V DC PSFL, HEAD  
IR test at elevated temperature also could be provided, if required.










View Complete Details

Skin Thermocoples

Skin Thermocoples
  • The Skin Thermocouples is Designed to Sense Surface Temperature of Boiler or Process Tubes.
  • Typical Skin Thermocouple Assembly comprises of MI Thermocouple, welding pad and strap, intermediate loop (twice pipe diameter), adjustable threaded adapter and heavy duty enclosure.
ELEMENTS K, Simplex or Duplex
SHEATH SS 310, 446, *INCONEL 600, *INCOLOY 800/825 OD 6 mm to 12.7 mm
JUNCTION GROUNDED or UN-GROUNDED
PAD SIZE 2" x 1/2" x 1/4" ; 1" x 1" x 3/4" Shaped to match pipe curvature
CLAMP / STRAP 1 1/2" x 1/2" x 1/8"For anchoring Thermocouple
MOUNTING Standard 1" NPT in SS 316
ENCLOSURE Die Cast Aluminium, Cast Steel with Compression Fitting for gripping Thermocouple
  • Thermocouple Junction is welded in the centre of pad
  • Thermocouple is inserted in the pad SKIN RTDs (MI) also could be offered on specific requirement. * Manufacturers' Trade Name

THERMOCOUPLE
TYPE
TEMPERATURE
RANGE °C
STANDARD
Whichevere is Greater
SPECIAL
Whichever is Greater
T 0-350 ± 1°C or ± 0.75% ± 0.5°C or ± 0.4%
J 0-750 ± 2.2°C or ± 0.75% ± 1.1°C or ± 0.4%
E 0-900 ± 1.7°C or ± 0.5% ± 1°C or ± 0.4%
K 0-1250 ± 2.2°C or ± 0.75% ± 1.1°C or ± 0.4%
R or S 0-1450 ± 1.5°C or ± 0.25% ± 0.6°C or ± 0.1%
B 800-1700 ± 0.5% ---
   
Reference junction 0°C. As per ANSI MC 96.1 (1982)

 

Limits of Error for Platinum-RTD Elements
MEASURING
TEMPERATURE

°C
PERMISSIBLE DEVIATIONS
CLASS A CLASS B
°C °C
-200 ± 0.24 ± 0.55 ± 0.56 ± 1.3
-100 ± 0.14 ± 0.35 ± 0.32 ± 0.8
0 ± 0.06 ± 0.15 ± 0.12 ± 0.3
100 ± 0.13 ± 0.35 ± 0.30 ± 0.8
200 ± 0.20 ± 0.55 ± 0.48 ± 1.3
300 ± 0.27 ± 0.75 ± 0.64 ± 1.8
400 ± 0.33 ± 0.95 ± 0.79 ± 2.3
500 ± 0.38 ± 1.15 ± 0.93 ± 2.8
600 ± 0.43 ± 1.35 ± 1.06 ± 3.3
    As per DIN 43760, BS 1904






View Complete Details

Thermowell

  • THERMOWELLprovides complete protection for the sensor (Temperature, Pressure etc) elements.
  • THERMOWELL is designed considering optimum Pressure, Temperature, critical Frequency, the nature of Media (abrasive, corrosive etc) and intensity of flow of media.
  • THERMOWELL allows removing or replacing of Sensing Instrument without draining or shutting down of process.

Most Commonly Used - THERMOWELLS

  • THREADED THERMOWELL drilled from Bar Stock OR BUILT-IN.
  • FLANGED THERMOWELL drilled from Bar Stock & welded flange
  • FLANGED THERMOWELL drilled from Bar Stock and in one piece.

THREADED THERMOWELL - DRILLED BAR STOCK

 
 LEG EXTN.
T
mm
 PROC.CONN.
NPT / BSP 
 INSIDE
BORE DIA

mm  
  OUTSIDE DIAMETER MAX mm   LENGTH MAX
U mm 
STRAIGHT  STEP  TAPER 
     50
TO
225
1/2" 6.5 16  16 - 12  16 - 12  300
1/2" 9.5 16  --  --  300
3/4" 6.5 19  19 - 12  19 - 12  400
3/4" 9.5 19  --  --  400
1" 6.5 25  25 - 12  25 - 12  600
1" 9.5 25  25 - 16  25 - 16  600
      * STANDARD INSTRUMENT CONNECTION (IC) : 1/2" NPT/BSP/METRIC THREADS
* LONGER 'U' LENGTHS OFFERED BY BUTT WELDED MULTIPLE SECTIONS
* Other Requirements - Please Specify 










View Complete Details

Rtd Assembly

We are offering temperature elements thermocouples rtd assemblies. It employes two dissimilar metals when two such dissimilar metals welded together at one end and subjected to heat, it develops a small dc voltage (emf), corresponding to temperature difference between hot junction (measuring junction) and cold junction (reference junction). the temperature - emf characteristics have an established pattern for different type of hermocouple elements like, t, j, k, n, e, r, s, etc. temperature - emf characteristics conform toansi mc 96.1 iec 584 din 43710 standards
View Complete Details

Thermocouple Assembly

Backed by a team of highly experienced professionals, we are involved in providing a wide range of thermocouple assembly.
View Complete Details

Thermocouple Cable

Over the years of experience in the industry, we have been able to provide the customers with a commendable range of thermocouple cable.
View Complete Details

Skin Thermocouples

WE ARE NEED Skin Thermocouples M It employes two dissimilar metals When two such dissimilar metals welded together at one end and subjected to heat, it develops a small DC voltage (EMF), corresponding to temperature difference between hot junction (measuring junction) and cold junction (reference junction). The temperature - EMF characteristics have an established pattern for different type of hermocouple elements like, T, J, K, N, E, R, S, etc. Temperature - EMF characteristics conform toANSI MC 96.1 IEC 584 DIN 43710 standards
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Browse Our Products list of Electrical & Electronics Corporation Mumbai, Maharashtra
Post Buy Requirement
E&
Mumbai, Maharashtra, India
Add Review

Our Products #50876

Thermocouple T C

  • It employes two dissimilar metals
  • When two such dissimilar metals welded together at one end and subjected to heat, it develops a small DC voltage (EMF), corresponding to temperature difference between hot junction (measuring junction) and cold junction (reference junction).
  • The temperature - EMF characteristics have an established pattern for different type of hermocouple elements like, T, J, K, N, E, R, S, etc.
  • Temperature - EMF characteristics conform toANSI MC 96.1 / IEC 584 / DIN 43710 standards.
  • It employs high purity electrical resistance wire, non inductively wound on ceramic or glass base.
  • When RTD element is subjected to heat, it changes its electrical resistance value, corresponding to variation in temperature and its thermal coefficient () (Alpha).
  • The temperature resistance characteristics have an established pattern for different resistance elements, like Copper, Nickel, Platinum etc.
  • Most commonly used resistance element is Platinum known as Pt 100 (100 ohms at 0C).
  • Temperature resistance characteristics conform to DIN 43760 / IEC 751 / BSS 1904 / JIS C1604 standards.
  • Conventional thermocouple or RTD elements pass through multi bore insulators, encased in outer protection sheath and connected to temperature measuring instrument.
  • Mineral insulated (MI) sensors are insulated with tightly compacted high purity magnesium oxide powder, simplex or duplex, enclosed in various metal sheaths and connected to temperature measuring intrument.
View Complete Details

Multipoint Element Assembly

These T/Cs or RTDs are designed to measure temperatures of medium at different levels in vertical column for Petrochemical, Fertilizer, Steel & other industries.
METAL SHEATHTHERMO-COUPLE
  • MINERAL INSULATED
  • Type K, T, E, J
  • Sheath: Dia 1 mm to 12.7 mm OD in various materials.
  • Simplex (up to 12.7 mm OD) & Duplex (3 to 12.7 mm OD)
  • Junction : Grounded or Insulated (Un-Grounded)
METAL SHEATH RTD
  • MINERAL INSULATED
  • Type PT 100 (100 ohms at 0C).
  • Simplex or Duplex - 2 or 3 wire system
  • Sheath: Dia 4 mm, 6 mm & 8 mm in SS 316.
MOUNTING
  • FLANGED or THREADED with mechanical fittings.
ENCLOSURE
  • Cast Aluminium with cable entry.
  • Purge Tube: (optional) with proper mountings and inlet threaded commection.
  • Protection: IP 65, Flame Proof Gr IIA, IIB or IIC, Increased Safety.
  • Thermination : Brass connections with markings for polarity, colour codes and type of Thermocouple / RTD.
CONSTRUCTION
  • Elements pass through multibore metal disc fittings, bunched together with SS binding wire. Thermocouples (above 6 mm OD) could be silver brazed - if required.
LENGTH
  • From few feet onwards without thermowell.
  • Upto 7 Mts with thermowell. (Larger lengths require special transportation facility)

View Complete Details

Mineral Insulated Elements

Mineral insulated (MI) sensors are insulated with tightly compacted magnesium oxide powder enclosed in various metal sheaths.

Hot Junction is formed in inert gas atmosphere and tested for Leakage with Nitrogen gas under pressure.

  1. Simplex or Duplex assemblies.
  2. Vibration-Proof, Fast-Response, High Insulation Resistance, Accurate and Stable. Termination : Pot Seal with Flying Lead (PSFL), Male Female Connecor (MFC), Connection Head (HEAD) & Junction Box - for multipoint assembly - (J B).
  3. Sheaths can be bent, twisted and flattended to suit application.
  4. Length can be from few inches to several meters.
  • T/C type : K, T, J, E, N with sheath diameters from 1 mm to 19.1 mm.
  • T/C Sheath material : SS 304, 316, 310, 321, 446, *Inconel 600, *Incolloy 800/825.
  • T/C Junctions can be Grounded or Insulated (Un-Grounded).
  • RTD type : PT 100 simplex or duplex, two or three wire system.

SHEATH
DIAMETER
mm

SIMPLEX

DUPLEX
INSULATION
RESISTANCE (MINI)
Meg Ohm at room temp.

TERMINATION

RTD
DIMENSIONS
T/C RTD
1. 1/5.
2
- YES NO 10 at 100 V DC PSFL, MFC, HEAD, JB  
3 - YES YES 100 at 500 V DC PSFL, MFC, HEAD, JB  
6 6 YES YES 100 at 500 V DC PSFL, MFC, HEAD, JB 6x60 mm bulb with 5mm OD SS 316MI cable extention
8 8 YES YES 500 at 500 V DC PSFL, MFC, HEAD, JB 8x60 mm bulb with 5mm OD SS 316MI cable extention
12.7 - YES YES 500 at 500 V DC PSFL, HEAD  
IR test at elevated temperature also could be provided, if required.










View Complete Details

Skin Thermocoples

Skin Thermocoples
  • The Skin Thermocouples is Designed to Sense Surface Temperature of Boiler or Process Tubes.
  • Typical Skin Thermocouple Assembly comprises of MI Thermocouple, welding pad and strap, intermediate loop (twice pipe diameter), adjustable threaded adapter and heavy duty enclosure.
ELEMENTS K, Simplex or Duplex
SHEATH SS 310, 446, *INCONEL 600, *INCOLOY 800/825 OD 6 mm to 12.7 mm
JUNCTION GROUNDED or UN-GROUNDED
PAD SIZE 2" x 1/2" x 1/4" ; 1" x 1" x 3/4" Shaped to match pipe curvature
CLAMP / STRAP 1 1/2" x 1/2" x 1/8"For anchoring Thermocouple
MOUNTING Standard 1" NPT in SS 316
ENCLOSURE Die Cast Aluminium, Cast Steel with Compression Fitting for gripping Thermocouple
  • Thermocouple Junction is welded in the centre of pad
  • Thermocouple is inserted in the pad SKIN RTDs (MI) also could be offered on specific requirement. * Manufacturers' Trade Name

THERMOCOUPLE
TYPE
TEMPERATURE
RANGE °C
STANDARD
Whichevere is Greater
SPECIAL
Whichever is Greater
T 0-350 ± 1°C or ± 0.75% ± 0.5°C or ± 0.4%
J 0-750 ± 2.2°C or ± 0.75% ± 1.1°C or ± 0.4%
E 0-900 ± 1.7°C or ± 0.5% ± 1°C or ± 0.4%
K 0-1250 ± 2.2°C or ± 0.75% ± 1.1°C or ± 0.4%
R or S 0-1450 ± 1.5°C or ± 0.25% ± 0.6°C or ± 0.1%
B 800-1700 ± 0.5% ---
   
Reference junction 0°C. As per ANSI MC 96.1 (1982)

 

Limits of Error for Platinum-RTD Elements
MEASURING
TEMPERATURE

°C
PERMISSIBLE DEVIATIONS
CLASS A CLASS B
°C °C
-200 ± 0.24 ± 0.55 ± 0.56 ± 1.3
-100 ± 0.14 ± 0.35 ± 0.32 ± 0.8
0 ± 0.06 ± 0.15 ± 0.12 ± 0.3
100 ± 0.13 ± 0.35 ± 0.30 ± 0.8
200 ± 0.20 ± 0.55 ± 0.48 ± 1.3
300 ± 0.27 ± 0.75 ± 0.64 ± 1.8
400 ± 0.33 ± 0.95 ± 0.79 ± 2.3
500 ± 0.38 ± 1.15 ± 0.93 ± 2.8
600 ± 0.43 ± 1.35 ± 1.06 ± 3.3
    As per DIN 43760, BS 1904






View Complete Details

Thermowell

  • THERMOWELLprovides complete protection for the sensor (Temperature, Pressure etc) elements.
  • THERMOWELL is designed considering optimum Pressure, Temperature, critical Frequency, the nature of Media (abrasive, corrosive etc) and intensity of flow of media.
  • THERMOWELL allows removing or replacing of Sensing Instrument without draining or shutting down of process.

Most Commonly Used - THERMOWELLS

  • THREADED THERMOWELL drilled from Bar Stock OR BUILT-IN.
  • FLANGED THERMOWELL drilled from Bar Stock & welded flange
  • FLANGED THERMOWELL drilled from Bar Stock and in one piece.

THREADED THERMOWELL - DRILLED BAR STOCK

 
 LEG EXTN.
T
mm
 PROC.CONN.
NPT / BSP 
 INSIDE
BORE DIA

mm  
  OUTSIDE DIAMETER MAX mm   LENGTH MAX
U mm 
STRAIGHT  STEP  TAPER 
     50
TO
225
1/2" 6.5 16  16 - 12  16 - 12  300
1/2" 9.5 16  --  --  300
3/4" 6.5 19  19 - 12  19 - 12  400
3/4" 9.5 19  --  --  400
1" 6.5 25  25 - 12  25 - 12  600
1" 9.5 25  25 - 16  25 - 16  600
      * STANDARD INSTRUMENT CONNECTION (IC) : 1/2" NPT/BSP/METRIC THREADS
* LONGER 'U' LENGTHS OFFERED BY BUTT WELDED MULTIPLE SECTIONS
* Other Requirements - Please Specify 










View Complete Details

Rtd Assembly

We are offering temperature elements thermocouples rtd assemblies. It employes two dissimilar metals when two such dissimilar metals welded together at one end and subjected to heat, it develops a small dc voltage (emf), corresponding to temperature difference between hot junction (measuring junction) and cold junction (reference junction). the temperature - emf characteristics have an established pattern for different type of hermocouple elements like, t, j, k, n, e, r, s, etc. temperature - emf characteristics conform toansi mc 96.1 iec 584 din 43710 standards
View Complete Details

Thermocouple Assembly

Backed by a team of highly experienced professionals, we are involved in providing a wide range of thermocouple assembly.
View Complete Details

Thermocouple Cable

Over the years of experience in the industry, we have been able to provide the customers with a commendable range of thermocouple cable.
View Complete Details

Skin Thermocouples

WE ARE NEED Skin Thermocouples M It employes two dissimilar metals When two such dissimilar metals welded together at one end and subjected to heat, it develops a small DC voltage (EMF), corresponding to temperature difference between hot junction (measuring junction) and cold junction (reference junction). The temperature - EMF characteristics have an established pattern for different type of hermocouple elements like, T, J, K, N, E, R, S, etc. Temperature - EMF characteristics conform toANSI MC 96.1 IEC 584 DIN 43710 standards
View Complete Details
Tell Us What are you looking for? Will call you back