Post Buy Requirement
EM
Hyderabad, Telangana, India
Add Review

Our Products #3836641

K Rated Transformer

  • Application The IT hub power systems, sensitive installations and communication systems.
  • Features high efficiency with low flux density and current density to reduce the losses and heat Primary 3wire system and output 4wire system with zig-zag winding to reduce the imbalance and non linearity.
  • Range 5KVA TO 50KVA single phase to 3phase
  • Frequency 50/60/400Hz
  • Voltages Primary 1200V Secondary 1200V
  • Termination Flying leads bus bars and barrier (Wago)
  • Di-Electric Strength 100V to 3.5KV AC.
View Complete Details

Loading Reactor

  • Features Single phase and 3phase shell type and core type. Designed with laminations E&I, UI or cut strips or C cores with suitable air gap to avoid saturation with given current or voltage.
  • Frequency 50/60/400Hz
  • Voltage 1200V
  • Range 10 to 100KVAR
  • Di-Electric Strength 3.5KV
View Complete Details

Saturable Reactors

  • Features control the inductance to the AC windings this will help in regulating AC voltage.
  • Frequency 50/60/400Hz
  • Voltage up to 12000V
  • Application agnetic amplifier based regulated power supply and AC voltage control.
  • Range 1 to 50Amper
  • Di-Electric Strength 3.5KV
View Complete Details

Scott Connected Transformer

  • Frequency 50/60/400Hz
  • Range 5VA to 500KVA
  • Voltages Primary 1200V Secondary 1200V
  • Di-Electric Strength 100V to 3.5KV AC
  • Termination Flying leads, bus bars and barriers (Wago)
  • Application Lighting application and furnace application.
View Complete Details

Auto Tap Transformer

  • Frequency 20 to 1000 HZ.
  • Phase 1 Phase, 3 Phase
  • Enclosure Open type IP 00 or enclosure with required IP protection
  • Features suitable turns &taps in 1 phase and 3 phase at any frequency and voltages, higher efficiency, good regulation & coupling or impedance.
  • Range 1 VA to 1000 KVA Open dry type
View Complete Details

Control Transformers

  • Phase F Single Phase, 3 Phases
  • Enclosure Open type IP00
  • Features For inductive loads such as relays and use for control circuits in machines and equipment’s, And panel boards.
  • Range 10 VA to 5KVA dry type
  • Frequency 20 HZ to 1000 Hz
  • Primary Voltage Up 1200V
  • Secondary Voltage 1V to 1200V
View Complete Details

High Frequency Inductor

  • Features designed with Amorphous, Nano crystalline or C cut cores or distributed air gap (Powder Iron cores) or Ferrite with air gaps.
  • Range 1Amper to 500 Amperes.
  • Inductance uH TO H
  • Frequency 50Hz to 500 KHz
  • Di-Electric Strength 3.5KV
View Complete Details

Inverter Transformer

  • Features These transformers are designed with low loss cores with higher leakage for reducing distortions.
  • Range 100VA TO 100KVA
  • Frequency 50/60/400Hz
  • Primary Voltage up to 1200V
  • Secondary Voltage up to 1200V
  • Di-Electrical at Strength 100V to 3.5 KV ac
View Complete Details

Line Filter

  • Frequency 10 KHz to 10MHz
  • Voltage 1200V
  • Features designed high permeability, suitable air gap in magnetic path to avoid saturation.
  • Range 1A to 100 Amperes single phase and three phase.
  • Di-Electric strength 3.5KV
View Complete Details

Current Auxiliary And Sensing Transformers

  • Frequency 50/60/400Hz.
  • Features Bus bar or single turn or multi turns primary with suitable high grade low loss toroidal cores/E&I lamination, winding is designed for the required current and Knee voltage (saturation of flux and ISF
  • Range 1-10000 Amperes.
  • Burden 0.5VA to 50VA.
  • Di- Electric strength 100V TO 3.5KV.
  • Application Current measurement and current sensing.
View Complete Details

DC Smoothing Filter

  • Features The chokes are designed depending on the current DC and inductance for the energy requirement 0.5 LI Square.
  • Range 0.1 to 5000 joules
  • Current 0.1 to 5000Amperes DC
  • Frequency 100 to 5000Hz Ripple
  • Di- Electric Strength 3.5KV
View Complete Details

Harmonic And Detuned Filter

  • Frequency 50 / 60 Hz
  • Voltage 380 to 480V AC
  • Range KVAR to 500KW
  • No of phase 3 phase
  • Detune factor: 5.6 to 14% of voltage
  • Thermal current 110% of the rated
  • Inductance tolerance +or-3%
  • Operating ambient -20 to +50C
View Complete Details

Power Supply Transformer

  • Phase Singe Phase, Three Phase
  • Features currents result in low power factor & lot of harmonics, require additional consideration in design.
  • Range 1 VA to 250 KVA
  • Frequency 20 to 500, 000 Hz
  • Enclosure Generally open type IP00 dry type
View Complete Details

Constant Voltage Transformer

  • Frequency 50/60/400Hz
  • Phase F Single Phase, 3 Phase
  • Enclosure Open type IP00 or with enclosure
  • Secondary Voltage 1V to 1200V
  • Features Low losses with higher saturation flux suitable shunt adjustments in design and practice gives the required constant voltage output at designated tap.
  • Range 100 VA to 5KVA dry type
  • Terminals Flying Leads or Barrier type shrouded studded lugs
  • Primary Voltage 50 to 1200V
View Complete Details

High Frequency Transformer

  • Frequency 5Kilo cycles to 500Kilo cycles.
  • Features To reduce the high frequency losses (Eddy current) core material used very thin amorphous, Nano crystalline and ferrite cores, To reduce the leakage suitable winding techniques are used.
  • Range 1VA TO 50KVA
  • Voltages Primary up to 1200V To Secondary 1200V
  • Di-Electric Strength 100V to 3.5KV AC.
  • Application DC To DC converters (Buck Boost and SMPS Transformers)
View Complete Details

Isolation Transformer

  • Phase F Single Phase, 3 Phase
  • Range 1 VA to 500 KVA dry type
  • Frequency 20 HZ to 1000 Hz
  • Primary Voltage 1200V
  • Secondary Voltage 1V to 30 KV
  • Di-Electrical at Strength 100V to 30 KV ac
View Complete Details

Reactors Chokes And Coils

  • Features Heat dissipation to reduce the temperature rise, Improves True power factor, reducing harmonic enhances the load motor life as the result of less loss.
  • Range 1 to 1000KVR
  • Working Voltage up to 1200V
  • Current rating 1 to 3000A
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Browse Our Products list of Electro Magnetic Devices Hyderabad, Telangana
Post Buy Requirement
EM
Hyderabad, Telangana, India
Add Review

Our Products #3836641

K Rated Transformer

  • Application The IT hub power systems, sensitive installations and communication systems.
  • Features high efficiency with low flux density and current density to reduce the losses and heat Primary 3wire system and output 4wire system with zig-zag winding to reduce the imbalance and non linearity.
  • Range 5KVA TO 50KVA single phase to 3phase
  • Frequency 50/60/400Hz
  • Voltages Primary 1200V Secondary 1200V
  • Termination Flying leads bus bars and barrier (Wago)
  • Di-Electric Strength 100V to 3.5KV AC.
View Complete Details

Loading Reactor

  • Features Single phase and 3phase shell type and core type. Designed with laminations E&I, UI or cut strips or C cores with suitable air gap to avoid saturation with given current or voltage.
  • Frequency 50/60/400Hz
  • Voltage 1200V
  • Range 10 to 100KVAR
  • Di-Electric Strength 3.5KV
View Complete Details

Saturable Reactors

  • Features control the inductance to the AC windings this will help in regulating AC voltage.
  • Frequency 50/60/400Hz
  • Voltage up to 12000V
  • Application agnetic amplifier based regulated power supply and AC voltage control.
  • Range 1 to 50Amper
  • Di-Electric Strength 3.5KV
View Complete Details

Scott Connected Transformer

  • Frequency 50/60/400Hz
  • Range 5VA to 500KVA
  • Voltages Primary 1200V Secondary 1200V
  • Di-Electric Strength 100V to 3.5KV AC
  • Termination Flying leads, bus bars and barriers (Wago)
  • Application Lighting application and furnace application.
View Complete Details

Auto Tap Transformer

  • Frequency 20 to 1000 HZ.
  • Phase 1 Phase, 3 Phase
  • Enclosure Open type IP 00 or enclosure with required IP protection
  • Features suitable turns &taps in 1 phase and 3 phase at any frequency and voltages, higher efficiency, good regulation & coupling or impedance.
  • Range 1 VA to 1000 KVA Open dry type
View Complete Details

Control Transformers

  • Phase F Single Phase, 3 Phases
  • Enclosure Open type IP00
  • Features For inductive loads such as relays and use for control circuits in machines and equipment’s, And panel boards.
  • Range 10 VA to 5KVA dry type
  • Frequency 20 HZ to 1000 Hz
  • Primary Voltage Up 1200V
  • Secondary Voltage 1V to 1200V
View Complete Details

High Frequency Inductor

  • Features designed with Amorphous, Nano crystalline or C cut cores or distributed air gap (Powder Iron cores) or Ferrite with air gaps.
  • Range 1Amper to 500 Amperes.
  • Inductance uH TO H
  • Frequency 50Hz to 500 KHz
  • Di-Electric Strength 3.5KV
View Complete Details

Inverter Transformer

  • Features These transformers are designed with low loss cores with higher leakage for reducing distortions.
  • Range 100VA TO 100KVA
  • Frequency 50/60/400Hz
  • Primary Voltage up to 1200V
  • Secondary Voltage up to 1200V
  • Di-Electrical at Strength 100V to 3.5 KV ac
View Complete Details

Line Filter

  • Frequency 10 KHz to 10MHz
  • Voltage 1200V
  • Features designed high permeability, suitable air gap in magnetic path to avoid saturation.
  • Range 1A to 100 Amperes single phase and three phase.
  • Di-Electric strength 3.5KV
View Complete Details

Current Auxiliary And Sensing Transformers

  • Frequency 50/60/400Hz.
  • Features Bus bar or single turn or multi turns primary with suitable high grade low loss toroidal cores/E&I lamination, winding is designed for the required current and Knee voltage (saturation of flux and ISF
  • Range 1-10000 Amperes.
  • Burden 0.5VA to 50VA.
  • Di- Electric strength 100V TO 3.5KV.
  • Application Current measurement and current sensing.
View Complete Details

DC Smoothing Filter

  • Features The chokes are designed depending on the current DC and inductance for the energy requirement 0.5 LI Square.
  • Range 0.1 to 5000 joules
  • Current 0.1 to 5000Amperes DC
  • Frequency 100 to 5000Hz Ripple
  • Di- Electric Strength 3.5KV
View Complete Details

Harmonic And Detuned Filter

  • Frequency 50 / 60 Hz
  • Voltage 380 to 480V AC
  • Range KVAR to 500KW
  • No of phase 3 phase
  • Detune factor: 5.6 to 14% of voltage
  • Thermal current 110% of the rated
  • Inductance tolerance +or-3%
  • Operating ambient -20 to +50C
View Complete Details

Power Supply Transformer

  • Phase Singe Phase, Three Phase
  • Features currents result in low power factor & lot of harmonics, require additional consideration in design.
  • Range 1 VA to 250 KVA
  • Frequency 20 to 500, 000 Hz
  • Enclosure Generally open type IP00 dry type
View Complete Details

Constant Voltage Transformer

  • Frequency 50/60/400Hz
  • Phase F Single Phase, 3 Phase
  • Enclosure Open type IP00 or with enclosure
  • Secondary Voltage 1V to 1200V
  • Features Low losses with higher saturation flux suitable shunt adjustments in design and practice gives the required constant voltage output at designated tap.
  • Range 100 VA to 5KVA dry type
  • Terminals Flying Leads or Barrier type shrouded studded lugs
  • Primary Voltage 50 to 1200V
View Complete Details

High Frequency Transformer

  • Frequency 5Kilo cycles to 500Kilo cycles.
  • Features To reduce the high frequency losses (Eddy current) core material used very thin amorphous, Nano crystalline and ferrite cores, To reduce the leakage suitable winding techniques are used.
  • Range 1VA TO 50KVA
  • Voltages Primary up to 1200V To Secondary 1200V
  • Di-Electric Strength 100V to 3.5KV AC.
  • Application DC To DC converters (Buck Boost and SMPS Transformers)
View Complete Details

Isolation Transformer

  • Phase F Single Phase, 3 Phase
  • Range 1 VA to 500 KVA dry type
  • Frequency 20 HZ to 1000 Hz
  • Primary Voltage 1200V
  • Secondary Voltage 1V to 30 KV
  • Di-Electrical at Strength 100V to 30 KV ac
View Complete Details

Reactors Chokes And Coils

  • Features Heat dissipation to reduce the temperature rise, Improves True power factor, reducing harmonic enhances the load motor life as the result of less loss.
  • Range 1 to 1000KVR
  • Working Voltage up to 1200V
  • Current rating 1 to 3000A
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us