Our Products
Our offered Product range includes Battery Capacity Tester, Battery Tester, Coating Rectifier, Battery Life Cycle Tester and Battery Discharge Tester.
Salient Features
ELIND High Rate Discharge Testers are designed to testcrankingperformance of Automotive (SLI) Batteries as per various National and International specifications. The unit comprises of Electronic Active Load to discharge Battery at high current. (Normally at 3*C20 or 5* C20) keeping the current constant through out the test. The test is terminated automatically when the Battery reaches the preset End Voltage.Micro processor based digital timer with non volatile memory records the discharge time precisely up to 0.01 seconds. The unit is rated for short duty of Max. up to 10 minutes. However it can be usedfor continuous discharge at lower currents (30% of its max. capacity) to test Capacity of Battery at C1, C3, or C5 ratings.
PRODUCTION LINE TESTER:
ELIND Production Line Tester is used for routine Pre dispatch testing of batteries to ensure that the battery is free from manufacturing defects like poor inter cell joints, missing separators, lead tree shorting etc. This checks the performance of battery under high discharge current. The test takes only 5 seconds and is recommended on 100% batteries to avoid faulty batteries leaving the manufacturing unit.
| MODEL No. | HRD 12/300 | HRD 12/600 | HRD 12/1000 | HRD 12/1500 | HRD 12/3000 |
| Battery volts | 6/12 V | 6/12 V | 6/12 V | 6/12 V | 6/12 V |
| Discharge current | 300 A | 600 A | 1000 A | 1500 A | 3000 A |
Elind Battery Universal Testeras the name suggests, is a versatile multi testing station designed to test all types of lead acid as well as Ni-cd Batteries as per various National and International specifications. The unit can be used for conducting any of the following tests.
The unit comprises of electronically controlled constant current / constant voltage Battery charger and constant current discharger, along with Micro controller based programmer with LCD display to set Charge / Discharge / Pause program sequence, Charge / Discharge current and Step termination parameters like time, voltage, Ampere hours and number of cycles etc.
Built in data logger sends test data to a printer or to a personal computer at set time interval. Test data can be printed on a 80 column serial printer or recorded / displayed on personal computer through user end PC software. Stored data can be used to draw graphs of voltage / Current / AH / Temperature / Time as per requirement.
SPECIFICATIONS:
INPUT : 1 Phase AC 200-240 volts / 3 Phase 380-440 volts, 50Hz.
CONTROL : Charging-Constant Current / Constant voltage + 1%Discharging constant current + 1%
CH / DCH Time : 1 Second to 100 Hours (99 Hrs 59 Min 59 Sec).
NO. OF STEPS / CYCLE : 8 Steps of Charge, Discharge Or Pause.
STEP TERMINATING PARAMETER : Time / Voltage / Ampere Hours.
CYCLES : 1-9999 Cycles.
INDICATIONS : Digital Voltmeter & Ammeter Charge / Discharge / Pause and Cycle complete.
PRINT INTERVAL : 1sec to Hours.
DATA ACQUISITION : Battery / Cell voltage, Charge / Discharge Current, Amp-Hours, Water bath / electrolyte Temperature, Real time, Date, Mode, (Ch / Dch / Pause).
PROTECTION : Against overload, Short ckt., Rev. polarity.