CHANNEL CONTROLLER

  • Settablc through Software
    • Parameter of Measuremen
    • Maximum Range
    • Unit of Measurement
    • Alarm Level
  • Self Diagnostic Functional Test
  • Accepts 4-20 rnA signal
  • Provides 24 Volts DC to Power Remote Transmitter
  • Serial Communication Output RS 232 / 485
  • Expandable to Two Parameters

It is designed to serve as a host control system for remotely mounted Gas or other Process Transmitters. It is loaded with .software operated exclusive features, Parameters, Maximum Range, unit of measurement & alarm level are all settable in the field to enhance its universal utility & application.

The Model PIC 6002 is a micro controller based Intelligent Indicator controller accepts 4 20 mA input from remotely located transmitter as well as provides 24 volts DC to power the same. It utilizes a point-to-point wiring architecture whereby each Transmitter / Detector Hez id, Alarm/ shutdown device or remote system is individually wired to the control unit. This is the best choice for: >mall systems, where the sensors are located in relative close proximity to the control unit.

Input 4-20 mAcurrent Loops
Displays Alphanumeric8X2
Indications LED Poweron, Test, High Alarm
Output 24 Volts DC to power transmitter
Alarm Adjustable over Full Range
Power Input 100-300 VAC47-60Hz Standard/24VDCOptional
Power Consumption <5 watts
Output Serial Rs-485/ 232 Discrete relaysforfault,lowand high alarm.
Electrical Classifications NEMA1 panel mount
Operating Temperature -10째Cto55째C
Humidity Range 0 to 95% RH, non-condensing
Dimension 96X96X160
Panel Cutout 89X89
Warranty One year
Field Settable (i) Parameter (All Gases, for special consult Endee) (ii) Maximum Range (iii)Unitof Measurement PPM, LEL, Percent (iv) Alarm Level
View Complete Details

Turbine Generators

The Model 7001 is a Rugged, Portable, Easy-to-use Gas Analyser that monitors purge gases and the cooling gas in hydrogen-cooled turbine generators. It measures hydrogen in air & hydrogen in C02 as well as C02 in air during maintenance purging of hydrogen rooted turbine generators. Switch selectable ranges on the instrument make it easytochoosethe measurement required.
View Complete Details

Gas Monitoring System

No Scope for user error These Compact, self contained and intrinsically safe designed instrument housed in a weather proof high impact plastic case are powered with a replaceable 4X1.2V Dc battery. On switching 'ON', the instrument goes thorough its complete self integrity check, and displays factory set Warn and Alarm values before indicating 'Ready' for monitoring While in Operation, the instrument monitors the work place continuously giving the latest update concentration of designated Gas through diffusion sampling. Suction sampling is possible with an optional manual or battery operated pump and adaptor. The poison resistant Pellister or long life, integrally mounted electrochemical Sensors with inbuilt cross interference filters are gas specific. Optionally the sensors can be mounted on an extension cable for monitoring inaccessible locations before entry. The instruments emits an audible beep every 15 sees that provides confidence to the user that he is well protected. Audio, Visual also Warn and Alarms protect him from hazardous situations.
View Complete Details

Flame Sensors

The out put contacts can be used for alarm, annunciation or trip purposes. The front panel has indications for SUPPLY ON. This will turn ON when the supply is given. RELAY ON indicator confairms presence of UV radiation flame. Model UV - FR - 21, has a site adjustable time delay of 2 - 8 seconds and is useful for installations with high flicker situation. UV Flame Amplifiers Relay has been designed to work with Endee make UV Sensor UV - 01. However, it work satisfactorily with UV Sensors rated 220 V AC.rms of various other makes.
View Complete Details

FILED MOUNTED SAMPLING SYSTEMS

  • Custom designed sample conditioning system
  • Application specific principle of Analysis
  • Infrared & Electrochemical detector for CO and
  • C02 & NOx, HC.
  • Electrochemical/paramagnetic or zirconia detector for 0
  • Hydrocarbons & Hydrogen
  • Heated stack mounted filter optional
  • Automatic calibration
  • Built in printer. (Optional)
  • Multipoint sampling system. (Optional)
  • RS-232/485 output for data. logging and further analysis.(Optional)

The Model CA 2000 Series Multi Gas Analyser Is Suitable For The Continuous Measurement Of The Concentrations Of Gases Such As CO, C02, S02, NO, 02, CH4, H2. Maximum Four Of These Components Can Be Measured In The Analyser The Simplicity Of Operation Makes Endee Gas Analyser A Valuable Aid For Continuous Use In Various Applications Changing The Measuring Parameters.

It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific of Gases to Be Measured. Needs of Customer in Selection Optionally Lndee Ca 2000 Is Available With Highly Up-Gradable Microprocessor Based Llectronics Which Is Lquipped Willi Ballery Backup For Ram To Retain The Existing SeL Modes In Case Of Power Failure. Any Unacceptable Deviation From The Standard Stored Values Is Displayed As An Indication "Fault",

Measuring Gas & Range: Gas Ranges & Application dependent.
Display Digital Standard LED optional alphanumeric display
Power Supply 100-290VAC/47-63HZ
Ambient Temp 0-50째 C
Enclosure Aluminium casing (power coated) for indoor application
Mounting Standard: 19" Rackmounted
Optional Flush on Panel/Tabletop
Warm uptime: Analysis Detectordependent
Output(Optional) 4-20mA
Alarms Two Level (selectable range)
Sample Gas condition Temp:0-50째C, Pressure: Lessthan 1.5Kg/cm, The gas should be dry& clean. Other than this suitable sample, Conditioning system isrequired.
Calibration Manual, On command in microprocessor based system.
View Complete Details

UV BURNER CONTROL

Endee UV Flame Sensor uses very sensitive electronic UV tube. The specially tuned UV tube is designed to detect UV radiations emitted by the naked flame. The UV Flame Sensor is insensitive to normal light and refractory glow in furnace walls.

  • UV Sensor is ideally suited for detecting all types of flame, namely flames due to Gas / Coal / Oil fired burners in Boiler and Furnaces.
  • UV Sensor ( Model UV - 01 -AJ) has been specially designed for harsh industrial environment. It provides for easy cleaning of the UV Sensor and viewing of the flame.
  • UV Flame sensor is housed in a metal jacket to provide mechanical protection and various mounting features
  • UV Flame Amplifier / Relay (Model UV - FR - 01) is used in conjunction with UV Flame Sensor to detect various types of flames namely gas, oil, coal etc
  • The UV Flame Amplifier is essentially a stand alone unit, which has Two Potential Free relay contact outputs rated at 220 V AC, 4 Amps.
  • The out put contacts can be used for alarm, annunciation or trip purposes. The front panel has indications for SUPPLY ON. This will turn ON when the supply is given. RELAY ON indicator confairms presence of UV radiation / flame. Model UV - FR - 21, has a site adjustable time delay of 2 - 8 seconds and is useful for installations with high flicker situation.

    UV Flame Amplifiers / Relay has been designed to work with Endee make UV Sensor UV - 01. However, it work satisfactorily with UV Sensors rated 220 V AC.rms of various other makes.

Temperature Range -40 TO +125 Deg. C
Response Time Less than 1 Second
Relay Unit 220VAC, 50HZ4AMP
Enclosure IP40
View Complete Details

FILED-MOUNTED-SAMPLING-SYSTEMS

The Model CA 2000 Series Multi Gas Analyser Is Suitable For The Continuous Measurement Of The Concentrations Of Gases Such As CO, C02, S02, NO, 02, CH4, H2. Maximum Four Of These Components Can Be Measured In The Analyser The Simplicity Of Operation Makes Endee Gas Analyser A Valuable Aid For Continuous Use In Various Applications Changing The Measuring Parameters.

It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific of Gases to Be Measured. Needs of Customer in Selection Optionally Lndee Ca 2000 Is Available With Highly Up-Gradable Microprocessor Based Llectronics Which Is Lquipped Willi Ballery Backup For Ram To Retain The Existing SeL Modes In Case Of Power Failure. Any Unacceptable Deviation From The Standard Stored Values Is Displayed As An Indication "Fault",

  • Custom designed sample conditioning system
  • Application specific principle of Analysis
  • Infrared & Electrochemical detector for CO and
  • C02 & NOx, HC.
  • Electrochemical/paramagnetic or zirconia detector for 0
  • Hydrocarbons & Hydrogen
  • Heated stack mounted filter optional
  • Automatic calibration
  • Built in printer. (Optional)
  • Multipoint sampling system. (Optional)
  • RS-232/485 output for data. logging and further analysis.(Optional)

Measuring Gas & Range: Gas Ranges & Application dependent.
Display Digital Standard LED optional alphanumeric display
Power Supply 100-290VAC/47-63HZ
Ambient Temp 0-50째 C
Enclosure Aluminium casing (power coated) for indoor application
Mounting Standard: 19" Rackmounted
Optional Flush on Panel/Tabletop
Warm uptime: Analysis Detectordependent
Output(Optional) 4-20mA
Alarms Two Level (selectable range)
Sample Gas condition Temp:0-50째C, Pressure: Lessthan 1.5Kg/cm, The gas should be dry& clean. Other than this suitable sample, Conditioning system isrequired.
Calibration Manual, On command in microprocessor based system.
View Complete Details

UV IR TEST LAMP

  • Turn the test lamp toward a flame detector.
  • Press operation switch('ON')
  • Blinks repeatedly after 30 seconds, 10 seconds is not flashing
  • Direct the brightest part of light toward detecting part.
  • wait for flame detector operation.
  • Typically, a flame detector LED is turned on continously after blinking when they are detecting.
  • If a flame detector does not work properly, repeat above 1-4 process with closer access to a flame detector.
  • Press operation switch('OFF')
  • Cover range and test time depend on makers of detectors. Usually 5 sec. waiting time within 2M.
  • Charge after using.
  • Factors that affect the distance used

    Maker of flame detector & window contaminationPower charging status of test lamp in use.For usage from far distance, turn the test lamp toward the center of a detector.Cleanness of front window of test lamp(Keep it clean all the time)

Cover range 3M(max. 5M)
Applied detector UV/IR flame detector (Contact Rezontech, for details.)
Continuous operation time max. 2hours
Weight about 3.2KG
Dimension 145mm X 250mm
Enclosure Aluminium(Anodizing Process)
Charging method 1. Connect charging terminal in body to charger 
2. Connect AC 220V plug of a charger to a receptacle.
3. In complete discharge, max. 17 hours charging is needed.
※ Charge enough after using.(min. 5 hours)



View Complete Details

SAMPLE-CONDITIONING-SYSTEM

  • Custom designed sample conditioning system
  • Application specific principle of Analysis
  • Infrared & Electrochemical detector for CO and
  • C02 & NOx, HC.
  • Electrochemical/paramagnetic or zirconia detector for 0
  • Hydrocarbons & Hydrogen
  • Heated stack mounted filter optional
  • Automatic calibration
  • Built in printer. (Optional)
  • Multipoint sampling system. (Optional)
  • RS-232/485 output for data. logging and further analysis.(Optional)

Measuring Gas & Range: Gas Ranges & Application dependent.
Display Digital Standard LED optional alphanumeric display
Power Supply 100-290VAC/47-63HZ
Ambient Temp 0-50째 C
Enclosure Aluminium casing (power coated) for indoor application
Mounting Standard: 19" Rackmounted
Optional Flush on Panel/Tabletop
Warm uptime: Analysis Detectordependent
Output(Optional) 4-20mA
Alarms Two Level (selectable range)
Sample Gas condition Temp:0-50째C, Pressure: Lessthan 1.5Kg/cm, The gas should be dry& clean. Other than this suitable sample, Conditioning system isrequired.
Calibration Manual, On command in microprocessor based system.
View Complete Details

UV-BURNER-CONTROL

The out put contacts can be used for alarm, annunciation or trip purposes. The front panel has indications for SUPPLY ON. This will turn ON when the supply is given. RELAY ON indicator confairms presence of UV radiation / flame. Model UV - FR - 21, has a site adjustable time delay of 2 - 8 seconds and is useful for installations with high flicker situation.

UV Flame Amplifiers / Relay has been designed to work with Endee make UV Sensor UV - 01. However, it work satisfactorily with UV Sensors rated 220 V AC.rms of various other makes.

Endee UV Flame Sensor uses very sensitive electronic UV tube. The specially tuned UV tube is designed to detect UV radiations emitted by the naked flame. The UV Flame Sensor is insensitive to normal light and refractory glow in furnace walls.

  • UV Sensor is ideally suited for detecting all types of flame, namely flames due to Gas / Coal / Oil fired burners in Boiler and Furnaces.
  • UV Sensor ( Model UV - 01 -AJ) has been specially designed for harsh industrial environment. It provides for easy cleaning of the UV Sensor and viewing of the flame.
  • UV Flame sensor is housed in a metal jacket to provide mechanical protection and various mounting features
  • UV Flame Amplifier / Relay (Model UV - FR - 01) is used in conjunction with UV Flame Sensor to detect various types of flames namely gas, oil, coal etc
  • The UV Flame Amplifier is essentially a stand alone unit, which has Two Potential Free relay contact outputs rated at 220 V AC, 4 Amps.

Temperature Range -40 TO +125 Deg. C
Response Time Less than 1 Second
Relay Unit 220VAC, 50HZ4AMP
Enclosure IP40
View Complete Details

UV-IR-test-Lamp

Factors that affect the distance used

Maker of flame detector & window contaminationPower charging status of test lamp in use.For usage from far distance, turn the test lamp toward the center of a detector.Cleanness of front window of test lamp(Keep it clean all the time)

  • Turn the test lamp toward a flame detector.
  • Press operation switch('ON')
  • Blinks repeatedly after 30 seconds, 10 seconds is not flashing
  • Direct the brightest part of light toward detecting part.
  • wait for flame detector operation.
  • Typically, a flame detector LED is turned on continously after blinking when they are detecting.
  • If a flame detector does not work properly, repeat above 1-4 process with closer access to a flame detector.
  • Press operation switch('OFF')
  • Cover range and test time depend on makers of detectors. Usually 5 sec. waiting time within 2M.
  • Charge after using.

Cover range 3M(max. 5M)
Applied detector UV/IR flame detector (Contact Rezontech, for details.)
Continuous operation time max. 2hours
Weight about 3.2KG
Dimension 145mm X 250mm
Enclosure Aluminium(Anodizing Process)
Charging method 1. Connect charging terminal in body to charger 
2. Connect AC 220V plug of a charger to a receptacle.
3. In complete discharge, max. 17 hours charging is needed.
※ Charge enough after using.(min. 5 hours)



View Complete Details

Moisture Sensor

The MOISTURE SENSOR is of solid Polymer structure and is, Fast, Accurate and Reliable Water in Oil and Temperature Transducers designed for Industrial, Transformers and Locomotive applications where a reliable and accurate measurement of water in oil content is highly required. Its fast response time combined with Reliable and Rugged structure make it even suitable for fixed in situ mounting in fluids under Pressure

Dissolved water in oil is a critical data for Oil System Management as water consumes oil additives that can result in severe mechanical damages due to degradation of Lubricant Properties.

In a comprehensive Transformer Maintenance Program, determination of the Moisture content and Temperature of the oils is an essential part. Excessive moisture contents causes accelerated ageing of the Insulation Materials and reduce their Dielectric strength. In extreme cases this can result in Arcing and Short Circuits within the windings. Accurate moisture analysis can also warn about Leaks in the Oil System as water is absorbed from the surrounding air.

AMM-160 is a Portable Moisture & Temperature in oil meter or a sensor that provides an excellent reliable, economical and Time saving solution for measurement of moisture in Oil in the field.

It measures Moisture-in-oil in terms of the Water Activity (aw) and Temperature. The same gets converted into PPM units as in Transformer applications, PPM-unit is traditionally used.

Humidity 0 to 100%RH, non-condensing
Temperature range -10 to 50°C
Display BACKLIT LCD
Power supply 6 VOLTS, DC 4NOS Rechargeable batteries
COMPUTER INTERFACE RS232
DATA LOGGER 32 kb
Storage temperature -40 to 70°C
MOISTURE-IN-OIL PROBE:  
Water activity 0 - 1
Relative Saturation (RS) 0 to 100%
Accuracy 0.025
Temperature. -40 to 100 °C
PPM of water 0-1000ppm typical
Water Sensor Thin Film Polymer
Temperature Sensor RTD 100
Sensor protection grid Aluminium Alloy
Pressure range of sensor 1 - 5 bar
Probe material Stainless steel
Probe cable length 2 meters Standard
Probe Length Extension Upto 10 Meters Opts
View Complete Details

HYGROMETER-PORTABLE

ENDEE Model HTM 06 is a unique minituarised portable RH & Temp. meter accurate enough for use in the laboratory as a reference reading. Advanced digital technology Provides all inclusive accuracy specification & reliability that require no field calibration Its well proven capacitive CMOS IC sensor technology offer exceptional resistance to comman contaminants like organic solvents.

Simple to operate, this self contained relative Humidity meter is convenient, easy to use & dependable. It is accurate enough for use as a reference reading in the laboratory.

  • Spot Checking Humidity & Temp
  • Quick Adjustment of Air conditioning & Heating Systems.
  • Checking Performance of Dryers.
  • Fully Interchangeable Sensor
  • Battery Powered Digital Readout.
  • 0-100 % RH Range & - 40 C to +125 C Temp.
  • Long Life CMOS IC Sensor.
  • Maintenance Free Washable Sensor.
  • Low Battery Indication.
  • No Field calibration Required.
  • Recall Feature.

Overall Ranges 0 - 100 % RH
Sampling Method Diffusion (D) orSuction (S)
Temp. -20 to +125 deg.C
Minimum Resolution 0.1 % & 0.1 Deg.C
Indication Four digit LCD Display
Sensor Digital Capacitive Sensor & platinum thermo-resistance
Sensor Protection Sintered Filter
Calibration No calibration ever needed
Accuracy +/- 2% with Saturated Salt Calibration & +/-0.2 Deg.C
Operating Temp. 20 to 125 deg. C
Storage Temp. -20 to + 60 deg. C
Measuring Rate 2.5 Per second
Repeatabelity +/- 0.1% RH & deg.C
Hystersis +/- 1 % RH
Over range alarm Automatic
Power One 9V battery
Housing High Impact Plastic Housing
Dimensions 150 X 80 X 30 mm
Slandered Accessories Leather Case With Belt Loop & Battery
Optional Accessories RS 232 COMMUNICATION INTERFACE 
DATA LOGGER WITH DATE & TIME

View Complete Details

Leak Detectors EZ-Sense

  • Model Number EZ-Sense -1 with Indication, EZ-Sense - B Non Indicative
  • Resolution lPPMorl%LEL
  • Response Time 2-3 seconds
  • Warranty One year
  • Battery High Impact Plastic. (ABS)
  • Temperature -10°C to 50°C
  • Weight 200 GM
  • Dimension 119(H) X80(L)X 25(D)
  • Gas Detected LNG, LPG, CH4 Flammable gas, H2
  • Leak Strength Indication 1 - DIGITAL B - Three Level Visual Alarms
  • Calibration PPMorLEL% (To Customers specs)
  • Sensor Solid state semiconductor
  • Housing High Impact ABS Plastic
  • Alarm indication Alarm indication
  • Calibration Not required
  • Gooseneck 6 volt alkaline, Rechargeable batteries 1.5V (AA Alkaline)
  • Warm-uptime About 10 sec
  • Battery Operating Time About 4 hours
  • Humidity 15 to 95% RH

This light, Hand-held combustible gas leak detector is the perfect tool locating leaks of combustible »gases such as Compressed Natural Gas (CNG), Liqufied Petroleum Gas (LPG) Liqufied 1 Natural Gas (LNG), Methane (Ch4), Hydrogen (H2).

  • Indicating or Non-Indicating Leak Alarm
  • Suitable for CNG / LPG Leaks.
  • Indicates the Intensity of Leak
  • Calibrated in PPM or Explosive Limit Range
  • Simple to Operate
  • Highly Sensitive Detection Circuitry
  • Polyn Size Light Weight Design
  • Audible Alarm / Low Battery Warning Buzzer
  • Tough Abs Plastic Housing
  • No Scope for user error These Compact, self contained and intrinsically safe designed instrument housed in a weather proof high impact plastic case are powered with a replaceable 4X1.2V Dc battery. On switching 'ON', the instrument goes thorough its complete self integrity check, and displays factory set Warn and Alarm values before indicating 'Ready' for monitoring While in Operation, the instrument monitors the work place continuously giving the latest update concentration of designated Gas through diffusion sampling.

    Suction sampling is possible with an optional manual or battery operated pump and adaptor. The poison resistant Pellister or long life, integrally mounted electrochemical Sensors with inbuilt cross interference filters are gas specific. Optionally the sensors can be mounted on an extension cable for monitoring inaccessible locations before entry. The instruments emits an audible beep every 15 sees that provides confidence to the user that he is well protected. Audio, Visual also Warn and Alarms protect him from hazardous situations.

View Complete Details

Dust Guard

  • Field Proven Tribo Electric Technology ensures reliability
  • Direct sensing method; Actual particulate measurement
  • Adaptable suitable for virually all dust collectors
  • Damping systems for false alarms
  • Adjustable Sensitivity, Alarm Level and time delay to suit wide variety of powders and bulk solids
  • Robust & reliable
  • Easy installation, Low maintenance
  • Wide range of duct size from 250mm to 2m
  • Integral Assembly of sensor and electronics in rugged housing

Stack Gaurd Finds applications in wide variety of industries where Detection and control of dust level is critical for the safety, Maintenance , Equipment operation, Plant Efficiency and or the environment.

It provides Reliable and Economical Detection of leak and filter Failures in Powder and Bulk Solids industries Stack guard has LED visual Indication and relay output to maximize its user-friendliness and automation capabilities.

It incorporates a specially designed adjustable damping system that increases its response time and prevents False alarms

Enclosure Aluminum Casting , Weatherproof to IP66
Ambient Temperature -20 Deg.C to +70 Deg.C
Flue Gas Temperature 0-200 Deg. C.,700 Deg.c Optional
Operating Range 0.1 to 1000mg/m3
Duct Diameter 250mm to 2m
Stack connection Quick Disconnect Fitting clamp
Analogue Output 4-20mA isolated( Liner)
Alarm Output 2 SPDT Relay Output
Alarm Level Adjustable
Damping adjustable
Power Requirement 115 V/220 V Ac, 24 V DC
Probe Material 316 stainless steel
View Complete Details

DUST-GUARD

Stack Gaurd Finds applications in wide variety of industries where Detection and control of dust level is critical for the safety, Maintenance , Equipment operation, Plant Efficiency and or the environment.

It provides Reliable and Economical Detection of leak and filter Failures in Powder and Bulk Solids industries Stack guard has LED visual Indication and relay output to maximize its user-friendliness and automation capabilities.

It incorporates a specially designed adjustable damping system that increases its response time and prevents False alarms

  • Field Proven Tribo Electric Technology ensures reliability
  • Direct sensing method; Actual particulate measurement
  • Adaptable suitable for virually all dust collectors
  • Damping systems for false alarms
  • Adjustable Sensitivity, Alarm Level and time delay to suit wide variety of powders and bulk solids
  • Robust & reliable
  • Easy installation, Low maintenance
  • Wide range of duct size from 250mm to 2m
  • Integral Assembly of sensor and electronics in rugged housing

Enclosure Aluminum Casting , Weatherproof to IP66
Ambient Temperature -20 Deg.C to +70 Deg.C
Flue Gas Temperature 0-200 Deg. C.,700 Deg.c Optional
Operating Range 0.1 to 1000mg/m3
Duct Diameter 250mm to 2m
Stack connection Quick Disconnect Fitting clamp
Analogue Output 4-20mA isolated( Liner)
Alarm Output 2 SPDT Relay Output
Alarm Level Adjustable
Damping adjustable
Power Requirement 115 V/220 V Ac, 24 V DC
Probe Material 316 stainless steel
View Complete Details

DYNOPTICS

Stack Gaurd Finds applications in wide variety of industries where Detection and control of dust level is critical for the safety, Maintenance , Equipment operation, Plant Efficiency and or the environment.

It provides Reliable and Economical Detection of leak and filter Failures in Powder and Bulk Solids industries Stack guard has LED visual Indication and relay output to maximize its user-friendliness and automation capabilities.

It incorporates a specially designed adjustable damping system that increases its response time and prevents False alarms

  • Field Proven Tribo Electric Technology ensures reliability
  • Direct sensing method; Actual particulate measurement
  • Adaptable suitable for virually all dust collectors
  • Damping systems for false alarms
  • Adjustable Sensitivity, Alarm Level and time delay to suit wide variety of powders and bulk solids
  • Robust & reliable
  • Easy installation, Low maintenance
  • Wide range of duct size from 250mm to 2m
  • Integral Assembly of sensor and electronics in rugged housing

Enclosure Aluminum Casting , Weatherproof to IP66
Ambient Temperature -20 Deg.C to +70 Deg.C
Flue Gas Temperature 0-200 Deg. C.,700 Deg.c Optional
Operating Range 0.1 to 1000mg/m3
Duct Diameter 250mm to 2m
Stack connection Quick Disconnect Fitting clamp
Analogue Output 4-20mA isolated( Liner)
Alarm Output 2 SPDT Relay Output
Alarm Level Adjustable
Damping adjustable
Power Requirement 115 V/220 V Ac, 24 V DC
Probe Material 316 stainless steel
View Complete Details

CALIBRATION CYLINDER

  • The user has 10 litres of usable gas.
  • The cans are light weight and can easily be carried into difficult locations to check the instruments.
  • No wastage of gas as the gas is drawby a re-usable "take-off value with flow indicator".
  • The mixtures are high accuracy and each batch is checked prior to despatch.
  • Special mixtures to customer specification can be supplied subjecttoa minimum quantity of Mini Spancanspermixture.
  • Many mixtures available ex-stock.
  • Express shipment by courier to most areas of India.
  • Disposal, non-returnable containers reduce overhead costs.

Calibration-Cylinders Finds applications in wide variety of industries where Detection and control of dust level is critical for the safety, Maintenance , Equipment operation, Plant Efficiency and or the environment.

It provides Reliable and Economical Detection of leak and filter Failures in Powder and Bulk Solids industries Stack guard has LED visual Indication and relay output to maximize its user-friendliness and automation capabilities.

It incorporates a specially designed adjustable damping system that increases its response time and prevents False alarms

Water Capacity 0.5Ltr
Fill Pressure/Burst Pressure 21 bar/55 bar
Quantity of Gas available for use 10Ltrand20Ltr
Container wall material Aluminium
Weight when full-* Less than 300 gms.
View Complete Details

CALIBRATION AMPOULES

  • Using these gases it may be possible to cross-calibrate sensors for other gases and using a beakers of different volumes rating. It is possible of to Calibration at different ranges than the concentration mentioned on the Ampule.
  • Before use, it is important that both the ampoules and the calibration beaker are clean and dry. Ampoules should not be used if the glass is cracked or fractured and the calibration beaker should not be used unless the lid is tight fitting.
  • Because some gases (e.g. Cl2) are easily absorbed it is recommended that the internal surfaces of the calibration beaker Be permeated with the calibration gas prior to actual calibration.
  • This is most easily accomplished by placing an ampoule in the beaker, placing the beaker over the sensor and breaking the ampoule as if performing a normal calibration routine. The ampoule should be left in place for approximately 5 minutes.

Calibration-Ampoules Finds applications in wide variety of industries where Detection and control of dust level is critical for the safety, Maintenance , Equipment operation, Plant Efficiency and or the environment.

It provides Reliable and Economical Detection of leak and filter Failures in Powder and Bulk Solids industries Stack guard has LED visual Indication and relay output to maximize its user-friendliness and automation capabilities.

It incorporates a specially designed adjustable damping system that increases its response time and prevents False alarms

Water Capacity 0.5Ltr
Fill Pressure/Burst Pressure 21 bar/55 bar
Quantity of Gas available for use 10Ltrand20Ltr
Container wall material Aluminium
Weight when full-* Less than 300 gms.
View Complete Details

CALIBRATION-CYLINDERS

Calibration-Cylinders Finds applications in wide variety of industries where Detection and control of dust level is critical for the safety, Maintenance , Equipment operation, Plant Efficiency and or the environment.

It provides Reliable and Economical Detection of leak and filter Failures in Powder and Bulk Solids industries Stack guard has LED visual Indication and relay output to maximize its user-friendliness and automation capabilities.

It incorporates a specially designed adjustable damping system that increases its response time and prevents False alarms

  • The user has 10 litres of usable gas.
  • The cans are light weight and can easily be carried into difficult locations to check the instruments.
  • No wastage of gas as the gas is drawby a re-usable "take-off value with flow indicator".
  • The mixtures are high accuracy and each batch is checked prior to despatch.
  • Special mixtures to customer specification can be supplied subjecttoa minimum quantity of Mini Spancanspermixture.
  • Many mixtures available ex-stock.
  • Express shipment by courier to most areas of India.
  • Disposal, non-returnable containers reduce overhead costs.

Water Capacity 0.5Ltr
Fill Pressure/Burst Pressure 21 bar/55 bar
Quantity of Gas available for use 10Ltrand20Ltr
Container wall material Aluminium
Weight when full-* Less than 300 gms.
View Complete Details

CALIBRATION-AMPOULES

Calibration-Ampoules Finds applications in wide variety of industries where Detection and control of dust level is critical for the safety, Maintenance , Equipment operation, Plant Efficiency and or the environment.

It provides Reliable and Economical Detection of leak and filter Failures in Powder and Bulk Solids industries Stack guard has LED visual Indication and relay output to maximize its user-friendliness and automation capabilities.

It incorporates a specially designed adjustable damping system that increases its response time and prevents False alarms

  • Using these gases it may be possible to cross-calibrate sensors for other gases and using a beakers of different volumes rating. It is possible of to Calibration at different ranges than the concentration mentioned on the Ampule.
  • Before use, it is important that both the ampoules and the calibration beaker are clean and dry. Ampoules should not be used if the glass is cracked or fractured and the calibration beaker should not be used unless the lid is tight fitting.
  • Because some gases (e.g. Cl2) are easily absorbed it is recommended that the internal surfaces of the calibration beaker Be permeated with the calibration gas prior to actual calibration.
  • This is most easily accomplished by placing an ampoule in the beaker, placing the beaker over the sensor and breaking the ampoule as if performing a normal calibration routine. The ampoule should be left in place for approximately 5 minutes.

Water Capacity 0.5Ltr
Fill Pressure/Burst Pressure 21 bar/55 bar
Quantity of Gas available for use 10Ltrand20Ltr
Container wall material Aluminium
Weight when full-* Less than 300 gms.
View Complete Details

Wireless Systems

We are offering wireless systems.

hnls-2002 is self contained and battery operated. The sensor functions by transmission of radio wave messages to the interface relayer, wireless monitor or gateway bridges or any other compatible receiving controller. The device is field adjustable for interface with other systems. Features such as the relay alarm tests and battery voltage indication make this device a truly remarkable gas detection system.

View Complete Details

Calibration Cylinders

We are offering calibration cylinders.

calibration-cylinders finds applications in wide variety of industries where detection and control of dust level is critical for the safety, maintenance , equipment operation, plant efficiency and or the environment. It provides reliable and economical detection of leak and filter failures in powder and bulk solids industries stack guard has led visual indication and relay output to maximize its user-friendliness and automation capabilities. It incorporates a specially designed adjustable damping system that increases its response time and prevents false alarms

View Complete Details

Portable Hygrometer

We are offering portable hygrometer .

endee model htm 06 is a unique minituarised portable rh & temp. Meter accurate enough for use in the laboratory as a reference reading. Advanced digital technology provides all inclusive accuracy specification & reliability that require no field calibration its well proven capacitive cmos ic sensor technology offer exceptional resistance to comman contaminants like organic solvents.

View Complete Details

Fixed Gas Monitors Weather Proof

Fixed gas monitors 1565 (weather proof) download modular constructionsingle multipoint monitoringtoxic, explosive gas, vapour, smokemonitoring systemthree level concentration and fault alarmpower on ledvisual and audible alarm facilityremote alarm capabilityreliable solid state circuitrymaintenance free fail safe operationlong life solid state catalytic sensortest points for alarm settingsoptional analogue or digital meterweather proof or ex proof detectors.
View Complete Details

Fixed Gas Monitors Flame Proof

Relay contacts could be typically used to actuate remote alarms, increase ventilation, shut off gas supply, or shut down a process. Should it not be feasible to install the sensor at the desired location because of maintenance, or operational consideration, a suction based sampling system can be employed. The sensors detectors are of very sturdy construction, with weather proof or ex-proof housings and are designed to serve for several years under normal operating conditions.
View Complete Details

Two Channel Indicator Controller

It is designed to serve as a host control system for remotely mounted gas or other process transmitters. It is loaded with .software operated exclusive features, parameters, maximum range, unit of measurement & alarm level are all settable in the field to enhance its universal utility & application. The model pic 6002 is a micro controller based intelligent indicator controller accepts 4 20 ma input from remotely located transmitter as well as provides 24 volts dc to power the same. It utilizes a point-to-point wiring architecture whereby each transmitter detector hez id, alarm shutdown device or remote system is individually wired to the control unit. This is the best choice for: >mall systems, where the sensors are located in relative close proximity to the control unit.
View Complete Details

Multi Channel Gas Controller Controller

Multi channel gas controller controller 8420 download nema 1 rack panel mountmodular plug in design including modular power supply2 to 8 channel 19" rack capacitydiscrete or zoned alarm relays (2 alarms plus fault)status and parameters accessible via rs 485 (optional)compatible with plcs, scada and dcscompatible with all types of transmittersalarm disable alarm silence function.
View Complete Details

Fixed Gas Scanners

Fixed gas scanners sc-5101 download single and up to 16 input modelssingle or multi gas configurationself integrity checksimultaneous display of channel no.concentration & unit of measurementlow & high alarm indication for each channelcommon kelay output for alarm & haltdc output to power transmittersselectable 0.11" resolution16 x 1 alpha numeric display
View Complete Details