Post Buy Requirement
Evana
Mumbai, Maharashtra, India
gstGST : 27ADDPB9762E1ZM Verified Add Review

Electrosurgical Units #4072698

Radio Cautery Machine

  • Min. Order (MOQ) 1
  • Type Cautery Machines
  • Application Hospital
  • Color Grey
  • Feature Durable
  • Voltage 220v
  • Condition New
  • Finishing Polished
  • Power Source Electrical
  • Warranty 1 Yr
  • Color white

400 d is a surgical cautary machine . Both mono polar and bi polar with double food switch and accessorize.

View Complete Details

ITC-300D Digital Innovation Electrosurgical Unit

  • Power Consumption 750VA
  • High Power 300W at 500
  • Operating Frequency 400kHz+10%
  • Power Source 100-250V / 50-60Hz
  • Weight 15kg
  • Dimension (WXDXH) 350X350X130(mm)
  • RF Leakage Current 20mA
  • Modulation Frequency 32kHz+10%

Feature

  • The percentage output digital display shows on the panel.
  • It is controlled by mincroproceeor which is responsible for controlling and monitoring of all the functions and features in unit.
  • Ouput vlues (CUT, COAG, BIPOAR) are remained in the memory after switching offf. These value will be come up to the display at turning other power.
  • Automatic bipolar output without using foot swtich. (400D, 300D)
  • Multi monopolar outlets can be used for two hand control outlets and for one laparoscope outlets.
  • This can be hand or foor operated.
  • A bipolar output power profile that providea good resolution to permit changes in power levels for delicate work, yet has sufficient maximum output power capability to satisfy the requirements of the more demading procedures.
  • Spray coagulation provides the trans urethal resection (TUR) and endoscopic procedures in urology. (300D / 400D)
  • Acessibility to parts and ease of maintenance that is unsurpassed.
  • Versatility, Reliability.
  • Desiggned for safety / Designed for ease of use.

Details


Download Detail File : Click Here
View Complete Details

RF-180 Radio Frequency Electrosurgical Unit

  • Power Consumption 420VA
  • Operarting Frequency 6.2 Mhz+10%
  • Power Source 100-250V / 50-60Hz
  • Protection Class / Type Class1/BF
  • Weight 9kg
  • Dimension (WXDXH) 350X350X130(mm)

What is HF Coagulation?It is a way of coagulation to the 5mm depth of tissue. form a patient plate with a large surface area, a high frequency current is conducted through the patient's body to an active electrode. Once a given minimum value is exceeded, this current density  eads to the heating (joule heat),   which is necessary for coagulation purposes, close to an active electrode.
Therefore the purpose off ccoagulation is completely accom plished in the HF coagulation. the rate of complate recovery is the epoch-marking change over than 95% at a time comparing any electro surgery with cold steel surgery. The reason is that depth of coagulation is decided by the electrode itself being not affected and determined by doctor's skill, beause the device is designed to coagulate to 5mm depth of tissue. That why HF coagulation is a very simple and safe way of coagulation.

Relation Operates

  • Cervical Erosion
  • Laparoscope
  • Bleeding control during C/So
  • Myoma Portionis HF Coagulation
  • condyloma
  • cust tumor liquor
  • conization or LLETZ
  • polyectomy
  • cesarean section etc

Details


Download Detail File : Click Here
View Complete Details

ITC-400D Digital Innovation Electrosurgical Unit

  • Power Consumption 950VA
  • High Power 400W at 500
  • Operating Frequency 400kHz+10%
  • Power Source 100-250V / 50-60Hz
  • Weight 15kg
  • Dimension (WXDXH) 350X350X130(mm)
  • RF Leakage Current 43mA
  • Modulation Frequency 32kHz+10%

Feature

  • The percentage output digital display shows on the panel.
  • It is controlled by mincroproceeor which is responsible for controlling and monitoring of all the functions and features in unit.
  • Ouput vlues (CUT, COAG, BIPOAR) are remained in the memory after switching offf. These value will be come up to the display at turning other power.
  • Automatic bipolar output without using foot swtich. (400D, 300D)
  • Multi monopolar outlets can be used for two hand control outlets and for one laparoscope outlets.
  • This can be hand or foor operated.
  • A bipolar output power profile that providea good resolution to permit changes in power levels for delicate work, yet has sufficient maximum output power capability to satisfy the requirements of the more demading procedures.
  • Spray coagulation provides the trans urethal resection (TUR) and endoscopic procedures in urology. (300D / 400D)
  • Acessibility to parts and ease of maintenance that is unsurpassed.
  • Versatility, Reliability.
  • Desiggned for safety / Designed for ease of use.

Details


Download Detail File : Click Here
View Complete Details

Mini-COG Radio Frequency Electrosurgical Unit

  • Power Consumption 15VA
  • Power Source 100-250V / 50-60Hz
  • Protection Class / Type Class1/B
  • Monopolar 35W (300)
  • Biploar 35w (300)
  • Weight 2.2kg
  • Dimension (WXDXH) 195X165X66(mm)

Advantage

  • Scars
  • Hybrid skin resurfacing
  • Skin rejuvenation
  • Fine wrinkled
  • Enlarged pores
  • Stretch mark
  • Melasma

Details


Download Detail File : Click Here
View Complete Details

ITC-250D Digital Innovation Electrosurgical Unit

  • Power Consumption 750VA
  • High Power 250W at 500
  • Operating Frequency 400kHz+10%
  • Power Source 100-250V / 50-60Hz
  • Weight 15kg
  • Dimension (WXDXH) 350X350X130(mm)
  • Protection Class Type Class1 / CF

Feature

  • The percentage output digital display shows on the panel.
  • It is controlled by mincroproceeor which is responsible for controlling and monitoring of all the functions and features inunit.
  • Input avlues (CUT, COAG, BIPOAR) are remained in the memory after switching offf. These value will be come up to the display at turning other power.
  • Multi monopolar outlets can be used for two hand control outlets and for one laparoscope outlets.
  • This can be hand or foor operated.
  • Versatility, Reliability.
  • Desiggned for safety / Designed for ease of use.
  • Accessibility to parts profile that provides good resolution to permit samll changes in power levels for delicate work, yet has sufficient maximum output power capability to satisfy the requirements of the more demading procedures.
  • Spray coagulation provides the trans urethal resection (TUR) and endoscopic procedures in urology. (300D / 400D)

Details


Download Detail File : Click Here
View Complete Details

RF-70 Radio Frequency Electrosurgical Unit

  • Power Consumption 200VA
  • Operarting Frequency 1.2 Mhz+10%
  • Power Source 100-250V / 50-60Hz
  • Protection Class / Type Class1/B
  • Weight 7kg
  • Dimension (WXDXH) 170X220X110(mm)

Feature

  • RF70 is new general purpose electro surgical equipment suitable to be used for general surgery.
  • High technology, compact solid-state electro surgical unit with bboth monopolar
  • & biploar facility.
  • High effective coagulation without any cutting effect, thus less depth of tissue necrosis and quicker coagulation.

Details


Download Detail File : Click Here
View Complete Details
Tell Us What are you looking for? Will call you back