My ExportersIndia

For Buyer

For Seller

For Help

Our Products

We offer the best product range of Electronic Soft Starter, Heater Controller, Human Body Static Dissipater, DC Panel Meter and Auto Mains Failure Relay.

Heater Controller

  • Phase 1 Phase, 3 Phase
  • Size On request
  • Features & specifications Isolated from high voltage, Internal overheat protection (optional), RC snubbers included for transient voltage protection
  • Aux Supply 230V AC, 50 Hz
  • Control input signals 4-20 mA / 0-10VDC / 0- 5 VDC
  • Control method Burst & phase angle firing modes
View Complete Details

Human Body Static Dissipater

  • Power Supply 230 V AC
  • Max Test Voltage 1.5 V DC
  • Type of Ex protection Ex”d”
  • Type of ingress protection IP66
  • Temperature Class T4/T6
  • Interlock contact 1 C/o potential free contact
  • Display bright 1” red display 4 digits
  • Unit size 355 x 270 x 165 are in mm with Gland
  • Overall size 20.5” L x 14.5”H x 8” D
  • Present resistance value 750K ohm
  • Mounting Wall mounting SS plate
  • Handles Test & Ref. Ground handle
  • Power On/Off switch 06 Amp
View Complete Details

Auto Mains Failure Relay

  • Features Micro controller technology, Withstands a dip to 0V of auxiliary supply for 1 second, Alphanumeric LCD display with keypad for easy of operation, Remote starting and stopping facilities
  • auxiliary supply 7 V to 35Vdc
View Complete Details

Electronic Soft Starter

  • Features Soft Start facility, with initial torque setting by minimum pedestal voltage, ramp time adjustable for setting ramping time, adjustable from 1 to 180 secs
  • Rated Insulation Voltage 600V
  • Rated Operating Voltage 415/440V AC + 10%/ – 15%, 3 phase, 50 Hz
  • Rated control supply voltage 230 V AC + 15%/ – 15%, 1 phase, 50 Hz
  • Recommended load 3 – Phase AC Motor, multiple motors or other loads arenot recommended except under specific circumstances.
  • Overload capacity 115% Continuous, 150% for 10 seconds and 200% for 5 seconds
  • Ambient Temperature During Operation
  • During Storage -40 degC to +70 degC
  • Altitude of Installation 1000 meters (Above 1000m derating had to be done)
  • Degree of protection Main Circuit – IP00, Supply and Control Circuit – IP20
  • Main Circuit Provided with external bypass contactor provision
  • Display LED Seven Segment Display with 4 keys keypad for setting parameters
  • Main Settings Ramp time during start – 1 to 180 sec
  • Ramp time during stop – 1 to 180 sec
  • Pedestal (Initial) voltage – 1 to 60%
  • Current limit – 1.5 to 7 x rated current
  • Signal Relays One C/O relay for bypass contactor
  • Control Circuit Number of digital Inputs – 3 (Start, stop, emergency stop)
  • Protections Internal protection for Overtemperature and transient voltage
  • Voltage rating of thyristors 1400 to 1600 PIV
  • Types of cooling Air-cooled below 250 hp, fan cooled for 250 hp and above.
  • Over temperature protection Normally closed contact output, thermal switch provided for heatsink
  • SCR Protection MOV transient voltage suppressors to absorb high energy voltage transients
View Complete Details

DC PANEL METER

  • Display Type LED Seven Segment, 4 Digit
  • Features True RMS measurement, Man-machine interface through keypad & display, Auto reset or Manual reset during fault, Annunciation indicates the type of fault, Shunt ratio programmable
  • Protection Over Current / Under Current / Over Voltage / Under Voltage / Over and Under Current
  • Size Panel mountable – 96X96X65mm