My ExportersIndia

For Buyer

For Seller

For Help

Our Products

We offer a complete product range of Electronic Soft Starter, Heater Controller, Human Body Static Dissipater, DC Panel Meter and Auto Mains Failure Relay

Heater Controller

  • Phase 1 Phase, 3 Phase
  • Size On request
  • Features & specifications Isolated from high voltage, Internal overheat protection (optional), RC snubbers included for transient voltage protection
  • Aux Supply 230V AC, 50 Hz
  • Control input signals 4-20 mA / 0-10VDC / 0- 5 VDC
  • Control method Burst & phase angle firing modes
View Complete Details

Human Body Static Dissipater

  • Power Supply 230 V AC
  • Max Test Voltage 1.5 V DC
  • Type of Ex protection Ex”d”
  • Type of ingress protection IP66
  • Temperature Class T4/T6
  • Interlock contact 1 C/o potential free contact
  • Display bright 1” red display 4 digits
  • Unit size 355 x 270 x 165 are in mm with Gland
  • Overall size 20.5” L x 14.5”H x 8” D
  • Present resistance value 750K ohm
  • Mounting Wall mounting SS plate
  • Handles Test & Ref. Ground handle
  • Power On/Off switch 06 Amp
View Complete Details

Auto Mains Failure Relay

  • Features Micro controller technology, Withstands a dip to 0V of auxiliary supply for 1 second, Alphanumeric LCD display with keypad for easy of operation, Remote starting and stopping facilities
  • auxiliary supply 7 V to 35Vdc
View Complete Details

Electronic Soft Starter

  • Features Soft Start facility, with initial torque setting by minimum pedestal voltage, ramp time adjustable for setting ramping time, adjustable from 1 to 180 secs
  • Rated Insulation Voltage 600V
  • Rated Operating Voltage 415/440V AC + 10%/ – 15%, 3 phase, 50 Hz
  • Rated control supply voltage 230 V AC + 15%/ – 15%, 1 phase, 50 Hz
  • Recommended load 3 – Phase AC Motor, multiple motors or other loads arenot recommended except under specific circumstances.
  • Overload capacity 115% Continuous, 150% for 10 seconds and 200% for 5 seconds
  • Ambient Temperature During Operation
  • During Storage -40 degC to +70 degC
  • Altitude of Installation 1000 meters (Above 1000m derating had to be done)
  • Degree of protection Main Circuit – IP00, Supply and Control Circuit – IP20
  • Main Circuit Provided with external bypass contactor provision
  • Display LED Seven Segment Display with 4 keys keypad for setting parameters
  • Main Settings Ramp time during start – 1 to 180 sec
  • Ramp time during stop – 1 to 180 sec
  • Pedestal (Initial) voltage – 1 to 60%
  • Current limit – 1.5 to 7 x rated current
  • Signal Relays One C/O relay for bypass contactor
  • Control Circuit Number of digital Inputs – 3 (Start, stop, emergency stop)
  • Protections Internal protection for Overtemperature and transient voltage
  • Voltage rating of thyristors 1400 to 1600 PIV
  • Types of cooling Air-cooled below 250 hp, fan cooled for 250 hp and above.
  • Over temperature protection Normally closed contact output, thermal switch provided for heatsink
  • SCR Protection MOV transient voltage suppressors to absorb high energy voltage transients
View Complete Details

DC PANEL METER

  • Display Type LED Seven Segment, 4 Digit
  • Features True RMS measurement, Man-machine interface through keypad & display, Auto reset or Manual reset during fault, Annunciation indicates the type of fault, Shunt ratio programmable
  • Protection Over Current / Under Current / Over Voltage / Under Voltage / Over and Under Current
  • Size Panel mountable – 96X96X65mm