Post Buy Requirement
EE
Vadodara, Gujarat, India
Add Review

Our Products #4494957

LED Seven Segment Display



  • LED seven segment Display

  • Annunciation indicates the type of fault

  • Providing 2.5, 5 & 10C curve for overload

  • With Extra protection class
    CT (20, 35, 55 mm ID )

  • Modbus RTU protocol RS-485*

  • Reset inhibit Function


View Complete Details

Cyclic Load Energy Saver

  • Features Digital ammeter with auto scanner for three phase currents, Optional features like star-delta timer
  • Supply Voltage Operation 230V ± 10%, 50HZ.
  • Load Sensing Through Current Transformer
  • Protection Over Load, Single Phasing, Unbalance
  • LED Annunciation R, Y, B Phase Current Indication & Delta And Star Mode Indication
  • Delta to Star Changeover Time I-60 sec. settable
  • Start to Delta Change over Time Instantaneous
  • Bypass Automatic Delta to Star Conversion Bypass Through Toggle Switch (except protection)

SCOPE FOR SAVING

Following table shows the scope for saving energy for the motors of different capacity ranges at different loads. The actual values will vary for different ratings of motor and the savings can be higher or lower depending upon electrical and mechanical condition of the motor.

SAVING %

LOAD %

  1 TO 15 HP 16 TO 40 HP 41 TO 150 HP
NO LOAD 76% 60% 45%
10% 40% 30% 22%
20% 26% 22% 20%
30% 15% 13% 12%
40% 09% 08% 07%
50% 06% 05% 04%
APPLICATION INDUSTRIES
Petrochemical Plastic Rubber
Chemical General Engineering Paper
Fertilizer Automobile Hotels
Cement Textile Paints
Sugar Tea Dye Intermediate
APPLICATIONS
Compressors Crushers Ring Frames
Centrifuges Agitators & Conveyors Presses
Injection Moulding Machines Cooling Towers M.G. Welding Sets etc.
Shearing Machines Agitators & Conveyors Pug Mills
Cutting Machines Cooling Towers Reactors
Simplex Machines Blowers & Water Pumps Extractor
View Complete Details

Pid Temperature Controller



  • uPID 296 : Two Line PID temperature Controller

  • uPID 196 : One Line PID temperature Controller





Features & specifications



  • Universal selectable Input :- RTD-PT 100 , Thermocouple K Type (Chromel Alumel), Thermocouple J Type (Iron-Constantan), Thermocouple R Type (Pt-PtRh 13%), Thermocouple S Type (Pt-PtRh 10%), Analog 4 to 20mA DC

  • Range : RTD-PT 100 (0.1 *C) -99.9 to 400.0 *C, RTD-PT 100 (1 *C) -99 to 400 *C, Thermocouple K Type 0000 to 1200 *C, Thermocouple J Type 0000 to 750 *C, Thermocouple R Type 0000 to 1750 *C, Thermocouple S Type 0000 to 1750 *C, Analog -999 to 9999

  • Resolution: RTD-PT 100 1 *C or 0.1 *C, Thermocouple K Type 1 *C, Thermocouple J Type 1 *C, Thermocouple R Type 1 *C, Thermocouple S Type 1 *C, Analog Selectable

  • Accuracy: Better than +/- 0.5% of Full Scale

  • Compensation: Automatic Cold Junction Compensation

  • One point calibration for RTD-PT100, One point calibration for all Thermocouples, Two point calibration for 4 to 20mA DC

  • Input sensor selection through front keyboard

  • Control Type : On-Off, PID

  • Control Logic : Heating or Cooling

  • PID Parameter : Auto Tuning or Manual Tuning, Proportional Band, Integral Time, Derivative Time

  • Relay Output : 2 nos. of Relay Output (OPTIONAL), PID action for first Relay only

  • Analog Output : Retransmission or Control 4 to 20mA Output Selectable

  • Four Keys on the front panel for setting of Relay Set Point, Control Logic, Hysterisis in Temperature, Delay in Time, PID Tuning Auto or Manual, PID Parameter Proportional Band, Integral Time, Derivative Time, Input Sensor Selection





Size



  • 96 mm X 96 mm X 65 mm


View Complete Details

Electronic Soft Starter

  • Features Soft Start facility, with initial torque setting by minimum pedestal voltage, ramp time adjustable for setting ramping time, adjustable from 1 to 180 secs
  • Rated Insulation Voltage 600V
  • Rated Operating Voltage 415/440V AC + 10%/ – 15%, 3 phase, 50 Hz
  • Rated control supply voltage 230 V AC + 15%/ – 15%, 1 phase, 50 Hz
  • Recommended load 3 – Phase AC Motor, multiple motors or other loads arenot recommended except under specific circumstances.
  • Overload capacity 115% Continuous, 150% for 10 seconds and 200% for 5 seconds
  • Ambient Temperature During Operation
  • During Storage -40 degC to +70 degC
  • Altitude of Installation 1000 meters (Above 1000m derating had to be done)
  • Degree of protection Main Circuit – IP00, Supply and Control Circuit – IP20
  • Main Circuit Provided with external bypass contactor provision
  • Display LED Seven Segment Display with 4 keys keypad for setting parameters
  • Main Settings Ramp time during start – 1 to 180 sec
  • Ramp time during stop – 1 to 180 sec
  • Pedestal (Initial) voltage – 1 to 60%
  • Current limit – 1.5 to 7 x rated current
  • Signal Relays One C/O relay for bypass contactor
  • Control Circuit Number of digital Inputs – 3 (Start, stop, emergency stop)
  • Protections Internal protection for Overtemperature and transient voltage
  • Voltage rating of thyristors 1400 to 1600 PIV
  • Types of cooling Air-cooled below 250 hp, fan cooled for 250 hp and above.
  • Over temperature protection Normally closed contact output, thermal switch provided for heatsink
  • SCR Protection MOV transient voltage suppressors to absorb high energy voltage transients
View Complete Details

Earth Leakage Relay

  • Features State of Art Microcontroller Based Design, 4 digit Super Bright Seven Segment Display, 3 Keys keypad for program mode
  • Aux. Supply 230 VAC , 50/60 Hz (+/- 10 %)
  • Power Phase 1 Phase
  • Range For Model ELR 3 mA to 30 mA, 0.1 A to 9.99 A, 1 A to 99.9 A
  • Resolution Depends on Current sensing Range
  • Relay output One Change Over , 5 A
  • Dimension Bezel - 96 mm x 96 mm, Depth - 65 mm, Panel Cutout - 92 mm x 92 mm
View Complete Details

Heater Controller

  • Phase 1 Phase, 3 Phase
  • Size On request
  • Features & specifications Isolated from high voltage, Internal overheat protection (optional), RC snubbers included for transient voltage protection
  • Aux Supply 230V AC, 50 Hz
  • Control input signals 4-20 mA / 0-10VDC / 0- 5 VDC
  • Control method Burst & phase angle firing modes
View Complete Details

Vehicle Intelligent Earthing Confirmation System


Static electricity is a frequent source of ignition. An electrostatic charge can be generated while handling conductive liquids or powders. Static charge can lead to the electrical charging of conductive objects such as barrels, filling pipes, tanker trucks, FIBCs (Big Bags) etc. Static Sparks can be prevented by discharging to proper earthing the objects.





Vehicle Intelligent Earthing confirmation System


(Integrated system of ECR-Plus & ECR-2)
Name itself indicates that it is an intelligent system for tanker truck application. Here our Earthing Confirmation System confirms connection of earthing to an Object (Tanker Truck) and also checks earthing loop between earth and tanker during loading and unloading of tanker trucks. Earthing confirmation system operates in stages, first, it checks whether the earthing, guarantees a quick and safe dissipation of electrostatic charge to the earth. Then it dissipates the static residual charge from the tanker to earth, then after it checks, identification of tanker to be earth. Now in any given condition, loss of connection of clamps, or loosening of clamps, damage to conductors happens, the earthing confirmation system will stop the process of loading / unloading with complete command over pump for interlocking without any human interference.






Salient Features of ECR-Plus :



  • Constant monitoring of earth loop between earth and tanker truck

  • Human error Ruled out by tanker verification

  • Interlocking of pump

  • Intrinsically Safe Relay

  • ATEX CERTIFIED

  • CE CERTIFIED


Note : ECR-Plus is also available without tanker identification function (As model ECR-1) for reactor vessels (process equipments) earthing confirmation purpose. Also can be used for Tanker loading/unloading if identification is not required.




ECR-Plus system Includes :



  • FLP/WP Enclosure of Aluminium Alloy

  • Red Indicated Lamp red light glows during earth open condition, vehicle not identified, not proper earthing.

  • Green Indication Lamp green light glows in healthy condition allowing pump to operate loading/unloading

  • One or Two Nos. Stainless Steel Earthing clamp with / without tungsten carbide teeth

  • Earthing Clamp holder

  • Two change over potential free relay








Technical Specification





  • Power Supply : 230VAC OR 110VAC 10% + 15%, 45-65Hz., (Optional 24 VAC)

  • Inputs : (1) True or Verified Earth at loading / unloading Area (2) Probe from Tanker

  • Range : (Intrinsically Safe) Earth Loop Resistance 0 to 10 adjustable through external display console at factory on demand.

  • Permissible Circuit values Ignition Protection class : IIC (1)G [Ex ia Ga] IIB/IIC, IIC (1)G [Ex ib Ga] IIB/IIC

  • Cable Entries : Four at bottom of enclosure.

  • Relay output Rating : Two change over 250 V/ 5A (Resistive Load)

  • Weight : Approx. 6.5 Kg. (without Clamp)

  • Ambient Temperature Max. 55C

  • Cable type : Two single core or two core single cable of 5 mtr. (Option in straight and spiral)

  • Clamp design : SS 304 crocodile type / tungsten carbide (optional)










General FLP Enclosure Certification :



  • Type of Protection : CIMFR / CCOE for Intrinsic Safety (Ex-i)

  • Flame proof (Explosion proof) Ex-d,

  • Area Classification : Zone 1 & 2,

  • Gas Groups : IIA/IIB, T6

  • IP Protection : IP 65 / IP 66

  • Apparatus standard : For Ex-d IS 2148 / 1981 (Re-certification based on IEC 60079 series is under process)

  • Material : Cast Aluminium Alloy LM-6





View Complete Details

Human Body Static Dissipater

  • Power Supply 230 V AC
  • Max Test Voltage 1.5 V DC
  • Type of Ex protection Ex”d”
  • Type of ingress protection IP66
  • Temperature Class T4/T6
  • Interlock contact 1 C/o potential free contact
  • Display bright 1” red display 4 digits
  • Unit size 355 x 270 x 165 are in mm with Gland
  • Overall size 20.5” L x 14.5”H x 8” D
  • Present resistance value 750K ohm
  • Mounting Wall mounting SS plate
  • Handles Test & Ref. Ground handle
  • Power On/Off switch 06 Amp
View Complete Details

Thyristorised Power Factor Panel

  • Features Smooth and Transient free, Reducing energy consumption, Reducing contract demand cost, Maintenance free, Resonance Free, Improves quality of power, by avoiding surges, sag or low voltage
View Complete Details

DC PANEL METER

  • Display Type LED Seven Segment, 4 Digit
  • Features True RMS measurement, Man-machine interface through keypad & display, Auto reset or Manual reset during fault, Annunciation indicates the type of fault, Shunt ratio programmable
  • Protection Over Current / Under Current / Over Voltage / Under Voltage / Over and Under Current
  • Size Panel mountable – 96X96X65mm
View Complete Details

Auto Mains Failure Relay

  • Features Micro controller technology, Withstands a dip to 0V of auxiliary supply for 1 second, Alphanumeric LCD display with keypad for easy of operation, Remote starting and stopping facilities
  • auxiliary supply 7 V to 35Vdc
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Nilesh Patel (Excel Electronics)
  • No. 992/1/17, GIDC Industrial Estate Near Shakti Ice Factory, Makarpura Near By Makarpura Bus Depo, Vadodara, Gujarat - 390011
  • Share us via
Browse Our Products list of Excel Electronics Vadodara, Gujarat
Post Buy Requirement
EE
Vadodara, Gujarat, India
Add Review

Our Products #4494957

LED Seven Segment Display

  • LED seven segment Display
  • Annunciation indicates the type of fault
  • Providing 2.5, 5 & 10C curve for overload
  • With Extra protection class CT (20, 35, 55 mm ID )
  • Modbus RTU protocol RS-485*
  • Reset inhibit Function
View Complete Details

Cyclic Load Energy Saver

  • Features Digital ammeter with auto scanner for three phase currents, Optional features like star-delta timer
  • Supply Voltage Operation 230V ± 10%, 50HZ.
  • Load Sensing Through Current Transformer
  • Protection Over Load, Single Phasing, Unbalance
  • LED Annunciation R, Y, B Phase Current Indication & Delta And Star Mode Indication
  • Delta to Star Changeover Time I-60 sec. settable
  • Start to Delta Change over Time Instantaneous
  • Bypass Automatic Delta to Star Conversion Bypass Through Toggle Switch (except protection)

SCOPE FOR SAVING

Following table shows the scope for saving energy for the motors of different capacity ranges at different loads. The actual values will vary for different ratings of motor and the savings can be higher or lower depending upon electrical and mechanical condition of the motor.

SAVING %

LOAD %

  1 TO 15 HP 16 TO 40 HP 41 TO 150 HP
NO LOAD 76% 60% 45%
10% 40% 30% 22%
20% 26% 22% 20%
30% 15% 13% 12%
40% 09% 08% 07%
50% 06% 05% 04%
APPLICATION INDUSTRIES
Petrochemical Plastic Rubber
Chemical General Engineering Paper
Fertilizer Automobile Hotels
Cement Textile Paints
Sugar Tea Dye Intermediate
APPLICATIONS
Compressors Crushers Ring Frames
Centrifuges Agitators & Conveyors Presses
Injection Moulding Machines Cooling Towers M.G. Welding Sets etc.
Shearing Machines Agitators & Conveyors Pug Mills
Cutting Machines Cooling Towers Reactors
Simplex Machines Blowers & Water Pumps Extractor
View Complete Details

Pid Temperature Controller

  • uPID 296 : Two Line PID temperature Controller
  • uPID 196 : One Line PID temperature Controller
Features & specifications
  • Universal selectable Input :- RTD-PT 100 , Thermocouple K Type (Chromel Alumel), Thermocouple J Type (Iron-Constantan), Thermocouple R Type (Pt-PtRh 13%), Thermocouple S Type (Pt-PtRh 10%), Analog 4 to 20mA DC
  • Range : RTD-PT 100 (0.1 *C) -99.9 to 400.0 *C, RTD-PT 100 (1 *C) -99 to 400 *C, Thermocouple K Type 0000 to 1200 *C, Thermocouple J Type 0000 to 750 *C, Thermocouple R Type 0000 to 1750 *C, Thermocouple S Type 0000 to 1750 *C, Analog -999 to 9999
  • Resolution: RTD-PT 100 1 *C or 0.1 *C, Thermocouple K Type 1 *C, Thermocouple J Type 1 *C, Thermocouple R Type 1 *C, Thermocouple S Type 1 *C, Analog Selectable
  • Accuracy: Better than +/- 0.5% of Full Scale
  • Compensation: Automatic Cold Junction Compensation
  • One point calibration for RTD-PT100, One point calibration for all Thermocouples, Two point calibration for 4 to 20mA DC
  • Input sensor selection through front keyboard
  • Control Type : On-Off, PID
  • Control Logic : Heating or Cooling
  • PID Parameter : Auto Tuning or Manual Tuning, Proportional Band, Integral Time, Derivative Time
  • Relay Output : 2 nos. of Relay Output (OPTIONAL), PID action for first Relay only
  • Analog Output : Retransmission or Control 4 to 20mA Output Selectable
  • Four Keys on the front panel for setting of Relay Set Point, Control Logic, Hysterisis in Temperature, Delay in Time, PID Tuning Auto or Manual, PID Parameter Proportional Band, Integral Time, Derivative Time, Input Sensor Selection
Size
  • 96 mm X 96 mm X 65 mm
View Complete Details

Electronic Soft Starter

  • Features Soft Start facility, with initial torque setting by minimum pedestal voltage, ramp time adjustable for setting ramping time, adjustable from 1 to 180 secs
  • Rated Insulation Voltage 600V
  • Rated Operating Voltage 415/440V AC + 10%/ – 15%, 3 phase, 50 Hz
  • Rated control supply voltage 230 V AC + 15%/ – 15%, 1 phase, 50 Hz
  • Recommended load 3 – Phase AC Motor, multiple motors or other loads arenot recommended except under specific circumstances.
  • Overload capacity 115% Continuous, 150% for 10 seconds and 200% for 5 seconds
  • Ambient Temperature During Operation
  • During Storage -40 degC to +70 degC
  • Altitude of Installation 1000 meters (Above 1000m derating had to be done)
  • Degree of protection Main Circuit – IP00, Supply and Control Circuit – IP20
  • Main Circuit Provided with external bypass contactor provision
  • Display LED Seven Segment Display with 4 keys keypad for setting parameters
  • Main Settings Ramp time during start – 1 to 180 sec
  • Ramp time during stop – 1 to 180 sec
  • Pedestal (Initial) voltage – 1 to 60%
  • Current limit – 1.5 to 7 x rated current
  • Signal Relays One C/O relay for bypass contactor
  • Control Circuit Number of digital Inputs – 3 (Start, stop, emergency stop)
  • Protections Internal protection for Overtemperature and transient voltage
  • Voltage rating of thyristors 1400 to 1600 PIV
  • Types of cooling Air-cooled below 250 hp, fan cooled for 250 hp and above.
  • Over temperature protection Normally closed contact output, thermal switch provided for heatsink
  • SCR Protection MOV transient voltage suppressors to absorb high energy voltage transients
View Complete Details

Earth Leakage Relay

  • Features State of Art Microcontroller Based Design, 4 digit Super Bright Seven Segment Display, 3 Keys keypad for program mode
  • Aux. Supply 230 VAC , 50/60 Hz (+/- 10 %)
  • Power Phase 1 Phase
  • Range For Model ELR 3 mA to 30 mA, 0.1 A to 9.99 A, 1 A to 99.9 A
  • Resolution Depends on Current sensing Range
  • Relay output One Change Over , 5 A
  • Dimension Bezel - 96 mm x 96 mm, Depth - 65 mm, Panel Cutout - 92 mm x 92 mm
View Complete Details

Heater Controller

  • Phase 1 Phase, 3 Phase
  • Size On request
  • Features & specifications Isolated from high voltage, Internal overheat protection (optional), RC snubbers included for transient voltage protection
  • Aux Supply 230V AC, 50 Hz
  • Control input signals 4-20 mA / 0-10VDC / 0- 5 VDC
  • Control method Burst & phase angle firing modes
View Complete Details

Vehicle Intelligent Earthing Confirmation System

Static electricity is a frequent source of ignition. An electrostatic charge can be generated while handling conductive liquids or powders. Static charge can lead to the electrical charging of conductive objects such as barrels, filling pipes, tanker trucks, FIBCs (Big Bags) etc. Static Sparks can be prevented by discharging to proper earthing the objects.

Vehicle Intelligent Earthing confirmation System

(Integrated system of ECR-Plus & ECR-2)Name itself indicates that it is an intelligent system for tanker truck application. Here our Earthing Confirmation System confirms connection of earthing to an Object (Tanker Truck) and also checks earthing loop between earth and tanker during loading and unloading of tanker trucks. Earthing confirmation system operates in stages, first, it checks whether the earthing, guarantees a quick and safe dissipation of electrostatic charge to the earth. Then it dissipates the static residual charge from the tanker to earth, then after it checks, identification of tanker to be earth. Now in any given condition, loss of connection of clamps, or loosening of clamps, damage to conductors happens, the earthing confirmation system will stop the process of loading / unloading with complete command over pump for interlocking without any human interference.

Salient Features of ECR-Plus :

  • Constant monitoring of earth loop between earth and tanker truck
  • Human error Ruled out by tanker verification
  • Interlocking of pump
  • Intrinsically Safe Relay
  • ATEX CERTIFIED
  • CE CERTIFIED

Note : ECR-Plus is also available without tanker identification function (As model ECR-1) for reactor vessels (process equipments) earthing confirmation purpose. Also can be used for Tanker loading/unloading if identification is not required.

ECR-Plus system Includes :

  • FLP/WP Enclosure of Aluminium Alloy
  • Red Indicated Lamp red light glows during earth open condition, vehicle not identified, not proper earthing.
  • Green Indication Lamp green light glows in healthy condition allowing pump to operate loading/unloading
  • One or Two Nos. Stainless Steel Earthing clamp with / without tungsten carbide teeth
  • Earthing Clamp holder
  • Two change over potential free relay
Technical Specification
  • Power Supply : 230VAC OR 110VAC 10% + 15%, 45-65Hz., (Optional 24 VAC)
  • Inputs : (1) True or Verified Earth at loading / unloading Area (2) Probe from Tanker
  • Range : (Intrinsically Safe) Earth Loop Resistance 0 to 10 adjustable through external display console at factory on demand.
  • Permissible Circuit values Ignition Protection class : IIC (1)G [Ex ia Ga] IIB/IIC, IIC (1)G [Ex ib Ga] IIB/IIC
  • Cable Entries : Four at bottom of enclosure.
  • Relay output Rating : Two change over 250 V/ 5A (Resistive Load)
  • Weight : Approx. 6.5 Kg. (without Clamp)
  • Ambient Temperature Max. 55C
  • Cable type : Two single core or two core single cable of 5 mtr. (Option in straight and spiral)
  • Clamp design : SS 304 crocodile type / tungsten carbide (optional)

General FLP Enclosure Certification :

  • Type of Protection : CIMFR / CCOE for Intrinsic Safety (Ex-i)
  • Flame proof (Explosion proof) Ex-d,
  • Area Classification : Zone 1 & 2,
  • Gas Groups : IIA/IIB, T6
  • IP Protection : IP 65 / IP 66
  • Apparatus standard : For Ex-d IS 2148 / 1981 (Re-certification based on IEC 60079 series is under process)
  • Material : Cast Aluminium Alloy LM-6
View Complete Details

Human Body Static Dissipater

  • Power Supply 230 V AC
  • Max Test Voltage 1.5 V DC
  • Type of Ex protection Ex”d”
  • Type of ingress protection IP66
  • Temperature Class T4/T6
  • Interlock contact 1 C/o potential free contact
  • Display bright 1” red display 4 digits
  • Unit size 355 x 270 x 165 are in mm with Gland
  • Overall size 20.5” L x 14.5”H x 8” D
  • Present resistance value 750K ohm
  • Mounting Wall mounting SS plate
  • Handles Test & Ref. Ground handle
  • Power On/Off switch 06 Amp
View Complete Details

Thyristorised Power Factor Panel

  • Features Smooth and Transient free, Reducing energy consumption, Reducing contract demand cost, Maintenance free, Resonance Free, Improves quality of power, by avoiding surges, sag or low voltage
View Complete Details

DC PANEL METER

  • Display Type LED Seven Segment, 4 Digit
  • Features True RMS measurement, Man-machine interface through keypad & display, Auto reset or Manual reset during fault, Annunciation indicates the type of fault, Shunt ratio programmable
  • Protection Over Current / Under Current / Over Voltage / Under Voltage / Over and Under Current
  • Size Panel mountable – 96X96X65mm
View Complete Details

Auto Mains Failure Relay

  • Features Micro controller technology, Withstands a dip to 0V of auxiliary supply for 1 second, Alphanumeric LCD display with keypad for easy of operation, Remote starting and stopping facilities
  • auxiliary supply 7 V to 35Vdc
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Nilesh Patel (Excel Electronics)
  • No. 992/1/17, GIDC Industrial Estate Near Shakti Ice Factory, Makarpura Near By Makarpura Bus Depo, Vadodara, Gujarat - 390011
  • Share us via