Contactor switched Automatic Harmonic Filter Panel ( AHPFC Panel ) is passive tuned filter systems using Frako, Germany make contactors & Clariant make Thyristor switched modules. Automatically controlled power factor regulation, low installation cost. Harmonic filters are in detuned mode (133Hz, 189Hz) and effectively reduce at 5th, 7thharmonics inturn l2R and eddy current losses in the systems. We can achieve any target power factor with this scheme. Results in potential savings in electrical bill with the convincing payback period 12 months.
HT automatic Harmonic Power Factor Correction Panels (HT AHPFC indoor systems) using FRAKO / CPSL make capacitors & reactors. Clariant is pioneer in proving complete (tuned + detuned) HT AHPFC scheme with advance technology and latest state of art in technical collaboration with FRAKO Germany. This effectively reduces the losses at HTbus avoid over compensation, improve system stability by injecting reactive power in line with Network load require-ment in auto mode with EMR 9606 AHPFC Relay.
Features :
IEC 60871-4 HT Capacitors are manufactured with ALL FILM TECHNOLOGY. The dielectric material consists of high quality polypropylene film sandwiched between aluminum foil electrodes. A large number of capacitor elements are assembled to form a capacitor unit, also known as a winding pack. The elements can be provided with internal / external fuses. Each capacitor unit is permanently connected to a discharge resistor. The winding packs are housed in a sheet steel casing, which is filled with a high quality, environmentally sound impregnating oil. Residual moisture and oxygen are removed from the winding pack in a drying and impregnation process taking place under vacuum at an increased temperature and lasting several days. The Capacitor comply with the requirements of IEC 60871-1, IEC 60871-2 & IEC 60871-4
Features :
Fast Acting Thyristor Switched Automatic Harmonic Filter Panel (RTPFC Panel) is real time passive tuned filter systems using Clariant make Thyristor switched modules. Capacitor Switching at precise Zero current crossover threshold, means : "NO" inrush current at switching "No Instant", No generation of voltage or current spiker. surges and harmonics. Instant correction of load power factor. The response time could be as small as 20 mili seconds. Better control over MD KVAr compensation help in achieving substantial saving in Electricity Bills by reducing KVAh and rKVAh consumption.
Features :
Applications :
Contactor switched Automatic Harmonic Filter Panel ( AHPFC Panel ) is passive tuned filter systems using Frako, Germany make contactors & make thyristor switched module.
Automatically controlled power factor regulation, low installation cost. Harmonic filters are in detuned mode (133Hz, 189Hz) and effectively reduce at 5th, 7thharmonics inturn l2R and eddy current losses in the systems. We can achieve any target power factor with this scheme. Results in potential savings in electrical bill with the convincing payback period 12 months.
Outdoor HT harmonic filter capacitor bank systems using FRAKO / CPSL make capacitors & reactors. High voltage power capacitor units include a wide range of one and three-phase all film power and surge protection capacitors. Featuring the most modern technology, they are produced to meet the requirements of different climatic and operating conditions. They can be open or enclosed, High or low power, Fixed power, Integrated or for use with individual motors.
FRAKO Make LT capacitors are having Features of :
Applications :
Salient Features and Benefits :
Features :
Benefits of Hybrid System :
Power Factor Control Relay- FRAKO make power factor control relays are micro-processor based & advanced features with harmonic display. This can be interfaced with all types of communication protocols.