Our Products
Flow Meters
2 Products availableFuel Injection System
2 Products availableProcess Control Systems & Equipment
2 Products availableLevel Transmitters
1 Products availableElectrical & Electronic Testing Devices
1 Products availableLeading Manufacturer, Supplier & Retailer of Ultrasonic Portable Handheld Flow Meter, Woltman Magnetic Driven Flow Meters, Ultrasonic Open Channel Flow Meter, Pulse Oval Gear Flow Meter and Digital Oval Gear Flow Meter.
Description :
Features :
Applications :
Technical Specification
Linearity | 0.005 |
---|---|
Repeatability | 0.005 |
Accuracy | Normally ±1% of reading for velocity above 3.3ft/s (1m/s), or ±0.03ft/s (±10mm/s) for velocity smaller than 3.3ft/s (1m/s) |
Velocity range | -52ft/s ~ +52ft/s (-16m/s ~ +16m/s), bi-directional |
Pipe Size | 3/4" ~ 240" (DN20mm - DN6,000mm) |
Pipe Material | All metals, most plastics, lined pipes |
Liquid Types | Virtually all clean liquids and liquids with minor solids (<10,000ppm). Full pipes |
Liquid Temp | 32oF ~ 212oF (0o C ~ 100oC) or 32oF ~ 312oF (0oC ~ 150oC), depending on transducer type |
Response Time | 0-999 seconds, user-configurable |
Measuring Units | English (U.S.) or metric |
Display format | LCD with backlight,4x16 letters |
Totalizer | Three 7-digit totalizers for net, positive, and negative flows respectively |
Transducer cable | Standard 2×5m.Longer cable available upon request. |
Data logger | Built-in data logger can store over 2000 lines of data |
Protecting case | Aluminum alloy protective case. Suitable for normal and harsh environment |
Case Size | 7.9" x 3.6" x 1.3" (200mm x 92mm x 32mm) |
Main unit weight | Very light, real handheld type. Only 1.2 lbs (538 g) with batteries |
Power supply | 3 Ni-H built-in batteries. When fully recharged it lasts over 10 hours. |
Graph Image
Features :
Line Size & Flow Range
Line Size | MM | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
inches | 2´´ | 2.1/2´´ | 3´´ | 4´´ | 5´´ | 6´´ | 8´´ | 10´´ | 12´´ | |
Metro logical | R(Q3/Q1≤100) Q2/Q1≤(1.6,2.5,4,6.3) | |||||||||
Flow range Q3 | M3/h | 25 | 40 | 63 | 100 | 160 | 250 | 400 | 630 | 1000 |
Details
Maximum permissible error Between Q1and Q2 (excluded) |
±5% |
Maximum permissible error between Q2(included)and |
±2% with water temperature>30o Q4 ±3% with water temperature>30o |
Technical Specification
Temperature class | Cold water:0o~40 Hot water:40o~90o | ||||
Nominal pressure | Bar | 43389 | 43389 | 43389 | 43389 |
Min reading | m3 | 0.001 | 0.001 | 0.001 | 0.001 |
Max reading | m3 | 9999999 | 9999999 | 9999999 | 9999999 |
Weight | kg | 43385 | 43448 | 13.6 | 15 |
Pulse options | l/imp. | -328437 | -328437 | -328437 | -328437 |
Details :
Advantages :
Technical Specification
Range | 0.1l/s99999.99 m3/h |
---|---|
Cumulative Flow | biggest4290000000.00 m3 |
Max range for level | 3m |
Accuracy for level | 0.005 |
Resolution | 3mm or 0.1% bigger |
Accuracy for Flow | Standard weir - 15% (Meet the requirements of national standard weir and channels) Non-standard weir - 1030% |
Power supply | Standard - 24VDC 100m Aoptional - 220V AC+15% 50Hz |
Environmental pressures | Standard atmospheric pressure |
Environment humidity | ≤90%RH Non-condensing |
Process temperature | -20 80o |
Communication Outout | 4 – 20 mm, Optional - 485/232/MODBUS protocol |
Protection Grade | LED:IP65 Probe: IP68 |
Graph Image
For measuring the water level and total depth in boreholes, wells, reservoirs etc. for the measurement the bob is lowered to the water level. When touching he level, a sensor effects the illumination of a signal lamp. On request, an additional acoustic signal will be released by a buzzer.
Features :
Applications :
Technical Specification
Shell material | ABS, Metallica |
---|---|
Shell color | Orange, Blue, |
Measurement range | 30m,50m,100m,200m,300m,400m |
Battery power | 9V lithium battery |
Instrument for temperature | -20~+60 |
The response time for output | ≤1ms |
Indicationmarking | Mtr., mm std. scale |
Adaptation range of water quality | 10μω~1000μω |
Measurement signal | LED; Optional : Buzzer, Electricity meter |
Construction of cable | High tensile virtually non-expandable, non-stretch, PE insulated coaxial cable (mtr. Marking) PE insulated flat tape (mm marking) |
Rated voltage | 300V |
Testing Voltage | 2000V |
Insulation resistance | >200MΩ×km |
Description :
E = K.B.V DWhere E - Induced voltage - Volume flow is calculated by equation :
Applications :
Technical Specification
Pipe Sizes | DN 10 to DN 1000 |
---|---|
Media Conductivity (Min.) | 10 µS/cm |
Pressure | PN 40 up to DN 80, PN 16 up to DN 200, PN 10 up to DN 1000 |
Temperature (PTFE Liner) |
0 - 180 C with Remote 0 - 120o C with Integral 0 - 90oC max for other |
Pipe | SS 316 (Non-magnetic ) |
Liner | PTFE / Rubber |
Electrode | SS / Hastelloy C / Ta / Ti |
Flanges | Carbon Steel / SS 304 / SS 316 |
Coil Housing | Carbon Steel / SS, Epoxy painted |
Transmitter | Cast Aluminium (LM6) , Epoxy painted |
Power Supply | 240V AC, 50Hz |
Analog Output | 4-20 mA DC |
Pulsed Output (Optional) | Low Pulsed Rate Output 10 to 36000 pulses per hour |
Communication Port (Optional) | RS - 232 / RS - 485 MODBUS RTU Protocol |
Maximum Load Resistance | 1000 ohm |
Response Time | 5 seconds |
Flow Velocity Range | 0.3 to 10 m/s |
Protection | IP - 65 |
LCD Display | 16 X 2 (Two Line) Backlit LCD 4 Digit - Flow Rate 8 Digit - Totaliser |
Accuracy | ±0.5% of measured value (normal) |
Details
DN | m³ / hr | LPM | DN | m³ / hr | LPM |
10 | 0.282 | 4.711 | 125 | 44.18 | 736.198 |
15 | 0.636 | 10.601 | 150 | 63.61 | 1060.125 |
20 | 1.13 | 18.846 | 200 | 113.08 | 1884.667 |
25 | 1.766 | 29.447 | 250 | 176.69 | 2944.792 |
32 | 2.909 | 48.247 | 300 | 254.43 | 4240.500 |
40 | 4.523 | 75.386 | 350 | 346.31 | 5771.792 |
50 | 7.068 | 117.791 | 400 | 452.32 | 7538.668 |
65 | 11.944 | 199.1 | 450 | 572.47 | 9541.98 |
80 | 18.092 | 301.546 | 500 | 706.75 | 11779.169 |
100 | 28.27 | 471.166 | 600 | 1017.72 | 16962.003 |
Graph Image