We are one of the well-known Mechanical Pediatric Ventilation Suppliers. We present pediatric ventilator which is widely used in noted hospitals throughout the world. We present reliable pediatric mechanical ventilation which strictly works on the cutting-edge technology. We are also a prominent pediatric mechanical ventilation exporter. We have considerable expertise in dealing with wide gamut of pediatric ventilator. Are you afraid for the price? We present pediatric ventilator at the most acceptable price.
A crisp and clear digital Bar graph precisely indicates the actual pressure delivered to patient long with PEEP and the set Trigger level. Trigger The PC900 comprises a Pressure Trigger mechanism, while the PC900 comprises pressure as well as Flow Trigger mechanism. FLOW TRIGGERING MECHANIS: The Shreeyash PC 903 incorporate a duel flow system, During expiratory phase a continues flow passes a through the ventilator circuit and return back to ventilator (i.e. delivered flow = returned flow). If the patient initiates a breather, part of the delivered flow goes to the patient and thus the returned flow is less than the ventilator as an patient effort and it instantly supplies additional flow and thus a breather is assisted. When the patient triggers the PC903, the flow accelerates such that the set PIP is achieved. As the flow starts to decelerate and when it reaches the set termination value (settable from 10% to 25% of peak flow) the PC903 cycles in to expiration. Provision of Bias Flow to provide ready gas of set FIO2 during patient triggering. This helps in improving the overall sensitivity of the ventilator: It also helps in washing out the CO2 in more effective manner and helps to maintain the PEEP. The Bias flow can be set to neonatal & pediatric mode by using the soft touch keys. Help: When this key is depressed, the user can access information regarding setting parameters in specific diseases. Formula Key: Indicates various formulae like MAP, Compliance, Oxygen Index, Desired Pa CO2 etc. that may be useful to the clinician. Compressor: Noise less oil free dry air compressor: Prefilters incorporated for pure & hygienic air. Inbuilt reservoir tank that stores the air & shuts the compressor On & Off. This helps in reducing the ware & tare of the compressor, saves your electricity, & can run the ventilator for 10 minutes (depending on the setting) in case of power failure. CPAP Plus Pressure Support No mandatory breathe, Patient Breaths through the Bias Flow and sets his own Rate and I:e, ratio Pressure support helps to over come airway resistance and inadequate pulmonary effort and is added on top of the CPAP During inspiration limb when a patient effort is sensed, thus makes it easier for the patient to take a preesure support Breathe. Auto ModeTHe unique facility of auto mode in the PC900/903 ensures no harm to the patient suffering tachyapnea. It take care that each efforts of the baby is supported, but also ensures that the MAP does not increase. simultaneously it delivers mandatory breathes to ensures adequate ventilation. Working Pressure: The PC900/903 works on very low preesure ensuring utmost safety &economy of gases.It works only on 1.5 psi (100cmH2o)as compared to 30 psi(2100 cm H20)used by comtemporary .Also it does not use gas supply to operate ventilator. Tidal Volume (only in PC903)Instead of placing a flow sensor either at inspiratory end or expiratory end, the pc903 has incorporated a flow sensor at the pxoximal end .This ensures exact indication of delivered tidal volume, exhated volume and above all the flow triggering mechanism becomes more sensitive. even a slight change in the bias flow is detected by the flow transducer & a breathe is triggered. The spontaneous period % can be set from 60, 65, 70, 75% of the respiratory cycle in simv mode .This informs the user regarding the window time of Simv and spontaneous period. Preesure support :Can be set up to 15 cm H2O above PEEP A I.C.U display guides the user in setting various parameters of a selected mode. It also indicates various malfunctions and messages like " low airway pressure, high airway preesure, patient in apnea, mean airway preesure, inspiratory pause , sigh breathe, spontaneous and SIMV mode, biasww flow on , mode ready , prees start, etc. An unique and easily removable humidifier is incorporated to wwarm and humidify the blended gas that is delivered to patient .A special servo control mechanism is provided to warm the gas to the desired temperature. A respective LED on each mode key constantly indicates the selected mode of PC 900 .The user can always shift the mode and can also change the parameters "ON LINE" to enchance his efficacy and patients comfort.