My ExportersIndia

For Buyer

For Seller

For Help

Starters

We offer a complete product range of MANUALLY OPERATED MINI MOTOR STARTER, Direct on Line Motor Starter and Motor Starters

Manually Operated Mini Motor Starter

Offers manually operated mini motor starter.Type: gf-1range: 0.5 to 7.5 hp ght's gf-1 manually operated motor starter is suitable for single-phase motors upto 2hp and three phase motors upto 7.5hp. The starter operates on quick break & trip free mechanism & is designed for smooth & reliable performance. Range wide range of relays is available depending on various ac loads. For actual range see relay section table. Overload trip reset once the relay has tripped due to overload the starter cannot be reset until the bimetal elements have cooled down sufficiently. Contact system the silver alloy tipped contacts ensure long electrical life & can be easily accessed for inspection or replacement. Applications gf-1 starters are most economical & have wide applications. They are perfectly suited for motor installations where no-volt coil or remote onoff is unnecessary or undesirable. Some applications include switching & overload protection of air compressors, exhaust fans, unattended pumps, etc.
View Complete Details

Direct On Line Motor Starter

Offers direct on line motor starter.Type: gl - 2 gl - 3range: 10 to 30 hp gl - 2 type " ganga" d.o.l motor starters have robust construction and offers smooth and reliable performance. They are designed to meet the most stringent requirements of both industrial and agricultural fields. These motor starters comply with requirements of is standards. Thermal overload relay the gl - 2 relay consists of bimetallic elements, which are individually calibrated & tested for precise operation. An extra 'no' contact is provided to give clear warning when overloading of motor occurs. Once they relay has tripped due to overload the starter cannot be reset until the bimetal elements have cooled down sufficiently. Contact system the silver alloy tipped contacts ensure long electrical life & are bounce free when closed. They can be easily accessed for inspection or replacement. Magnet system & coil laminated 'e' stampings are used for construction and are designed for low loss. Shading rings are provided to reduce hum & chatter. Coils are layer wound and are designed for long life. They consume less power & can withstand wide voltage fluctuations particularly in rural areas.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us