Frequency Converters
















60Hz or any other Power Frequency source can be built.
Variety of frequencies are required for machines / equipments made in USA .
India has a fixed 50Hz power source.
And 60 Hz can be generated only through FREQUENCY CONVERTERS.
View Complete Details

DC Power Supply






















Varieties :
1) Unregulated / Unfiltered.
- Suitable for Power Supply to the Relays / Contactors / Solenoids, etc.
Controlled- Regulated :
- Filtered with Thyristor Control Technique.
- Suitable for General Purpose DC Loads like Low PowerElectroplating, Electrical Component
Testing, etc.
- These Power Supplies exhibit Very Low amount of Ripples, suitable for Precision Low
Power Electroplating, PLC or critical applications, for Noise Free environment for Sensitive areas, etc



Regulated and Controlled, Filtered DC Power Supplies :












Industrial Ruggedity, Reliabilityand looks.

Theyare " Thyristor Controlled, SMPS&Linear types. " Good regulation and very low amount of ripple can be achieved. Input can be single or three phase.Provision ofPotentiometers for Voltage and Current Control and meters.
CVCC Design.





View Complete Details

Cranker And Rectifiers













Engine Testing Machines & Accessories, Vehicle Testing Machines, Automotive industry, Diesel Generators, Rectifier, DC Power supply, Electroplating, etc.

These are Heavy Duty Rectifiers used in Engine Testing applications
























Normally an Engine ( Diesel / Petrol ) operate on Batteries in the vehicles. However, in Industry the Rectifiers are preferred for the ruggedness, durability, repeated operations, portability, variety of voltages and currents, indications, measurements, safeties, etc.
Input :3 Phase, 415 V.
Output :12 V or 24 V at 300 amps.2000 Amps.
24V 1600 amp Cranker Rectifier for Engine Testing

View Complete Details

Servo Voltage Stabilizers














Servo Voltage Stabilizersare used in industry for variety of machines to perform better at stabilized voltages. Many CNC machines / Computerised machines / medical- surgical machines, etc. require voltage accuracy as well as stability.


Stabilizers ranging from 1 KVA to 600 KVA are made as per customer requirement.
At higher ranges the stabilizers are OIL Cooled.
View Complete Details

Mag Demag Controller






















These are Magnetise and Demagnetise units for Electromagnetic Chuck.
The Electromagnetic chucks are used to HOLD the job in surface finishing machining operations.
Input :230 V ac Single Phase.

Output :110 V DC at 2 amps. or 110 V DC at 6 amps.



Normally MAG process continues for a long time ( minutes to hours ) and once the surface finishing is over, the job needs to be released from the chuck. Now the procedure of DEMAG starts, which removes the residual magnetism in the chuck and the job gets released. The DEMAG process takes around 20 seconds.

























The operations are without any Electromechanical relays in the output DC line. Both the MAG and DEMAG procedures are through Electronic Switches. Hence, the durability is high.



































Power SupplyUnit for Electromagnetic & Electro Permanent Magnetic Chucks
110V DC Power Supply is required for Electromagnetic Chucks. The Ampere rating starts normally from 2 amps upto 20 amps. These power supplies operate on 230V ac Single Phase or 415 V 2 phase, ac 50 Hz. DC Voltage can be varied and set as per requirements. The magnetic force generated by a CHUCK varies as per the DC Voltage. Power of a CHUCK can be controlled. Power supply Unit is continuously connected to the Magnetic Chuck.
600 V DC Power Supply is required for Electro Permanent magnetic ( EPM ) Chucks. The 600 VDC is discharged into a winding coil of EPM chuck. EPM coil resistance varies from 1 Ohm to 6 Ohms. The discharge current is in the range of 100Amp to 600 Amps. These power supplies operate on 230V ac Single Phase, ac 50 Hz. DC Voltage can be varied and set as per requirements. A magnetic force generated by a CHUCK varies as per the DC Voltage. Power of a CHUCK can be controlled. User can activate the Magnetic Chuck and disconnect the Power Supply Unit.
Power Supply For Magnetic Lifters
It is similar to a Power supply for EPM chuck.
Applications :
Milling Machines, Grinding Machines, Material Lifting, Raw Material Handling, Scrap Handling, Scrap Sorting, Finished goods handling, etc.


View Complete Details

Three Phase Power Controller

This controller operates on a 3 phase line to keep the primary voltage of a 3 phase transformer constant. This is a Thyristor based Controller, especially made for Electroplating operations. Electroplating process is more efficient if the voltage DC and its current are maintained at a desirable or set level. To work with the unstable voltage environment at the 3 phase incoming side, thyristor control technique is the best choice.



Other Applications :Industrial heater control, soft starter.


Only Controls are also avilable, hence a user can use his power circuit and other items and get the related results.


View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Sudhanshu Shrikhande (GAYATRI ENGINEERS)
  • 30-ELECTRONIC CO-OP. ESTATE GROUND FLOOR PUNE-SATARA ROAD, Maharashtra - 411009, India
  • Share us via
Browse Products / Services list of GAYATRI ENGINEERS Pune, Maharashtra
Post Buy Requirement
GE
Pune, Maharashtra, India
Add Review

Products / Services #3839051

Frequency Converters

60Hz or any other Power Frequency source can be built.
Variety of frequencies are required for machines / equipments made in USA .
India has a fixed 50Hz power source.
And 60 Hz can be generated only through FREQUENCY CONVERTERS.
View Complete Details

DC Power Supply

Varieties :
1) Unregulated / Unfiltered.- Suitable for Power Supply to the Relays / Contactors / Solenoids, etc.
Controlled- Regulated :
- Filtered with Thyristor Control Technique.- Suitable for General Purpose DC Loads like Low PowerElectroplating, Electrical ComponentTesting, etc.- These Power Supplies exhibit Very Low amount of Ripples, suitable for Precision LowPower Electroplating, PLC or critical applications, for Noise Free environment for Sensitive areas, etc

Regulated and Controlled, Filtered DC Power Supplies :

Industrial Ruggedity, Reliabilityand looks.

Theyare " Thyristor Controlled, SMPS&Linear types. " Good regulation and very low amount of ripple can be achieved. Input can be single or three phase.Provision ofPotentiometers for Voltage and Current Control and meters.CVCC Design.

View Complete Details

Cranker And Rectifiers

Engine Testing Machines & Accessories, Vehicle Testing Machines, Automotive industry, Diesel Generators, Rectifier, DC Power supply, Electroplating, etc.

These are Heavy Duty Rectifiers used in Engine Testing applications

Normally an Engine ( Diesel / Petrol ) operate on Batteries in the vehicles. However, in Industry the Rectifiers are preferred for the ruggedness, durability, repeated operations, portability, variety of voltages and currents, indications, measurements, safeties, etc.
Input :3 Phase, 415 V.
Output :12 V or 24 V at 300 amps.2000 Amps.
24V 1600 amp Cranker Rectifier for Engine Testing
View Complete Details

Servo Voltage Stabilizers

Servo Voltage Stabilizersare used in industry for variety of machines to perform better at stabilized voltages. Many CNC machines / Computerised machines / medical- surgical machines, etc. require voltage accuracy as well as stability.

Stabilizers ranging from 1 KVA to 600 KVA are made as per customer requirement.
At higher ranges the stabilizers are OIL Cooled.
View Complete Details

Mag Demag Controller

These are Magnetise and Demagnetise units for Electromagnetic Chuck.
The Electromagnetic chucks are used to HOLD the job in surface finishing machining operations.
Input :230 V ac Single Phase.

Output :110 V DC at 2 amps. or 110 V DC at 6 amps.

Normally MAG process continues for a long time ( minutes to hours ) and once the surface finishing is over, the job needs to be released from the chuck. Now the procedure of DEMAG starts, which removes the residual magnetism in the chuck and the job gets released. The DEMAG process takes around 20 seconds.

The operations are without any Electromechanical relays in the output DC line. Both the MAG and DEMAG procedures are through Electronic Switches. Hence, the durability is high.
Power SupplyUnit for Electromagnetic & Electro Permanent Magnetic Chucks
110V DC Power Supply is required for Electromagnetic Chucks. The Ampere rating starts normally from 2 amps upto 20 amps. These power supplies operate on 230V ac Single Phase or 415 V 2 phase, ac 50 Hz. DC Voltage can be varied and set as per requirements. The magnetic force generated by a CHUCK varies as per the DC Voltage. Power of a CHUCK can be controlled. Power supply Unit is continuously connected to the Magnetic Chuck.
600 V DC Power Supply is required for Electro Permanent magnetic ( EPM ) Chucks. The 600 VDC is discharged into a winding coil of EPM chuck. EPM coil resistance varies from 1 Ohm to 6 Ohms. The discharge current is in the range of 100Amp to 600 Amps. These power supplies operate on 230V ac Single Phase, ac 50 Hz. DC Voltage can be varied and set as per requirements. A magnetic force generated by a CHUCK varies as per the DC Voltage. Power of a CHUCK can be controlled. User can activate the Magnetic Chuck and disconnect the Power Supply Unit.
Power Supply For Magnetic Lifters
It is similar to a Power supply for EPM chuck.
Applications :
Milling Machines, Grinding Machines, Material Lifting, Raw Material Handling, Scrap Handling, Scrap Sorting, Finished goods handling, etc.
View Complete Details

Three Phase Power Controller

This controller operates on a 3 phase line to keep the primary voltage of a 3 phase transformer constant. This is a Thyristor based Controller, especially made for Electroplating operations. Electroplating process is more efficient if the voltage DC and its current are maintained at a desirable or set level. To work with the unstable voltage environment at the 3 phase incoming side, thyristor control technique is the best choice.

Other Applications :Industrial heater control, soft starter.

Only Controls are also avilable, hence a user can use his power circuit and other items and get the related results.