Post Buy Requirement
GE
Chennai, Tamil Nadu, India
Verified Add Review

Other Products / Services #1268905

Needle Valve

NEEDLE VALVE

GAYATRI's needle valves are especially suitable where both a reliable cut and a steady fluid flow are required. They have been designed to satisfy multiple industrial applications: Back-seat valves (CP-01, CP-12), compact design integral bonnet valves (CP-15), gas valves with no-maintenance required (RG-90) and the strongest valves, capable of withstanding the harshest conditions (CP-20) or the most corrosive environments (AC-02).

View Complete Details

Pulp Sampling Valve

PULP SAMPLING VALVE

GAYATRI manual pulp sampler have unique opening mechanism that ensures fool-proof operation and accurate sampling at low cost. Particularly useful for pulp sampling in conjunction with laboratory calibration of consistency, brightness and residuals transmitters. These samples operate in pressurized pipes in the 0-8% consistency range.

View Complete Details

Ball Valves

GAYATRI's ball valves are designed to allow a quick opening and close of the flow, as well as to ensure a perfect sealing for liquids and gases. They are manufactured in several sizes, connections and materials to be used in many applications: water treatment, chemical plants, laboratories, gas companies, control panels, instrument insulation, test benches, hydraulic or pneumatic systems, and in many other instrumentation and research areas.
View Complete Details

WAVELENGTH NEPHELOMETER

The Aurora-3000 is the instrument of choice when analysis is required on a number of different contributors to air pollution or for studies regarding global warming using backscatter.

Using an innovative LED light source, the Aurora-3000 simultaneously measures at 525nm (green), 450nm (blue) and 635nm (red) to enable wide and in-depth analysis of particular matter.

Aurora 3000 includes backscatter measurement that allows both standard integrating measurements of 10-170 but also just the back scatter 90-170.

The Aurora 3000 allows the analysis of parameters (backscatter/forward scatter) involved in climate studies and specifically global radiation balance. Furthermore the Aurora 3000 is relevant for general air quality studies such as pollution sources comparison.

And also AURORA-1000 INTEGRATING NEPHLOMETER is available with us.

View Complete Details

OXIDES OF NOX ANALYZER

The new Serinus 40 Oxides of Nitrogen (NO ) analyzer is the next generation in ambient gas monitoring technology. The Serinus 40 Oxides of Nitrogen analyzer uses proven chemiluminescence technology to measure NO in ambient air (LDL

View Complete Details

MOISTURE/O2 ANALYSIS SYSTEM

The Series 8800 Trace Moisture Analyzers detect moisture from -100 C to ambient dewpoint levels of +20 C on either a continuous or spot checking basis. The user can select the moisture analysis readout to be displayed as Deg C, Deg F, ppm -- and for natural gas applications -- in lbs of H2O/million cft or g/m3. The moisture sensor employs unique Hyper Thin Film (HTF)T technology which offers structural improvements in Al2O3 sensor design. These structural changes provide increased sensitivity, greater stability, and a quicker response time. The 8800 Series can be applied to detect moisture on either gas or liquid phase applications.

Applications: Air separation; Glove boxes; Heat treating furnaces; Dryers; Polyethylene Plants

8800A

Flush mount DIN enclosure with connections made via a pluggable screw terminal block

8800B

Wall mount N4X (IP65) enclosure with connections made via 3 bottom watertight fittings

8800P

Portable battery operated design available in a Standard Version, I/O Version, and I/S Version (I/S version suitable for hazardous areas)

8800T

Low-cost, loop powered 4-20 mA transmitter design with built-in LCD display

8800NG Moisture system for natural gas

View Complete Details

Liquid Analytics

The Series LXT is comprised of microprocessor based, loop powered process transmitters designed to provide liquid measurement and control in its simplest form. The units are provided in watertight NEMA-4X and NEMA-7C (LXT-280 only) configurations which can be panel, universal or hand-rail mounted in the field.

Applications:
Power Industry - Heat exchanger leaks; Condensate monitoring; Cooling tower H2O control;
Boiler feedwater control Pulp & Paper - Demineralizer; Digester; Bleach plant;
Recovery & Waste Water Water Treatment - Influent monitoring; Reverse Osmosis & Desalinization plants Food & Beverage - pH in fermentation process;
DO in carbonated beverages Pharmaceutical - Clean-in-Place (CIP) conductivity

LXT-220 AC powered, feature-rich controller, NEMA-4X

LXT-230 DC powered transmitter, NEMA-4X

LXT-280 DC powered transmitter, CSA / FM approved

And also we provide these products

  • Sensing capabilities
  • Combustible & oxygen leak detection system
  • Electrochemical, paramagnetic & zirconium oxygen
  • Infrared analyzer/system
View Complete Details

Flue Gas Analysers

The PEM 9004 is a gas analyzer capable of directing and calculating up to ten(10) gas parameters, housed in a light. Weight and robust case. An integral sample pump draws a sample through the included 316SS probe and gas treatment system built in to the case. The analyzer utilizes microprocessor-based electronics with a back-lil LCD display and membrane panel. To provide easy-to-view readings and navigation of functions.

View Complete Details

UV ANALYZERS SYSTEM

5000 Series Near Infrared (NIR) Photometer The Series 5000 NIR Photometer utilizes a chopper stabilized single sample cell, dual wavelength design to continuously monitor water and organic compounds (in the liquid phase) that have distinct absorbance peaks within the NIR region of the light spectrum. In addition to providing inherent stability, this design provides automatic compensation for the background components with an absorbance overlapping that of the component of interest. The Series 5000 is set apart from other commercially available NIR analyzers by its unique sample cell pre-heater design that ensures stable performance over a wide temperature range. The Series 5000 is available in either general purpose or hazardous configurations.

Applications: PPM or percent level detection of H2O in organics / solvents in petrochemical plants (EDC/VCM, HOAC, MCB, etc.)

5000B Wall mount NIR - folded optics

5020 Fully explosion proof NIR

6000B Wall mount UV

6020 Fully explosion proof UV

6200 Total sulphides analyzer

6400 Fluorescent SO2 analyzer

6600 Oil in Water analyzer system

6650 Oil in Water analyzer, fluorescence probe

View Complete Details

Total Organic Carbon Analyzers

The Series 6700 covers a complete range of Total Organic Carbon (TOC) Analyzers capable of addressing a wide variety of industrial applications for process and environmental compliance purposes. Depending on the application, TAI can provide an recommendation as to which technique would be best suited to continuously detect TOC within your process. UV / Heated Persulfate Combustion Ozone Promoted Ultrapure Each configuration is available with an advanced Microsoft Windows-based computer with touch screen control. The robust and reliable Infrared CO2 analyzer is the heart of each design. It provides specific, interference-free CO2 detection, has no moving parts, and is extremely easy to access and service, as required. Depending on your specific needs, TAI is capable of providing a complete turn-key system solution suitable for use in hazardous, outdoor environments.

Applications: Boiler feedwater; Cooling water; Wastewater; River water; Pharmaceuticals; Process control

View Complete Details

PUF XAD SAMPLER

The HiVol 3000 PUF Sampler provides a flexible platform for sampling organic compounds and monitoring basic meteorological parameters.

The PUF utilize poly-urethane foam (PUF) to collects particulate matter and store it in a sterile environment for later analysis.

The HiVol 3000 PUF unit is a reliable, durable and proven sampler using volumetric flow control to maintain consistent flow and collect a truly representative sample of particulate matter.

The HiVol 3000 XAD Sampler provides a flexible platform for sampling organic compounds and monitoring basic meteorological parameters.

The XAD sampler collects a wider variety of compounds (than a PUF) on a Hydrophobic Polyaromatic resin (XAD). The HiVol 3000 XAD unit is reliable, durable and proven sampler using volumetric flow control to maintain consistent flow and collect a truly representative sample of particulate matter.

Optional attachments allow the sampler to measure wind speed and direction which can then be used as triggers to capture other meteorological parameters.

View Complete Details

Temperature Controller

  • 4 Digit Micro Controller Based Linearized and High Accuracy Selectable Inputs J, K, R, S, T, Pr-100, /
  • Programmable Range & Resolution
  • Avoid the Jumper selection from TC to RTD conversion
  • Front Key Programming and Configuration
  • Universal Supply 90 to 270V AC
  • 15A Relay output
  • Selectable On Off/Time proportional/Auto tune PID
  • All type of Temperature Sensors with different dimensions are available on request
View Complete Details

Thermocouples

  • Type 'K' :
  • 0 - +1100°C Type 'J'
  • : 0 - +700°C
  • Type 'N' :
  • 0 - +1100°C Type 'R'
  • : 0 - +1600°C
  • Type 'S' :
  • 0 - +1600°C Type 'E'
  • : 0 - +800°C
  • Type 'B' :
  • +200 - +1700°C Type 'T'
  • : -185 - +300°C

Thermocouples are the most common temperature-sensing device. They can be made in very tough designs. They are very simple in operation and measure temperature at a point. Over different types they cover from -250C to +2500C.

And also we provide wind speed sensor under different models for different environments.

Compensation cables are indispensable for precise temperature measurement, they serve as extension leads from the thermocouple sensor to the measuring instrument loop. Compensating cables are made from metallic materials having similar thermoelectric properties as the thermocouple in use.

View Complete Details

Glass Tube Rotameters

Suitable for online installation with flanged or screwed connections with several opations of materials for the wetted parts.
View Complete Details

Orifice Plate

GAYATRI's make Orifice Plate with holding flanges nut bolts and gaskets are called orifice assembly. Flanges generally are of M.S./C.S./304 S.S./316 S.S., nut bolts M.S. Galvanized, Gasket C.A.F. Other construction is possible & will be made against order. Flanges generally are of 4 types a) Weld Neck b) Slip-on c) Carrier Ring d) D & D/2 tapings or pipe run assembly. Pressure tapings are in flange itself in 1st 3 types, while for D & D/2 they are on pipe. Assemblies supplied for 11/2" to 24" Line sizes. Orifice bore calculations as per BS1042 on the basis of your given data is done & bore size is determined & made. Bore calculations are also provided along with instruments or can be sent for approval before manufacturing.

View Complete Details

Pressure Controller

4 Digit 7 Segment LED-1 to 1000 Bar in different ranges0.25% of FS AccuracySelectable any two scales (Bar, Psi, Kgcm2 etc.)14" NTP male for pressure connection230V AC 50Hz SupplyOne set point with relay outputZero adjustment providedSize: 96x96x110 mm
View Complete Details

Glass Tube Rotameter

Suitable for online installation with flanged or screwed connections with several opations of materials for the wetted parts.

View Complete Details

Inclined Manometer

GAYATRI's make acrylic plastic Inclied Tube Manometer are precision instruments in inclined and vertical (Well Type styles for the measurement of static pressure, vacuum or different pressure, recommended where less than 1mm readings are required. Minimum divisions available are 0.5mm, 0.2mm, 0.1mm or as required. Utilize expanded scales for unusual sensitivity for fast, easy reading of low pressures, draft or small differential pressure.

View Complete Details

SINGLE LIMB WELL MANOMETER

GAYATRI's make Single Limb well Type direct reading Manometers are used for precision measurement of pressure, vacuum, differential pressure flow and liquid level measurement. Initially liquid is filled in the well till the scale shows zero but when a positive pressure is being applied on the liquid in the well, causing the level to go down very slightly. Liquid level in the indicating tube has risen substantially giving direct reading from scale in desired units. The single limb well type manometers are accurate & dependable as well as highly versatile for many applications. All Scales are graduated to correct for the drop in the well level.

View Complete Details

DIGIT PROCESS INDICATOR

  • Micro Controller based 24 bit Resolution AD Converter
  • Inputs 20mA, 56mV, 10V
  • User Scalable Display Range from -199999 to +199999 (2 Lakhs counts)
  • Resolution 0.00001 to 1 (user selectable)
  • Programmable input range settingeg: 4-20mA, 0-5V, 0-40mV, -10 to 20mV etc.)
  • 24 DC Power Supply for Remote transmitter excitation
View Complete Details

Full View Sight Flow Indicator

GAYATRI's full view sight glass is a tubular glass assembled in between two bodies 360 visibility is possible by using tubular glass. Mostly used in low pressure line i.e. 0 to 0 kg/cm2

View Complete Details

MINERAL INSULATED RTD

  • MI RTDs can be bent as required
  • More robust and vibration resistant
  • Single and Dual element
  • 3, 5, 6 and 8mm dia
  • SS316 sheath
  • Lengths upto 10 metres
  • 0 to 400C standard rating
  • Other ranges optional
View Complete Details

TRANSITION JOINT RTD

TRANSITION JOINT RTD
  • Integral cable makes the assembly light and easy to install
  • Easy to use models
  • Standard models for -20 to 250C range; other ranges available
  • SS316 sheath, SS316L optional
  • PTFE insulated and jacketed cables, stainless steel overbraided cables available
  • Supplied with 1 meter cable or in multiples thereof
View Complete Details

Thermal Conductivity

THERMAL CONDUCTIVITY (TCD)

The Series 2000 TCD Analyzers are designed to continuously monitor the concentration, or purity, of a desired gas in a mixture of background gases (i.e., 70-100% H2 in HCs).

View Complete Details

Flame Ionization Detectors

FLAME IONIZATION DECTECTION (FID)

The Series 4000 FID platform is highly flexible. In its most basic configuration - the Model 4020 - Teledyne provides a continuous analysis of the total hydrocarbon (THC)

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Gunasekaran (Gayatri Electronics Instruments and Engineering)
  • 76/G2,C-Block,Rukmani Devi Street Indira Nagar Valasaravakkam, Chennai - 600 087., Tamil Nadu
  • Share us via
  • Call 08068051324 Ext. 231