Post Buy Requirement

Our Products #4672713

Food Radiation Monitor

The RAD IQ FS200 is a food monitor system designed to monitor radiation levels in food sample being contained in a Marinelli beaker.The RAD IQ FS200 consists of a 3x3 inch NaI(Tl) detector and a built-in digital MCA mounted inside of 20 mm thick cylindrical lead shield. The affordable NaI based system satisfies most requirements and legislations for food industry.

Furthermore, the RAD IQ FS200 offers a standard software for complete quantitative and spectroscopic data analysis.

KEY FEATURES

  • 3x3 inch NaI (Tl) detector with built-in MCA.
  • 32 bit RISC ARM Cortex digital MCA with 4096 channel resolution.
  • 20 mm lead shielding (4 shielding except detector insert hole opening).
  • High speed network through USB 2.0 protocol.
  • Accommodate up to 1 liter size of Marinelli beaker.
  • Quantitative and spectroscopic data analysis of food sample.

 
Detector NaI (Tl) 3 x 3 inch MCA 32 bit RISC, ARM® Cortex-M3
*Energy range 20 ~ 2000 keV Max. count rate 150 kcps
Energy res. 7% ± 1% FWHM @ 662 keV 137Cs Data res.  4096 channel
Network USB 2.0(Full-speed) **Shield 20 mm lead shield
Weight  62 Kg Dimensions  234(f) x 428(H) mm
View Complete Details

Personal Alarm

ADR-10 is unique product for the safety and radiation protection of radiation workers with management of real time dose and doserate. ADR-10 is the Personal Alarm Dosimeter made of si-diode detector for easy handling and rapid response for personal safety and reliable accuracy. With alarm function the user can manage personal safety itself. One-button operation - One-hand operation, Dose and doserate threshold set - Alarm function, Reset for accumulated dose - Display current doserate, Apply automatic unit - LCD back ground illumination
View Complete Details

Radiation Detection Backpack

The RAD IQ BP 100 is designed to meet the requirements for covert search, detection, and identification with high sensitivity. The system is ideal for Homeland Security, First Responder, and Radiological survey applications.

The Backpack unit includes a 3x3 inch NaI(Tl) detector and two 2" diameter by 15" long neutron detection tubes (BF3 or He3). The standard configuration places the detector and electronics in a water and shock resistant reinforced case fitted with a backpack harness. Other configurations areavailable according to specific requirements.

Data acquisition is provided via Blue-Tooth to the PAD unit. The standard PAD unit is the Samsung Galaxy Note. The PAD display provides the user with easy to read information providing assessment of current radiological levels including personal safety and radionuclide identification. Upon completion of a survey the data is downloaded from the PAD unit to the PC. The optional GPS unit provides the necessary data for radiation mapping.

KEY FEATURES

Gamma-ray Spectroscopy for Specific Nuclide Identification

Neutron Detection

Bluetooth Communication to PAD unit for Covert Operation

Up to 24 hour operation on a single battery charge

Automatic System Calibration and Stabilisation

Database protocol for log files and alarm events

Water and Shock Resistant

Small, Convenient, Form Factor and light weight

APPLICATIONS

Homeland Security

Emergency Responder

Radiological Area Mapping

Geological Radiation Survey

Safeguard and nuclear security

View Complete Details

Optical Fiber

We have available Plastic optical fibers for the research community. We can supply fibers of all makes. These fibers can be used for probing as well as detection. Custom enquiries are welcome. We can supply the optical fiber with a variety of polishing requirements including optically polished.

Geebee can also supply plastic optical fiber for the telecom industry for communication. Contact us today for your requirement.

View Complete Details

Whole Body Radiation Contamination Monitor

The RAD IQ WBC is a whole body counter especially designed to examine radiation intake of people those who are exposed by radiation.Its open-style design is unique in the industry and make the examination process more convenient to children and pregnant woman. In addition, adjustable detector height feature enables uniform efficiency and optimal measurement regardless of the height of people.
The patent pending segmented and collimated detector technology not only enhances signal to noise ratio at the region of interest on the body but also lightens shielding requirement that makes the system to maintain its light weight and openness.Most of all, the light weight and small foot-print feature has great advantage in installing the RAD IQ WBC system in small space including a vehicle.

FEATURES

Children and pregnant woman friendly open designSegmented and collimated eight 3x3 inch NaI(Tl) detectorsSmall foot-print and Light weightAdjustable detector height depending on object heightOne minute measurement time for typical operationLaser guided detector positioning

APPLICATION

Radiation intake investigationIn-vivo dosimetryReactor personnel safety

Detector Segmented and collimated NaI(Tl) (3x3 inch, 8ea.)  Shielding 30mm lead (shadow shielding)
Detector FOV coverage 100 x 100 cm Detector travel length 40 cm
Foot print 100 x 100 cm (200 cm height) Weight Total: 1,300 kg
Heaviest item: 33 kg
Typical MDA 150 Bq (Cs134), 
200 Bq (Cs137)
Power 110 - 220 V AC (50 or 60 Hz)
Energy range 200 - 2,000 keV Energy resolution < 9% @ 662 keV (Cs137)
Operating Temp. Requirement Stable within ± 5 °C Options Calibration phantom


View Complete Details

Spectroscopic Radiation Monitoring System

The RAD IQ S100 is an advanced spectroscopic portal (ASP) system intended for portal, vehicle, pedestrian orluggage monitoring.An affordable solution to bulky and expensive portal monitors, the RAD IQ S100 features an integrated digitalmulti - channel analyzer (MCA) for radioisotope identification.An intelligent isotope identification algorithm makes it possible to identify radioisotopes of extremely low radioactivity.The RAD IQ S100 includes an Ethernet interface that provides remote, real-time, and 24/7 monitoring.When a radiation event occurs, local alarms are triggered, the date and time are recorded, the location of the area isnoted, the event is photographed, the radioactive material is identified, a isotope spectrum is recorded, and remotenotification can occur.Furthermore, its flexible mounting feature offers effortless installation at any places such as doorways, driveways orconveyor systems.

KEY FEATURES

Intelligent isotope identification algorithm.Remote, real-time and 24/7 monitoring.Multiple units can be managed from central control station.External visual/acoustic alarm unit.PoE (Power of Ethernet) and integrated digital MCA.Automatic system calibration.Database log files for alarm events.Effortless installation with brackets or tripods.Lead collimation with adjustable FOV angle for effective background suppression.

APPLICATIONS

Vehicle monitoringPedestrian monitoringShipping/receiving dock monitoringSecurity check point at airportLuggage inspection

Detector NaI(Tl) 2 x 2 or 2 x 3 inch Operating temp. 5°F(-15°C) to 122°F(50°C)
Energy range 20 ~ 2000 keV Relay output  12 V on/off (user programmable)
MCA 32 bit RISC, ARM® Cortex-M3 Collimation 10 mm or 20 mm lead
Energy res. 7% ± 1% FWHM @ 662 keV Cs137 Power PoE or 12 VDC(switchable)
Netwrok RJ-45 Ethernet Minimum dose
for isotope ID 3)
24 x 10-12 Gy
Weight  12.5 Kg or 23 Kg Dimensions 190(W) x 245(H) x 570(D) mm
Calibration Automatic or Manual(Cs137) Optional Items Network cam,
External acoustic & visual alarm


View Complete Details

MCP DETECTORS

Geebee International can provide 25 mm and 40 mm focussed image intensifiers along with a range of open detector systems. With this a two dimensional image of electrons, X ray, UV radiation and ionized particles is possible. They are suuitable for the 10 eV - 1000 eV range.
Their applications include electron detection, X Ray detection, UV, TOF measurements, Particle beam adjustments and mass spectrometry.
The MCP can be coated with CuI, MgO, MgF2, CsI

View Complete Details

Image Intensifiers

These intensifiers can be used under low light conditions and for photon counting. Further they are useful in UV imaging and and for low light imaging.The image intensifiers are offered with 25 or 40 mm active diameter. Various screens such as P43, P46 or P47 can be used along with a glass or fiber optic window. we can provide an internal or seperate power supply

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Sahil Pershad (Geebee International)
  • 12 - A, Lane W - 16, Sainik Farms, New Delhi - 110 062 India - 110062
  • Share us via
  • Call 08069247214 Ext. 853
Browse Our Products list of Geebee International Delhi, Delhi
Post Buy Requirement

Our Products #4672713

Food Radiation Monitor

The RAD IQ FS200 is a food monitor system designed to monitor radiation levels in food sample being contained in a Marinelli beaker.The RAD IQ FS200 consists of a 3x3 inch NaI(Tl) detector and a built-in digital MCA mounted inside of 20 mm thick cylindrical lead shield. The affordable NaI based system satisfies most requirements and legislations for food industry.

Furthermore, the RAD IQ FS200 offers a standard software for complete quantitative and spectroscopic data analysis.

KEY FEATURES

  • 3x3 inch NaI (Tl) detector with built-in MCA.
  • 32 bit RISC ARM Cortex digital MCA with 4096 channel resolution.
  • 20 mm lead shielding (4 shielding except detector insert hole opening).
  • High speed network through USB 2.0 protocol.
  • Accommodate up to 1 liter size of Marinelli beaker.
  • Quantitative and spectroscopic data analysis of food sample.

 
Detector NaI (Tl) 3 x 3 inch MCA 32 bit RISC, ARM® Cortex-M3
*Energy range 20 ~ 2000 keV Max. count rate 150 kcps
Energy res. 7% ± 1% FWHM @ 662 keV 137Cs Data res.  4096 channel
Network USB 2.0(Full-speed) **Shield 20 mm lead shield
Weight  62 Kg Dimensions  234(f) x 428(H) mm
View Complete Details

Personal Alarm

ADR-10 is unique product for the safety and radiation protection of radiation workers with management of real time dose and doserate. ADR-10 is the Personal Alarm Dosimeter made of si-diode detector for easy handling and rapid response for personal safety and reliable accuracy. With alarm function the user can manage personal safety itself. One-button operation - One-hand operation, Dose and doserate threshold set - Alarm function, Reset for accumulated dose - Display current doserate, Apply automatic unit - LCD back ground illumination
View Complete Details

Radiation Detection Backpack

The RAD IQ BP 100 is designed to meet the requirements for covert search, detection, and identification with high sensitivity. The system is ideal for Homeland Security, First Responder, and Radiological survey applications.

The Backpack unit includes a 3x3 inch NaI(Tl) detector and two 2" diameter by 15" long neutron detection tubes (BF3 or He3). The standard configuration places the detector and electronics in a water and shock resistant reinforced case fitted with a backpack harness. Other configurations areavailable according to specific requirements.

Data acquisition is provided via Blue-Tooth to the PAD unit. The standard PAD unit is the Samsung Galaxy Note. The PAD display provides the user with easy to read information providing assessment of current radiological levels including personal safety and radionuclide identification. Upon completion of a survey the data is downloaded from the PAD unit to the PC. The optional GPS unit provides the necessary data for radiation mapping.

KEY FEATURES

Gamma-ray Spectroscopy for Specific Nuclide Identification

Neutron Detection

Bluetooth Communication to PAD unit for Covert Operation

Up to 24 hour operation on a single battery charge

Automatic System Calibration and Stabilisation

Database protocol for log files and alarm events

Water and Shock Resistant

Small, Convenient, Form Factor and light weight

APPLICATIONS

Homeland Security

Emergency Responder

Radiological Area Mapping

Geological Radiation Survey

Safeguard and nuclear security

View Complete Details

Optical Fiber

We have available Plastic optical fibers for the research community. We can supply fibers of all makes. These fibers can be used for probing as well as detection. Custom enquiries are welcome. We can supply the optical fiber with a variety of polishing requirements including optically polished.

Geebee can also supply plastic optical fiber for the telecom industry for communication. Contact us today for your requirement.

View Complete Details

Whole Body Radiation Contamination Monitor

The RAD IQ WBC is a whole body counter especially designed to examine radiation intake of people those who are exposed by radiation.Its open-style design is unique in the industry and make the examination process more convenient to children and pregnant woman. In addition, adjustable detector height feature enables uniform efficiency and optimal measurement regardless of the height of people.
The patent pending segmented and collimated detector technology not only enhances signal to noise ratio at the region of interest on the body but also lightens shielding requirement that makes the system to maintain its light weight and openness.Most of all, the light weight and small foot-print feature has great advantage in installing the RAD IQ WBC system in small space including a vehicle.

FEATURES

Children and pregnant woman friendly open designSegmented and collimated eight 3x3 inch NaI(Tl) detectorsSmall foot-print and Light weightAdjustable detector height depending on object heightOne minute measurement time for typical operationLaser guided detector positioning

APPLICATION

Radiation intake investigationIn-vivo dosimetryReactor personnel safety

Detector Segmented and collimated NaI(Tl) (3x3 inch, 8ea.)  Shielding 30mm lead (shadow shielding)
Detector FOV coverage 100 x 100 cm Detector travel length 40 cm
Foot print 100 x 100 cm (200 cm height) Weight Total: 1,300 kg
Heaviest item: 33 kg
Typical MDA 150 Bq (Cs134), 
200 Bq (Cs137)
Power 110 - 220 V AC (50 or 60 Hz)
Energy range 200 - 2,000 keV Energy resolution < 9% @ 662 keV (Cs137)
Operating Temp. Requirement Stable within ± 5 °C Options Calibration phantom


View Complete Details

Spectroscopic Radiation Monitoring System

The RAD IQ S100 is an advanced spectroscopic portal (ASP) system intended for portal, vehicle, pedestrian orluggage monitoring.An affordable solution to bulky and expensive portal monitors, the RAD IQ S100 features an integrated digitalmulti - channel analyzer (MCA) for radioisotope identification.An intelligent isotope identification algorithm makes it possible to identify radioisotopes of extremely low radioactivity.The RAD IQ S100 includes an Ethernet interface that provides remote, real-time, and 24/7 monitoring.When a radiation event occurs, local alarms are triggered, the date and time are recorded, the location of the area isnoted, the event is photographed, the radioactive material is identified, a isotope spectrum is recorded, and remotenotification can occur.Furthermore, its flexible mounting feature offers effortless installation at any places such as doorways, driveways orconveyor systems.

KEY FEATURES

Intelligent isotope identification algorithm.Remote, real-time and 24/7 monitoring.Multiple units can be managed from central control station.External visual/acoustic alarm unit.PoE (Power of Ethernet) and integrated digital MCA.Automatic system calibration.Database log files for alarm events.Effortless installation with brackets or tripods.Lead collimation with adjustable FOV angle for effective background suppression.

APPLICATIONS

Vehicle monitoringPedestrian monitoringShipping/receiving dock monitoringSecurity check point at airportLuggage inspection

Detector NaI(Tl) 2 x 2 or 2 x 3 inch Operating temp. 5°F(-15°C) to 122°F(50°C)
Energy range 20 ~ 2000 keV Relay output  12 V on/off (user programmable)
MCA 32 bit RISC, ARM® Cortex-M3 Collimation 10 mm or 20 mm lead
Energy res. 7% ± 1% FWHM @ 662 keV Cs137 Power PoE or 12 VDC(switchable)
Netwrok RJ-45 Ethernet Minimum dose
for isotope ID 3)
24 x 10-12 Gy
Weight  12.5 Kg or 23 Kg Dimensions 190(W) x 245(H) x 570(D) mm
Calibration Automatic or Manual(Cs137) Optional Items Network cam,
External acoustic & visual alarm


View Complete Details

MCP DETECTORS

Geebee International can provide 25 mm and 40 mm focussed image intensifiers along with a range of open detector systems. With this a two dimensional image of electrons, X ray, UV radiation and ionized particles is possible. They are suuitable for the 10 eV - 1000 eV range.
Their applications include electron detection, X Ray detection, UV, TOF measurements, Particle beam adjustments and mass spectrometry.
The MCP can be coated with CuI, MgO, MgF2, CsI

View Complete Details

Image Intensifiers

These intensifiers can be used under low light conditions and for photon counting. Further they are useful in UV imaging and and for low light imaging.The image intensifiers are offered with 25 or 40 mm active diameter. Various screens such as P43, P46 or P47 can be used along with a glass or fiber optic window. we can provide an internal or seperate power supply