Our Product / Services
=> Stability and High Accuracy Output=> External Span & Zero adjustment=> Low Internal consumption=> Compact size=> Optional : multiple Output
FEATURES
=> Consistent reliability with high accuracy=> Low cost=> Time Delay user settable (4 Ranges)=> LED indication for Power & Relay status=> Compact size=> ON Delay / OFF Delay modes of operations
=> State of Art Microcontroller Based Design.=> Suitable for 1 Phase & 3 phase measurement=> 2 Solid state Relay Out Put configurable for cutoff setting of any Parameter to give Alarm=> Rugged portable casing=> Clamp on CT's=> Programmable CT & PT Ratio.=> True RMS measurement.=> Auto Scrolling Facility.=> Password protection=> EEprom retains Energy Parameters on power fail.=> Monitors Import & Export Energy.=> Computer Interface ( RS 485) optically isolated=> Inbuilt Data Logger for storing all Parameters-with Date & Time stamp for long duration-Audit without manual intervention / operation.
=> State of Art Microcontroller Based Design.=> Suitable for 1 Phase & 3 phase measurement=> 2 Solid state Relay Out Put configurable for cutoff setting of any Parameter to give Alarm=> Rugged portable casing=> Clamp on CT's=> Programmable CT & PT Ratio.=> True RMS measurement.=> Auto Scrolling Facility.=> Password protection=> EEprom retains Energy Parameters on power fail.=> Monitors Import & Export Energy.=> Computer Interface ( RS 485) optically isolated=> Inbuilt Data Logger for storing all Parameters-with Date & Time stamp for long duration-Audit without manual intervention / operation.
Volts | : | L – L, L – N ( Per Phase & Avg.) |
Amps | : | Per Phase & summation |
Frequency | : | System |
Power Factor | : | Per Phase & Avg |
KW | : | Per Phase & Summation |
KVA | : | Per Phase & Summation |
KVAr | : | Per Phase & Summation |
KWh | : | Import, Export & Summation |
KVArh | : | Capacitive & Inductive |
KVAh | : | Total |
THD | : | Volts & Amps |
Max. Demand | : | KVA / KW |
System | : | 3 Phase 4 Wire / 3 Phase 3 Wire | |||||||||||||||||||||||||||
Aux. Supply | : | 230V /110VAC 50 Hz (-20% +15%) | |||||||||||||||||||||||||||
Burden on Aux. | : | ||||||||||||||||||||||||||||
Voltage Input | : | 110 / 415 / 440 VAC ( L – L )500Vmax | |||||||||||||||||||||||||||
Current Input | : | 1 Amps / 5 Amps | |||||||||||||||||||||||||||
Burden on CT | : | < 0.2 VA | |||||||||||||||||||||||||||
Communication | : | RS 485 ( Modbus – RTU Protocol ) | |||||||||||||||||||||||||||
Temp | : | 0 – 55°C | |||||||||||||||||||||||||||
Humidity | : | < 90% RH ( non condensing ) | |||||||||||||||||||||||||||
Accuracy | : |
|
|||||||||||||||||||||||||||
Dimension | : | 455 x 360 x 150 mm ( L x B x H ) |
=> High quality material, flame retarding and self extinguishing.
=> Apertures accepting a wide range of busbar size
=> Easy Busbar Mounting
=> CTs are ultrasonically welded and are unbreakable.
=> Terminals are finger proof touch as per IEC class
=> Highly Cost effective
=> Compact in size
=> State of Art Microcontroller Based Design with LCD display=> Auto (using external under voltage relay) / Manual Start option=> Programmable Cranking Period / Number of Start attempts & Rest Period=> Low Lube Oil pressure, High water temperature, Over Speed Protections & many more Protection=> Provision for Remote emergency stop=> Battery Under voltage Indication=> Programmable Over speed Limit with delay to avoid nuisance tripping=> Programmable STOP output (enable when active / disable when active)Monitors charging Alternator
=> Temp. Indication System=> Process Control System=> Temp. Safety System
=> State of Art Microcontroller Based Design.=> Relay Out Put for cutoff / Alarm=> User Programmable Alarm Set Point, Time Delay & CT Ratio.=> True RMS measurement.=> Auto Scrolling Facility.=> Password protection=> Bar Graph Indication for Load=> ALARM / TRIP:-UNDER VOLTAGE-OVER VOLTAGE-OVER LOAD-PHASE SEQUENCE REVERSAL-PHASE FAILURE=> Consistent reliability with high accuracy=> Low cost=> Thermocouple / RTD / DCV / DC mA=> Compact size
APPLICATION=> PLC Panels=> Automation=> Feeder / motor=> Generator=> Transformer=> Electrical Dist.
=> State of Art Microcontroller Based Design.=> Built in Solid state selector switch for phase selection=> Super bright LED display for crystal clear long distance viewing=> CT ratios user Programmable through front Key Pad.=> RPM=> Run Hour Indication
E P U=> State of Art Microcontroller Based Design.=> Auto (using external under voltage relay) / Manual Start option=> Programmable Cranking Period / Number of Startattempts & Rest Period=> Low Lube Oil pressure, High water temp., Over Speed Protections=> Provision for Remote emergency stop=> Battery Under voltage Indication=> Programmable Over speed Limit with delay to avoid nuisance tripping
=> State of Art Microcontroller Based Design with LCD display=> Auto (using external under voltage relay) / Manual Start option=> Programmable Cranking Period / Number of Start attempts & Rest Period=> Low Lube Oil pressure, High water temperature, Over Speed Protections & many more Protection=> Provision for Remote emergency stop=> Battery Under voltage Indication=> Programmable Over speed Limit with delay to avoid nuisance tripping=> Programmable STOP output (enable when active / disable when active)Monitors charging Alternator
=> State of Art Microcontroller Based Design.=> Auto (using external under voltage relay) / Manual Start option=> Programmable Cranking Period / Number of Start attempts & Rest Period=> Low Lube Oil pressure, High water temperature, Over Speed Protections=> Provision for Remote emergency stop=> Battery Under voltage Indication=> Programmable Over speed Limit with delay to avoid nuisance tripping
=> Temp. Indication System=> Process Control System=> Temp. Safety System
MODELS=> GIPS 100T - Temperature Indicator=> GIPS 100TO - Temperature Indicator with On / OFF control=> GIPS 100TP - Temperature Indicator with proportional control=> GIPS 100TC - Temperature Indicator with 2 Line display, 2 Relay O/P (alarm &control) & 4-20mA O/P
Aux. Supply | : | 230V/110VAC50Hz(-20% +15%) | ||||||||||||||||||||
Burden on Aux | : | < 3 VA | ||||||||||||||||||||
Input | : | Pt100/J,K,R,S | ||||||||||||||||||||
Display | : | 4 Digit (Size : 0.56″ / 14.2mm) | ||||||||||||||||||||
Resolution | : | 0.1°C / 1°C for Pt100 & 1°C for thermocouple | ||||||||||||||||||||
Range | : | 0 – 200°C | ||||||||||||||||||||
Humidity | : | < 90% RH ( non condensing) | ||||||||||||||||||||
Accuracy | : | Classl.0 | ||||||||||||||||||||
Operating Temp. | : | 0 – 55°C | ||||||||||||||||||||
Range | : | PT 100 -70°C to 500°C J 0 – 750°C K 0-1200°C R 0-1750°C S 0-1750°C |
||||||||||||||||||||
Dimension | : |
|
||||||||||||||||||||
Sensor | : | Pt100 1) PTS-01 : Industrial Head with Dia : 6.0 mm & L :300 mm 2) PTS-02 : Industrial Head with Dia : 8.0 mm & L :300 mm 3) PTS-03 : With Wire Length : 3.0 Meters |
||||||||||||||||||||
Note | : | Length of PTS-01 & PTS-02 can be increased / decreased as per customer requirement. |
FEATURES
=> State of Art Microcontroller Based Design.=> Relay Out Put for cutoff / Alarm=> User Programmable Alarm Set Point, Time Delay & CT Ratio.=> True RMS measurement.=> Auto Scrolling Facility.=> Password protection=> Bar Graph Indication for Load=> ALARM / TRIP:-UNDER VOLTAGE-OVER VOLTAGE-OVER LOAD-PHASE SEQUENCE REVERSAL-PHASE FAILURE=> Consistent reliability with high accuracy=> Low cost=> Thermocouple / RTD / DCV / DC mA=> Compact size
APPLICATION=> PLC Panels=> Automation=> Feeder / motor=> Generator=> Transformer=> Electrical Dist.
Aux. Supply | 230 /110 VAC 50/60Hz (-20%+15%) |
Burden on Aux. | < 3 VA |
Range | PT100 -70 C to 500 C |
J 0 – 750 C | |
K 0-1200 C | |
R 0-1750 C | |
S 0-1750 C | |
Signal Input | 0-10 VDC, 0-20mA |
Resolution | Temperature Input : 1° C Signal Input : 0.001, 0.01, 0.1 & 1 |
Temp | 20°C to +55°C |
Humidity | < 95% RH ( non condensing) |
Dimension | 96x96x48 mm(LxWxD) |
96x48x58 mm(LxWxD) | |
Weight | 300 gms |
=> State of Art Microcontroller Based Design.=> Built in Solid state selector switch for phase selection=> Super bright LED display for crystal clear long distance viewing=> CT ratios user Programmable through front Key Pad.=> RPM=> Run Hour Indication
E P U=> State of Art Microcontroller Based Design.=> Auto (using external under voltage relay) / Manual Start option=> Programmable Cranking Period / Number of Startattempts & Rest Period=> Low Lube Oil pressure, High water temp., Over Speed Protections=> Provision for Remote emergency stop=> Battery Under voltage Indication=> Programmable Over speed Limit with delay to avoid nuisance tripping
=> State of Art Microcontroller Based Design with LCD display=> Auto (using external under voltage relay) / Manual Start option=> Programmable Cranking Period / Number of Start attempts & Rest Period=> Low Lube Oil pressure, High water temperature, Over Speed Protections &=> many more Protection=> Provision for Remote emergency stop=> Battery Under voltage Indication=> Programmable Over speed Limit with delay to avoid nuisance tripping=> Programmable STOP output (enable when active / disable when active)=> Monitors charging Alternator