Our Products
Suitable Industries for Application of Visible Spectrophotometer :
Specifications :
Wavelength Range340 to 900 nm Wavelength Resolution1 nm Wavelength Accuracy±1.5 nm Measurement Modes Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, °f, °e, ppb, meq/L, μg/L, PCU, P fund, pH, dKH, °dH, meq/kg or no measurement unit)Wavelength Selection automatic, based on the selected method (editable for user methods only)Light Source tungsten halogen lamp Optical System split beam sample and reference light detectors Wavelength Calibration Internal, automatic at power-on, visual feedback Stray Light<0.1 % T at 340 nm with NaNO2Spectral bandwidth5 nm (full width at half maximum)Sample Cell16 mm round, 22 mm round, 13 mm vial, 10 mm square, 50 mm rectangular (with automatic detection)Programs (Factory/User)Up to 150 factory (85 pre-loaded); up to 100 user developed Data Points Stored Up to 9999 measured values Export Capability.csv file format, .pdf file format Connectivity(1) USB - A (mass storage host); (1) USB - B (mass storage device)Battery Type / Life3000 measurements or 8 hours Power Supply15 VDC power adapter; 10.8 VDC Li-Ion rechargeable batteryEnvironment0 to 50 °C (32 to 122 °F); 0 to 95% RHDimensions155 x 205 x 322 mmWeight3 kg (6.6 lbs)Ordering InformationHI-801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.
Details :
GroLine Cleaning Solution
Maintaining a clean pH electrode is vital for not only in getting an accurate pH measurement but also ones that are drift free. Any coating to the sensitive glass bulb or clogging of the junction will impede the electrical circuit resulting in erratic and misleading readings. GroLine cleaning solution ensures the maximum performance from the pH electrode to provide readings that you can depend on.
GroLine Storage Solution
All glass pH electrodes need to be stored properly to guarantee an accurate calibration and to protect the pH electrode from premature failure. A few drops of storage solution will maintain the hydrated layer on the glass bulb and prevent the reference junction and electrolyte from drying out. GroLine storage solutions are specifically formulated to accomplish the task and maximize the life of the pH electrode.
Right Size, Right Price
GroLine calibration cleaning and storage solution is available in convenient 230 ml bottle size.
Quick Cal Dual-Purpose Calibration Solution
With GroLine Quick Cal solution only one solution is needed to calibrate both pH and conductivity. This dual-purpose calibration solution is used with compatible meters with the Quick Cal mode or with pH and conductivity meters that calibrate to pH 6.86 and 5.00 mS/cm, respectively.
Supplied with Certificate of Analysis
All GroLine pH and Conductivity/TDS standards in a 230 ml bottle are supplied with a Certificate of Analysis (COA). The COA contains the information regarding the traceability of the solution to NIST traceability standard. Information includes Standard Reference Material (SRM) used for calibration, lot number, and date of production.
Right Size, Right Price
GroLine calibration solution is available in convenient 230 ml bottle size due to the frequency of use. Infrequent use would include users that calibrate and measure on a weekly or monthly basis. With infrequent use it is important that the solution be used within six months of opening the bottle. After that it should be changed out since the measurements will only be as good as the calibration solution, which degrades over time. For added convenience, the Quick-Cal Solution is also available in 20 ml sachets.
Details