Our Products
Specifications :
Technical Specification
Items | Unit | Types | Test Standard | |||||
---|---|---|---|---|---|---|---|---|
Nominal thickness | mm | 0.04 | 0.05 | 0.08 | 0.13 | -- | ||
mil | 1.5 | 2 | 3 | 5 | ||||
Thickness | mm | 0.04±0.004 | 0.05±0.005 | 0.08±0.006 | 0.13±0.01 | GB/T451.3-2002 | ||
Basic Weight | G/m² | 26±3 | 36±3 | 63±4 | 115±8 | GB/T451.2-2002 | ||
Tensile Strength | MD | KN/m | ≥1.6 | ≥2.5 | ≥4.0 | ≥8.5 | GB/T12914-2008 | |
CD | ≥0.8 | ≥1.2 | ≥3.5 | ≥5.0 | ||||
Elongation | MD | % | ≥5.0 | ≥6.0 | ≥7.0 | ≥8.0 | ||
CD | ≥4.5 | ≥5.0 | ≥6.0 | ≥6.0 | ||||
Tear strength | MD | mN | ≥500 | ≥600 | ≥1000 | ≥1500 | GB/T445-2002 | |
CD | ≥600 | ≥800 | ≥1200 | ≥20000 | ||||
Dielectric strength | KV/mm | ≥10 | ≥10 | ≥10 | ≥10 | GB/T1408.1-2006 | ||
Shrinkage |
% | ≤2.0 | ≤2.0 | ≤2.0 | ≤2.0 | 60819-2 2002 |
Features :
Main Parameters
Item | Unit | Value | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness | mm | 0.15 | 0.18 | 0.2 | 0.23 | 0.25 | 0.3 | 0.35 | ||
Thickness Tolerance | mm | ±0.02 | ±0.03 | |||||||
Norminal Grammage | g/squaremeter | 180±25 | 210±30 | 240±30 | 260±35 | 300±40 | 350±50 | 430±50 | ||
Tensile Strength | Lengthwise | Not Bended | N/10mm | >150 | >160 | >180 | >200 | ≥220 | ≥270 | ≥320 |
Bended | >80 | >110 | >130 | >150 | ≥180 | ≥200 | ≥250 | |||
Crosswise | Not Bended | >90 | >110 | >130 | >150 | ≥180 | ≥200 | ≥250 | ||
Bended | >70 | >90 | >110 | ≥130 | ≥150 | ≥170 | ≥200 | |||
Elongation | Lengthwise | Not Bended | % | >10 | ≥12 | |||||
Crosswise | Not Bended | >15 | ≥18 | |||||||
Breakdown Voltage | Not Bended | KV | >7 | ≥10 | ≥11 | ≥12 | ≥13 | ≥15 | ≥20 | |
Bended | >6 | ≥8 | ≥9 | ≥10 | ≥12 | ≥13 | ≥16 | |||
Adhesive Property | Room Temperature | No delamination | ||||||||
180±2°C 10min | No delamination,blister,or adhersive flow | |||||||||
Temperature Index | °C | ≥155 | ||||||||
Storage Life | month | 12 months,room temperature,dry and well-ventilated environment | ||||||||
Remark | This product is produced in accordance with JB/T4061.1-1995 and is tested in accordance with GB/T5591.2-2002 |
Applications : Used in motors & generators As slot insulation / Closure, phase insulation/overhang, interphase insulation. In Dry Type Transformers As layer insulation for coils. For choke coils, conductor & shaped components.
Scope :
Property : Excellent heat resistance, dielectric property and mechanical strength, good cutting and overhead resistance, high stiffness good compatibility with insulation varnish.
Purpose : DMD Paper is mainly used as a slot liner, slot closure and phase insulation in the production of low voltage motors. Besides this NMN is used as interlayer insulation in transformers and other electrical machines and appliances.
Technical Specification
Properties | Unit | Values | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness | mm | 0.15 | 0.18 | 0.2 | 0.23 | 0.25 | 0.3 | 0.35 | ||
Thickness Tolerance | mm | +-0.02 | +-0.03 | +-0.04 | ||||||
Nominal Grammage | g/ | 180+-25 | 210+-30 | 240+-30 | 260+-35 | 300+-40 | 350+-50 | 430+-50 | ||
Tensile Strength | MD | No Bending | N/10 | 150 | 160 | 180 | 200 | 220 | 270 | 320 |
After Bending | mm | 80 | 110 | 130 | 150 | 180 | 200 | 260 | ||
TD | No Bending | 90 | 110 | 130 | 150 | 180 | 200 | 250 | ||
After Bending | 70 | 90 | 110 | 130 | 150 | 170 | 200 |
Advantages :
Application : Used in Motors & Generators: As slot insulation / Closure, phase insulation/overhang, interphase insulation. In Dry Type Transformers: As layer insulation for coils. For choke coils, conductor & shaped components
Advantages :