Post Buy Requirement
HP
Delhi, India
Add Review

Transformers #5931526

Isolation Transformer

ServottamIsolation Transformer is used to transfer electrical power from a source of alternating current (AC) power to some equipment or device while isolating the powered device from the power source, usually for safety reasons. Servottam Isolation transformer provides galvanic isolation and are used to protect against electric shock, to suppress electrical noise in sensitive devices, or to transfer power between two circuits which must not be connected. A transformer sold for isolation is often built with special insulation between primary and secondary, and is specified to withstand a high voltage between windings.


Servottam Isolation Transformers block transmission of the DC component in signals from one circuit to the other, but allow AC components in signals to pass. Transformers that have a ratio of 1 to 1 between the primary and secondary windings are often used to protect secondary circuits and individuals from electrical shocks between energized conductors and earth ground. Suitably designed isolation transformers block interference caused by ground loops. Isolation transformers with electrostatic shields are used for power supplies for sensitive equipment such as Online UPS, computers, medical devices, or laboratory instruments, automotive components machines, imported machines etc.


Servottam Isolation Transformer Terminology
Sometimes the term is used to emphasize that a device is not an autotransformer whose primary and secondary circuits are connected. Power transformers with specified insulation between primary and secondary are not usually described only as "isolation transformers" unless this is their primary function. Only transformers whose primary purpose is to isolate circuits are routinely described as isolation transformers.


Servottam Isolation Transformer Operation
Servottam Isolation transformers are designed with attention to capacitive coupling between the two windings. The capacitance between primary and secondary windings would also couple AC current from the primary to the secondary. A grounded Faraday shield between the primary and the secondary greatly reduces the coupling of common-mode noise.

View Complete Details

Auto Transformer

ServottamAutotransformer is an electrical transformer with only one winding. The "auto" prefix refers to the single coil acting on itself and not to any kind of automatic mechanism. In an autotransformer, portions of the same winding act as both the primary and secondary sides of the transformer. In contrast, an ordinary transformer has separate primary and secondary windings which are not electrically connected.


The winding has at least three taps where electrical connections are made. Since part of the winding does "double duty", auto transformers have the advantages of often being smaller, lighter, and cheaper than typical dual-winding transformers, but the disadvantage of not providing electrical isolation between primary and secondary circuits. Other advantages of auto transformers include lower leakage reactance, lower losses, lower excitation current, and increased VA rating for a given size and mass.


Servottam Autotransformer are often used to step up or step down voltages in the 110-115-120 V range and voltages in the 220-230-240 V range - for example, providing 110 V or 120 V (with taps) from 230 V input, allowing equipment designed for 100 or 120 V to be used with a 230 V supply. This allows US electrical equipment to be fed from the higher European voltage. Auto transformers can also be used to supply European 230 V appliances from a 100 or 120 V supply in countries outside Europe. In all cases the supply and the autotransformer must be correctly rated to supply the required power.


Auto Transformer Operation


ServottamAuto Transformer has a single winding with two end terminals, and one or more terminals at intermediate tap points, or it is a transformer in which the primary and secondary coils have part of, or all of their turns in common. The primary voltage is applied across two of the terminals, and the secondary voltage taken from two terminals, almost always having one terminal in common with the primary voltage. The primary and secondary circuits therefore have a number of windings turns in common. Since the volts-per-turn is the same in both windings, each develops a voltage in proportion to its number of turns. In an autotransformer part of the current flows directly from the input to the output, and only part is transferred inductively, allowing a smaller, lighter, cheaper core to be used as well as requiring only a single winding. However the voltage and current ratio of auto transformers can be formulated the same as other two-winding transformers:

View Complete Details

Variable Auto Transformer

  • Coil Number Autotransformer
  • Packaging Details Packed with corrugated box and then wooden crate if required by client.
  • Supply Ability 5000 Piece/Pieces per Week
  • Brand Name HCS
  • Coil Structure Toroidal
  • Place of Origin Delhi, India
  • High quality variac or dimmer Copper wound
View Complete Details

Variable Auto Transformer

  • Model Number Air Cooled Variac
  • Variable Auto Transformer 2 Amp to 1000 Amp.
  • Usage Power
  • Lead Time Shipped in 0 days after payment
  • Coil Number Autotransformer
  • Brand Name HCS
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • HCS Power Ventures Pvt. Ltd (HCS Power Ventures Pvt. Ltd)
  • B-252, Kotla Vill., Mayur Vihar Phase-1 Delhi, DL - 110091, India
  • Share us via
Retailer of Transformers from Delhi, Delhi by HCS Power Ventures Pvt. Ltd
Post Buy Requirement
HP
Delhi, India
Add Review

Transformers #5931526

Isolation Transformer

ServottamIsolation Transformer is used to transfer electrical power from a source of alternating current (AC) power to some equipment or device while isolating the powered device from the power source, usually for safety reasons. Servottam Isolation transformer provides galvanic isolation and are used to protect against electric shock, to suppress electrical noise in sensitive devices, or to transfer power between two circuits which must not be connected. A transformer sold for isolation is often built with special insulation between primary and secondary, and is specified to withstand a high voltage between windings.

Servottam Isolation Transformers block transmission of the DC component in signals from one circuit to the other, but allow AC components in signals to pass. Transformers that have a ratio of 1 to 1 between the primary and secondary windings are often used to protect secondary circuits and individuals from electrical shocks between energized conductors and earth ground. Suitably designed isolation transformers block interference caused by ground loops. Isolation transformers with electrostatic shields are used for power supplies for sensitive equipment such as Online UPS, computers, medical devices, or laboratory instruments, automotive components machines, imported machines etc.

Servottam Isolation Transformer TerminologySometimes the term is used to emphasize that a device is not an autotransformer whose primary and secondary circuits are connected. Power transformers with specified insulation between primary and secondary are not usually described only as "isolation transformers" unless this is their primary function. Only transformers whose primary purpose is to isolate circuits are routinely described as isolation transformers.

Servottam Isolation Transformer OperationServottam Isolation transformers are designed with attention to capacitive coupling between the two windings. The capacitance between primary and secondary windings would also couple AC current from the primary to the secondary. A grounded Faraday shield between the primary and the secondary greatly reduces the coupling of common-mode noise.

View Complete Details

Auto Transformer

ServottamAutotransformer is an electrical transformer with only one winding. The "auto" prefix refers to the single coil acting on itself and not to any kind of automatic mechanism. In an autotransformer, portions of the same winding act as both the primary and secondary sides of the transformer. In contrast, an ordinary transformer has separate primary and secondary windings which are not electrically connected.

The winding has at least three taps where electrical connections are made. Since part of the winding does "double duty", auto transformers have the advantages of often being smaller, lighter, and cheaper than typical dual-winding transformers, but the disadvantage of not providing electrical isolation between primary and secondary circuits. Other advantages of auto transformers include lower leakage reactance, lower losses, lower excitation current, and increased VA rating for a given size and mass.

Servottam Autotransformer are often used to step up or step down voltages in the 110-115-120 V range and voltages in the 220-230-240 V range - for example, providing 110 V or 120 V (with taps) from 230 V input, allowing equipment designed for 100 or 120 V to be used with a 230 V supply. This allows US electrical equipment to be fed from the higher European voltage. Auto transformers can also be used to supply European 230 V appliances from a 100 or 120 V supply in countries outside Europe. In all cases the supply and the autotransformer must be correctly rated to supply the required power.

Auto Transformer Operation

ServottamAuto Transformer has a single winding with two end terminals, and one or more terminals at intermediate tap points, or it is a transformer in which the primary and secondary coils have part of, or all of their turns in common. The primary voltage is applied across two of the terminals, and the secondary voltage taken from two terminals, almost always having one terminal in common with the primary voltage. The primary and secondary circuits therefore have a number of windings turns in common. Since the volts-per-turn is the same in both windings, each develops a voltage in proportion to its number of turns. In an autotransformer part of the current flows directly from the input to the output, and only part is transferred inductively, allowing a smaller, lighter, cheaper core to be used as well as requiring only a single winding. However the voltage and current ratio of auto transformers can be formulated the same as other two-winding transformers:

View Complete Details

Variable Auto Transformer

  • Coil Number Autotransformer
  • Packaging Details Packed with corrugated box and then wooden crate if required by client.
  • Supply Ability 5000 Piece/Pieces per Week
  • Brand Name HCS
  • Coil Structure Toroidal
  • Place of Origin Delhi, India
  • High quality variac or dimmer Copper wound
View Complete Details

Variable Auto Transformer

  • Model Number Air Cooled Variac
  • Variable Auto Transformer 2 Amp to 1000 Amp.
  • Usage Power
  • Lead Time Shipped in 0 days after payment
  • Coil Number Autotransformer
  • Brand Name HCS
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us