Our Products
Technical Characteristics
Applications
PTFE is one of the leading dielectric materials used as insulation in high performance wire and cable. PTFE Insulated Cables (Brand Name Hotway PTFE Insulated Cables) has excellent dielectric constants, low dissipation factors, a wide temperature performance range and high frequency stabilities. Our assortment of PTFE Insulated Cables includes Multicore Cable, Hook up Cable, Multi pair Cable and RTD Cable.
Poly Tetra Fluoro Ethylene (PTFE), more commonly known as Teflon, is a linear polymer of Tetrafluoroethylene. The PTFE Insulated Cables chemical structure is essentially equivalent to polyethylene, except that the hydrogen atoms are completely replaced by fluorine atoms. PTFE Insulated Cable, which we offer, has a very unique position in the Plastics industry due to its chemical inertness, UV resistance, heat resistance, excellent electrical properties, and low coefficient of friction over a wider temp. PTFE differs from other fluoropolymers; it is the only one which cannot be fabricated by conventional melt processing techniques.
PTFE Insulated Cables are manufacture as per JSS 51034 (equivalent to us military specification MIL-W-16878) are most suitable for Electrical Panel, Electrical equipment and instruments wiring. We offer the PTFE Insulated Cables that are used in Steel and Power Plants (Thermocouple cable, HR cable, RTD Cable) and Electrical & Electronic Industry. Used majorly for interconnection of equipment and for inter-unit and inter-panel connection, these PTFE Insulated Cables are available in different grades and sizes.
Manufacturing TechniquePTFE insulated wire & cable manufacturing process is not a simple process like PVC cable. in PVC manufacturing. We use extrusion process; PVC granules melt in an extruder in certain heat and cover the conductor in extrusion process. In PTFE first we make the tape from PTFE fine powder by cold extrusion than cut the tape in required width than wrap over the conductor by spiral wrapping system. After wrapping the insulated wire, we cure (sinter) at 380 deg. C by continues running process. After sintering we test the wire in required voltage and pack in coil or spool.
Approvals : PTFE insulated wires & Cable is approved By Ministry of defense, Govt. of India from the body JSS (Joint services specification)
Properties
Availability
Specification
ze AWG | Number of Stands/Dia of Strand | Dia of Cond- uctor (mm) | Cross Secti- onal area mm2 |
ET 250V | ET 600V | EE 1000V | Max Resistance of Conductor OHMS/KM at 20°C |
Current Rating (amps) |
||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
OD of insulation | OD of insulation | OD of insulation | ||||||||||
AWG | (mm) | Min (mm) |
Max (mm) |
Min (mm) |
Max (mm) |
Min (mm) |
Max (mm) |
|||||
32 | 07/01/40 | 7/0.08 | 0.25 | 0.04 | 0.5 | 0.6 | 0.66 | 0.86 | 0.91 | 1.11 | 567 | 0.7 |
30 | 01/30/24 | 1/0.25 | 0.25 | 0.05 | 0.5 | 0.6 | 0.66 | 0.86 | 0.91 | 1.11 | 354 | 1 |
30 | 07/01/38 | 7/0.10 | 0.31 | 0.06 | 0.55 | 0.66 | 0.71 | 0.91 | 0.96 | 1.16 | 330 | 1 |
28 | 01/28/24 | 1/0.32 | 0.32 | 0.08 | 0.58 | 0.68 | 0.73 | 0.93 | 0.99 | 1.19 | 223 | 2.1 |
28 | 07/01/36 | 7/0.13 | 0.38 | 0.09 | 0.63 | 0.73 | 0.78 | 0.99 | 1.04 | 1.24 | 209 | 2.1 |
26 | 01/26/24 | 1/0.40 | 0.4 | 0.13 | 0.66 | 0.76 | 0.81 | 1.01 | 1.06 | 1.27 | 140 | 3 |
26 | 07/01/34 | 7/0.16 | 0.48 | 0.14 | 0.73 | 0.83 | 0.88 | 1.09 | 1.14 | 1.34 | 132 | 3 |
26 | 19/38 | 19/0.10 | 0.51 | 0.15 | 0.73 | 0.83 | 0.88 | 1.09 | 1.14 | 1.34 | 125 | 3 |
24 | 01/24/24 | 1/0.51 | 0.51 | 0.2 | 0.76 | 0.86 | 0.91 | 1.11 | 1.16 | 1.37 | 87 | 4 |
24 | 07/01/32 | 7/0.20 | 0.61 | 0.22 | 0.86 | 0.96 | 1.01 | 1.21 | 1.27 | 1.47 | 82 | 4 |
24 | 19/36 | 19/0.13 | 0.64 | 0.25 | 0.86 | 0.96 | 1.01 | 1.21 | 1.27 | 1.47 | 79 | 4 |
22 | 01/22/24 | 1/0.64 | 0.64 | 0.32 | 0.88 | 1.01 | 1.04 | 1.27 | 1.29 | 1.52 | 55 | 7.3 |
22 | 07/30/24 | 7/0.25 | 0.76 | 0.34 | 1.01 | 1.11 | 1.16 | 1.37 | 1.42 | 1.62 | 52 | 7.3 |
22 | 19/34 | 19/0.16 | 0.81 | 0.38 | 1.01 | 1.11 | 1.16 | 1.37 | 1.42 | 1.52 | 49 | 7.3 |
20 | 01/20/24 | 1/0.81 | 0.81 | 0.52 | 1.06 | 1.16 | 1.21 | 1.42 | 1.47 | 1.67 | 34 | 11 |
20 | 07/28/24 | 7/0.32 | 0.97 | 0.56 | 1.21 | 1.32 | 1.37 | 1.57 | 1.62 | 1.82 | 32 | 11 |
20 | 19/32 | 19/0.20 | 1.02 | 0.6 | 1.21 | 1.32 | 1.37 | 1.57 | 1.62 | 1.82 | 30 | 11 |
18 | 07/26/24 | 7/0.40 | 1.22 | 0.88 | 1.63 | 1.87 | 1.87 | 2.13 | 20 | 16 | ||
18 | 19/30 | 19/0.25 | 1.27 | 0.93 | 1.63 | 1.87 | 1.87 | 2.13 | 18 | 16 | ||
16 | 19/29 | 19/0.29 | 1.45 | 1.25 | 1.85 | 2.2 | 2.1 | 2.41 | 14 | 22 | ||
15 | 19/28 | 19/0.32 | 1.6 | 1.53 | 1.98 | 2.28 | 2.26 | 2.54 | 12 | 26 | ||
14 | 19/27 | 19/0.36 | 1.83 | 1.93 | 2.23 | 2.59 | 2.48 | 2.89 | 9 | 32 | ||
13 | 19/26 | 19/0.40 | 2 | 2.39 | 2.43 | 2.74 | 2.66 | 3.02 | 7 | 35 | ||
12 | 19/25 | 19/0.45 | 2.31 | 3.02 | 2.71 | 3.07 | 2.97 | 3.37 | 5 | 41 | ||
12 | 37/28 | 37/0.32 | 2.26 | 2.98 | 2.66 | 3.02 | 2.92 | 3.32 | 6 | 41 | ||
11 | 19/24 | 19/0.50 | 2.5 | 3.73 | 2.99 | 3.3 | 3.2 | 3.58 | 4 | 45 | ||
10 | 19/22 | 19/0.65 | 3.25 | 6.3 | 3.73 | 4.03 | 3.96 | 4.34 | 2 | 55 | ||
10 | 37/26 | 37/0.4 | 2.82 | 4.65 | 3.22 | 3.58 | 3.47 | 3.88 | 3 | 50 | ||
8 | 133/29 | 133/0.29 | 4.29 | 8.78 | 5.05 | 5.56 | 2 | 75 | ||||
6 | 133/27 | 133/0.36 | 5.41 | 13.54 | 6.42 | 6.93 | 1 | 100 |
Under Floor Heating Mat
These Floor Heaters are designed for a variety of applications. Modern underfloor heating systems use electrical resistance elements (“electric systems”) to heat the floor. This type can be installed as the primary, whole-building heating system or as localized floor heating for thermal comfort. Under floor heating is a form of central heating which achieves indoor climate control for thermal comfort. Floor heating systems are used only for heating and employ non-corrosive, flexible heating elements including cables, pre-formed cable mats. Due to their low profile they can be installed in a thermal mass or directly under floor finishes. Electric systems can also take advantage of time of-use electricity metering and are frequently used as carpet heaters, portable under area rug heaters, under laminate floor heaters, under tile heating, under wood floor heating, and floor warming systems, including under shower floor and seat heating.
Benefits of Electric Underfloor Heating mat
150 Watt/m² Heating Mat
Sl. No. | Part No. | Mat Size | Area Sq. mtr/Feet | Watt. |
---|---|---|---|---|
1 | HTT150/1 | 0.50×2 mtr | 45302 | 150 |
2 | HTT150/1.5 | 0.50x3mtr | 1.5/16 | 225 |
3 | HTT150/2 | 0.50x4mtr | 45344 | 300 |
4 | HTT150/2.5 | 0.50x5mtr | 2.5/27 | 375 |
5 | HTT150/3 | 0.50x6mtr | 12114 | 450 |
6 | HTT150/3.5 | 0.50x7mtr | 3.5/39 | 525 |
7 | HTT150/4 | 0.50x8mtr | 16163 | 600 |
8 | HTT150/4.5 | 0.50x9mtr | 4.5/50 | 675 |
9 | HTT150/5 | 0.50x10mtr | 20210 | 825 |
10 | HTT150/6 | 0.50x12mtr | 24259 | 900 |
11 | HTT150/7 | 0.50x14mtr | 28672 | 1050 |
12 | HTT150/8 | 0.50x16mtr | 33086 | 1200 |
13 | HTT150/9 | 0.50x18mtr | -657192 | 1350 |
14 | HTT150/10 | 0.50x20mtr | -653145 | 1500 |
15 | HTT150/11 | 0.50x22mtr | -649096 | 1650 |
16 | HTT150/12 | 0.50x24mtr | -645048 | 1800 |
165 Watt/m² Heating Mat
Area Sq. | ||||
---|---|---|---|---|
Sl. No. | Part No. | Mat Size | mtr/Feet | Watt. |
1 | HTT165/1 | 0.50×2 mtr | 01-Nov | 165 |
2 | HTT165/1.5 | 0.50x3mtr | 1.5/16 | 250 |
3 | HTT165/2 | 0.50x4mtr | Feb-22 | 330 |
4 | HTT165/2.5 | 0.50x5mtr | 2.5/27 | 410 |
5 | HTT165/3 | 0.50x6mtr | Mar-33 | 495 |
6 | HTT165/3.5 | 0.50x7mtr | 3.5/39 | 578 |
7 | HTT165/4 | 0.50x8mtr | Apr-44 | 660 |
8 | HTT165/4.5 | 0.50x9mtr | 4.5/50 | 743 |
9 | HTT165/5 | 0.50x10mtr | May-55 | 825 |
10 | HTT165/6 | 0.50x12mtr | Jun-66 | 990 |
11 | HTT165/7 | 0.50x14mtr | Jul-78 | 1150 |
12 | HTT165/8 | 0.50x16mtr | Aug-90 | 1320 |
13 | HTT165/9 | 0.50x18mtr | -657192 | 1485 |
14 | HTT165/10 | 0.50x20mtr | -653145 | 1650 |
15 | HTT165/11 | 0.50x22mtr | -649096 | 1800 |
16 | HTT165/12 | 0.50x24mtr | -645048 | 1980 |
Some Best Features Of Heating Tape
Hotway Thermal Technology are generally known for manufacturing of the incredible nature of electric heating tape throughout the globe. Our made supplies are used for major streamlined provisions as they hold numerous different aspects which divide our item’s picture from others in the whole commercial center. We have an enormous notoriety in the worldwide showcase in light of our radiant Floor Heating Tape and Flexible Heating Tape range.
Electric Heating Tape might be utilized on any surface or form which requires quick and effective immediately contact warming. For extensive surface provisions there is the warming cover. Yet the high temperature string remains a down to earth and practical instrument in the lab. Its adaptable outline and high temperature ability furnish a perfect answer for the sum of your hard-to-fit vessels, for example, barrels, measuring utensils, vials and tubing.
We have kept the custom of development in our assembling unit. Our quality measures begin from the starting and run until the closure of the procedure to guarantee the best nature of our item. In the most recent years we have improved the quality of our tapes to build our name as the preeminent player in the fare business of wire and cable industries. These all items are decorously tried by our analyzers soon after the last discharge in the business sector.
They make outlines which are enduring in nature and accompanies a decently completed style. We are ceaselessly endeavoring to enhance the efficiency of our products to serve best characteristics in it. We can furnish such results which can best suits to your every needs. We have the designers who are aware of all the new market patterns. All our staff are eager towards their vocation and they endeavor to fulfill the requirements of our regarded customers.
Applications Of Door Heater
Main Characteristics Of Door Heater
Hotway Thermal Technology offer Door Heater For the purpose of Cold Storage. These are intended to match the requirement of major applications. In refrigeration commercial enterprises vast number of things and nourishment articles are preserved at a below zero temperature to forestall debasement of value. This requires a substantial number of cold rooms having temperature of – 40ºc.
The point when air interacts with inside at the entryway outlines, ice get formed at entryway which generally blocks the entry. Cold Storage Door Heaters are well efficient in performance. Electric Door Heater are PTFE covered adaptable radiator. Cold Storage Door Heater is intended for persistent use to secure discharges against ice development which accelerates blockage. We are a standout amongst the best manufacturers and suppliers of Door Heater Tape.
Applications Of Door Heater
Main Characteristics Of Door Heater
DRAIN HEATERS :-
These Drain Heaters are designed for a variety of applications. In refrigeration processes large number of commodities and food articles are stored at a sub-zero temperature to prevent degradation of quality. This requires a large number of cold rooms having temperature of – 40 o C. when atmospheric air comes in contact with the cold air at door frames; ice is formed at door frames, which jams the doors. Door Heater tapes are fixed in a groove made in the door frames. Door Heaters are PTFE insulated flexible heaters. These Drain Heaters are designed for continuous use to protect drains against ice buildup, which leads to clogging. These Door Heaters can be used on the condensation drain pans, tubes, and troughs of both commercial & domestic refrigerators, air conditioners, Heat Pump Systems and Cold Storage.
Highlights
LPG Cylinder Jacket Heater
Striking Features Of Electric Heating Pad
Our Heating Pad are adaptive in nature and works on 220-250 volts (AC), furthermore is accessible in the diverse sizes to meet the all the demands of clients. It could be effectively wrapped around the parts of the body.
Hotway Thermal Technology company is overseen by the technocrats with long standing knowledge and has the capacity to meet the requesting guidelines given out by the customers. We have earned a brilliant notoriety in the residential markets owing to our dedication to greatness and nature of the items. Because of our diligent work and fore-sights the firm has made wonderful advancement. While doing the excellent business, we have picked up sound experience in this line of business
We own with innovative equipments which helps us in yielding fantastic course of Electric Heating Pad and also guarantees higher productivity. Our base includes advanced plants to produce items with a steadily expanding turnover. We are striving to meet the desires of our customers by designing resourceful plans.
We give tremendous stretch on Research & Development at different levels .Consistent change in the nature of existing items, services and the advancement of new items is an approach matter in our lives up to expectations.
Our firm is specialized in offering superior quality Silicone Wire Cables. These cables are produced using latest technology machineries and best quality resources. These cables are passed through specific parameters to check its quality. We provide our clients with these cables at an economic range along with their varied specifications.
These cables possess some attractive features which are:
Compressor heaters for air conditioner and refrigeration compressors
A crankcase heater is an electrical component in a compressor in an air-conditioning system, heat pump system, or chiller system. The crankcase heater is normally on all the time, even when the unit is not running, though temperature sensors and set points may turn it off when not needed. A crankcase heater’s sole purpose is to prevent refrigerant migration and mixing with crankcase oil when the unit is off, and to prevent condensation of refrigerant in the crankcase of a compressor. The crankcase heater keeps refrigerant at a temperature higher than the coldest part of the system. A crankcase heater generally has the same electrical symbol as a because it converts electricity directly into heat the resistance in the heater coil determines the heat it produces when voltage is applied.
We offer the PTFE Sleeve (Brand Name Hotway PTFE Sleeve), which is available in a wide range of Bore size and wall thickness with high dielectric strength, nonstick and low flammability, and has a wide temperature range (-200 to +280 deg. C). These PTFE Sleeves are mainly used in Computers and Professional Electronics, Radar, Aircraft and Satellite System, Transformers, Industrials heaters, etc.
Why Our PTFE Sleeve?
Heated Door Mats are for outside use and they are outlined with an inward cutoff switch that won't permit the mats to turn on if the surrounding temperature is above 18 degrees Celsius. Actually, when utilizing the mats outside, if the surrounding temperature is above 16 degree Celsius the mats won't turn on.
Heated Door Mat are solid enough to be utilized outside for the duration of the winter, so you can put your warmed entryway tangle outside before the winter begins. Turn it on before snowfall and you will surely get better outcomes. Do keep the mat for a couple of hours after snow has halted, as you may have water spillover. This Moveable Heated Door Mats might be utilized in the majority of the surfaces, incorporating blacktop, cement, stone, and wood decks. Nonetheless, it is ideal not to utilize it on decks made of plastic/composite material and can go about as a protector, and can leave blaze checking or staining. To avert this from happening, attempt to work the mat throughout snow fall hours and not abandon them on to augmented times or spot portions of plywood under the mats to permit higher temperature to be fittingly circulated.
Best Specifications Of Heated Door Mats
We feel proud to introduce ourselves as an affluent provider of Under Carpet Heating Mat. In adherence to predefined industry standards of quality, the offered mat is manufactured using quality-assured raw material and cutting-edge technology. This offered mat is high on demand in the market for its long service life and easy installation. This provided mat is offered by us in various technical specifications according to the client demands.
Features:
These Floor Heaters are designed for a variety of applications. Modern underfloor heating systems use electrical resistance elements (“electric systems”) to heat the floor. This type can be installed as the primary, whole-building heating system or as localized floor heating for thermal comfort.
Under floor heating is a form of central heating which achieves indoor climate control for thermal comfort using conduction, radiation and convection. The terms radiant heating and radiant cooling are commonly used to describe this approach because radiation is responsible for a significant portion of the resulting thermal comfort but this usage is technically correct only when radiation composes more than 50% of the heat exchanged between the floor and the rest of the space.
Floor heating systems are used only for heating and employ non-corrosive, flexible heating elements including cables, pre-formed cable mats. Due to their low profile they can be installed in a thermal mass or directly under floor finishes. Electric systems can also take advantage of time-of-use electricity metering and are frequently used as carpet heaters, portable under area rug heaters, under laminate floor heaters, under tile heating, under wood floor heating, and floor warming systems, including under shower floor and seat heating. Large electric systems also require skilled designers and trades people but this is less so for small floor warming systems. Electric systems use fewer components and are simpler to install and commission than hydronic systems. Some electric systems use line voltage technology while others use low voltage technology. Power consumption of an electric system is not based on voltage but rather wattage output produced by the heating element.
Indoor Air Quality
Underfloor heating can have a positive effect on the quality of indoor air by facilitating the choice of otherwise perceived cold flooring materials such as tile, slate, terrazzo and concrete. These masonry surfaces typically have very low VOC emissions (volatile organic compounds) in comparison to other flooring options. In conjunction with moisture control, floor heating also establishes temperature conditions that are less favorable in supporting mold, bacteria, viruses and dust mites.[24][25] By removing the sensible heating load from the total HVAC (Heating, Ventilating, and Air Conditioning) load, ventilation, filtration and dehumidification of incoming air can be accomplished with dedicated outdoor air systems having less volumetric turnover to mitigate distribution of airborne contaminants. There is recognition from the medical community relating to the benefits of floor heating especially as it relates to allergens.
Safety and Health
Low temperature underfloor heating is embedded in the floor or placed under the floor covering. As such it occupies no wall space and creates no burn hazards, nor is it a hazard for physical injuries due to accidental contact leading to tripping and falling. This has been referenced as a positive feature in healthcare facilities including those serving elderly clients and those with dementia Anecdotally, under similar environmental conditions, heated floors will speed evaporation of wetted floors (showering, cleaning, and spills).
A crankcase heater is an electrical component in a compressor in an air-conditioning system, heat pump system, or chiller system. The crankcase heater is normally on all the time, even when the unit is not running, though temperature sensors and set points may turn it off when not needed. A crankcase heater's sole purpose is to prevent refrigerant migration and mixing with crankcase oil when the unit is off, and to prevent condensation of refrigerant in the crankcase of a compressor. The crankcase heater keeps refrigerant at a temperature higher than the coldest part of the system. A crankcase heater generally has the same electrical symbol as a resistor because it converts electricity directly into heat via electrical resistance. The resistance in the heater coil determines the heat it produces when voltage is applied.
our heating padis adaptive in nature and works on 220-250 volts (ac), furthermore is accessible in the diverse sizes to meet the all the demands of clients. It could be effectively wrapped around the parts of the body.
hotway thermal technology company is overseen by the technocrats with long standing knowledge and has the capacity to meet the requesting guidelines given out by the customers. We have earned a brilliant notoriety in the residential markets owing to our dedication to greatness and nature of the items. Because of our diligent work and fore-sights the firm has made wonderful advancement. While doing the excellent business, we have picked up sound experience in this line of business.
we own with innovativeequipments which helps us in yielding fantastic course of electric heating pad and also guarantees higher productivity. Our base includes advanced plants to produce items with a steadily expanding turnover. We are striving to meet the desires of our customers by designing resourceful plans.
we give tremendous stretch on research & development at different levels .consistent change in the nature of existing items, services and the advancement of new items is an approach matter in our lives up to expectations.
12K/33ohm Resistance Carbon Fiber Heating Cable for Electric Heating Mat Hotway Thermal Technology. is an innovative enterprise which is committed to the research and development , produce and sales of high-efficiency, energy- saving and environmental Friendly electric heating products (Carbon fiber heating cable, High flame retardant high temperature resistance electric cable)
Product Advantage : 1. High energy-efficient 2. Comfortable and healthy: New infrared floor heating, make the temperature uniformity, promote blood circulation, Far infrared radiation without electro radiation, no harm to human body. 3. Easy to install: The carbon fibre heating wire cost a little, and has a long life span, an investment, life-long benefit, low maintenance costs.And etc. Basic Info.
Material Shape Round Wire
Range of Application Flame Retardant
Certification CE, ISO, UKCA
The product can withstand the maximum power: 25Wt/Mtr
The longer the length, the lower the power and the lower the heating temperature. Installation Suggestions: Because of the feature of the carbon fiber cable, this cable cannot be used for a long length. For underfloor heating, we suggest to use 10m per piece, and connect all the pieces in parallel connections. Keep the distance between cables 8 12cm.
Use of Voltage: 5V-220V
Note: the heating line can not overlap each other when used, it can not cross each other, overlapping will cause the hotline local temperature to be higher than the melting point of the protective layer, and will damage the