Our Products
We offer a complete product range of Capacitance Level Transmitter, Float Level Transmitter and Measuring Instruments
“Capacitance Level Transmitter is used in sensing level of liquids. Capacitance Level Transmitter can be used for conductive as well as nonconductive liquids. It is offered with PTFE sleeve for better insulation & to withstand high temperature in conductive tanks the insulated probe acts as one electrode & the tank wall as another electrode, any change in liquid level the dielectric value will change thereby changing the capacitance value proportional to the liquid level. In case of nonconductive tanks, a reference probe is provided as ground electrode.
Highlights
Technical Specification
| Type | 2 Wire (Loop powered), 3 wire (isolated), 4 wire (Isolated) 4-20 mA 0-10 V DC |
|---|---|
| Input | 24V Dc |
| Permissible Load | 500Ω |
| Measuring Rage | 200 mm to 3000 mm in Rigid Probe Upto 15000 mm in Flexile Probe |
| Pressure Max. | 5kg /cm2 |
| Temperature | -25 to 100oC |
| Enclosure | Die Cast aluminium, Weatherproof or Flameproof |
| Resolution | 5mm |
| Accuracy | +0.5 % Fs |
| Mounting | Threaded -½" / 1" / 2" bspm or Npt Flange - 1" /2" Asa/Ansi/Jis/din |
| Mounting | SS 304 or SS 316 |
Float Level Transmitters are ideal for continuous Level monitoring in Water, Diesel, Chemical and Oils for accurate level Measurement. The Output is not affected by liquid type, temperature, Pressure and other physical parameters. The Transmitter is factory calibrated and is ready to use.
ConstructionFloat Level Transmitter consists of non magnetic sealed stem containing series of reed switches and resistor, Float carrying magnet, Mounting adaptor (or flange) and enclosure containing electronics.
Consider our Float Level Transmitters for all your continuous liquidlevel monitoring needs like Water, Diesel, Lube oils, Fuels, Chemicals and Petrochemical liquids.
Here are just few areas where transmitter can be used.
Technical Specification
| Overall Length | 300 mm to 5000mm |
|---|---|
| Measuring Error | ±0.25 % or Span |
| Output Temperature Co-efficient | ±0.007% / oC |
| Resolution | 5mm / 10mm |
| Ambient Temperature | -40oC to 60oC |
| Liquid Temp. Range | -40oC to 120oC |
| Liquid Min. Density | 0.8 gm/cc |
| Max. Pressure | 10 kg/cm2 |
| Protection category | Weather proof Ip66 to IS : 2147 (or) Flame Proof Gr. IIA & IIB to IS : 2148 |
| Terminals | Max. 1.5mm2 Flexible |
| Cable Entry | PG11 for weather Proof ¾" Et for Flame proof (Glands not supplied) |
| Output | 2 wire, 4-20 mA 3 wire, 0-10 V DC RS 485 |
| Process Connection | Threaded Flanged Tri clamp Others |
| Excitation Voltage | 10-30 V DC |
| Loop Resistance | Max. 1200 Ohms |