Post Buy Requirement

Other Products / Services #3864124

IC PRECISEAL

IC PRECISEAL is single component, polymer modified, elastomeric waterproofing coating for concrete and masonry surfaces. It is a single component and only water is to be added during mixing at site. The product can withstand water impermeability against hydrostatic pressure to counter positive as well as negative side water pressure ingress.










The product can be easily applied by brushing or by spray equipment for larger areas. It has a very high tensile adhesion strength, crack bridging capability and is UV resistant. It can be applied both on the exterior and interior surfaces.


IC PRECISEAL complies with the guideline given in EN 14891, ASTM D5385, EN 1348 and DIN 1048.






Features and Benefits





  • IC PRECISEAL being Single component, does not require mixing of two or more components at site, thus ensuring accuracy and proper quality. Only water is to be added before use at site and mixing can be done manually or mechanically with stirrer, resulting in considerable saving of time and labor.

  • Waterproofing coating system for new and existing surfaces.

  • Forms flexible and washable membrane. The membrane coating is breathable, which allows water vapour to escape, diffusing the pressure buildup.

  • Highly effective for Positive & Negative sides of hydrostatic pressure

    • Positive side water Impermeability : 5-7 Bar

    • Negative side water impermeability: 1.5 Bar



  • Effectively seals all existing cracks in the surface. Crack Bridging Capability : 1.5mm.

  • Good resistance against UV and Infrared Rays.

  • Strong adhesion with all Cementitious surfaces, Non-Toxic, hence suitable for all types of water retaining structures.

  • No additional dead load on the structure after application.

  • The surface is ready for any subsequent application within 48 Hrs.

  • Environment friendly coating, no VOC, improving the LEED score of the structure.






Areas of Application



  • Terrace Water proofing.

  • Sloping Roofs and Chajjas.

  • Plastered masonry, External walls.

  • Overhead and underground water tanks.

  • Swimming pools.

  • Toilets & Bathrooms.

  • Basements.

  • Canals & dams etc.









View Complete Details

IC PRECIGROUT Waterproof Cement

IC PRECIGROUT is General Purpose High Strength Cement based grouting material designed to transfer load effectively and safely, ensuring grouting precision and durability of structure. IC PRECIGROUT inhibits corrosion of embedded steel and imparts high initial and ultimate flexural and compressive strength.




IC PRECIGROUT has been carefully developed to optimum performance, even in the toughest applications along with unparalleled ease of application. It provides long life expectancy and maintains the rigid equipment to foundation connections which is necessary to meet demanding installation requirements.


IC PRECIGROUT complies and exceeds the guidelines provided in ASTM C 1107/ C1107M and EN 1504-3 Class R4


IC PRECIGROUT can be used for the following:



  • All kinds of Grouting work

  • Setting Stanchion /turbine base plates

  • Grouting of precision machinery

  • Setting high strength anchor bolts

  • Grouting of precast elements

  • Steel column pads

  • Filling of voids and jacketing applications

  • Plugging of holes in concrete, etc.


It can also be used for general grouting purposes in concrete such as patch repairs, crack filling, honey comb repairs, road repairs, quick fixing of window and door hold fasts, ceramic insulator jointing etc.






Advantages

  • Very high compressive and flexural strength at very short time.

  • High pot life ensuring negligible wastage.

  • Non-shrink grout with controlled positive expansion ensures proper load transfer and durability of structure.

  • High fluid consistency and bleeding resistance.

  • Quickly and easily placed by pouring or pumping.

  • Resists chemical attack, oils, petroleum products, solvents, and mild caustic alkalis.

  • No added chloride or gypsum.

  • No bleeding and segregation at high fluid consistency.

  • Excellent for dynamic and static loading conditions.

  • Free of chlorides and additives, that may lead to corrosion.

  • High drill resistance property.

  • Self-compacting.

  • Product variants available in both Flow-able and Normal Trowel-able consistency.






Method of Application
Surface Preparation





  • Manual/mechanized method can be used for application.

  • Ensure removal of voids within the material applied.

  • Clean the excess material immediately, if any and can reuse within one hour.

  • In case of addition of Aggregates, it is recommended to mix Aggregate at the ratio of 1:1 to IC PRECIGROUT.




View Complete Details

Mixing

Water to Powder Ratio: Water to IC PRECIGROUT


Normal 16% and Flowable 17%



  • Small quantities of grout may be hand-mixed in a concrete mixing pan using triangular trowel or any suitable tool until lump-free homogeneous mass is obtained. For large quantities and continuous pours, mix using a mortar mixer (300 to 600 rpm) or appropriate groutpump.





    • It is advisable to use a mechanical mixer for uniform and thorough mixing which saves time, labor and ensures maximum workability.

    • More time may be required to mix manually, by using the same percentage of water to prepare the mix.

    • IC PRECIGROUT powder is initially mixed with 80-90% of the recommended water ratio for 4-5 minutes in mechanical mixer and thereafter remaining 10% of water is to be added. Mix thoroughly for 2-3 minutes to obtain homogeneous mass.

    • No extra water should be added to the mix.

    • IC PRECIGROUT mixture should be applied within 1 hour of mixing with water.

    • Let the grout stand for 5 minutes and re-mix for 23 minutes to ensure optimum dispersion and lump free paste.






    Method of Application





    • Manual/mechanized method can be used for application.

    • Ensure removal of voids within the material applied.

    • Clean the excess material immediately, if any and can reuse within one hour.

    • In case of addition of Aggregates, it is recommended to mix Aggregate at the ratio of 1:1 to IC PRECIGROUT.








    • Placement













      • The formwork if required, should be of waterproof material and should be placed properly to counter the hydrostatic forces of grout.

      • IC PRECIGROUT is easily placed by pouring or pumping and compaction should be undertaken.

      • Place grout on one side, flowing to opposite and adjacent sides, to avoid entrapment of air. When necessary, provide vent holes.

      • The prepared grout material can be reused within the pot life. Excess material should be cleaned immediately after the application.

      • Ensure that IC PRECIGROUT remain moist at least for 7 days for attaining desired strength.






      Method of Application with Aggregates

      The water requirement in case of IC PRECIGROUT mixed with aggregate will be approximately 8.5-11% depending the mixing ratio and the aggregate quality.


      It is very important to saturate the aggregates completely before mixing it to the Grout. This will ensure that the aggregates will not absorb water from the mix which may reduce the workability. This will also ensure the elimination of higher dust content if any around the aggregates which impairs the physical properties of Grout.


      Precautions

      • Mixing of water with grout must be done homogeneously as per recommended water-powder ratio only.

      • Do not add extra water to maintain flow or workability after the pot life is over.

      • Clean all the tools and tackles and mixer machine after mixing till the grout is not hardened.

      • Ideal temperature to grout is 1035C. Adjust mixing water temperature while grouting IC PRECIGROUT in extreme cold and hot conditions.

      • Open areas should be protected from rain wind and other aggressive climatic conditions for first 24 hours of grouting.

      • In case of IC PRECIGROUT admixed with Aggregates 1:1, not saturated with water, it is very important to do the water correction depending upon the water absorption of the aggregates (it is very important to consider the dust around the aggregates which will also take lot of water while mixing) hence in this it is quite possible that water requirement may rise by 3% to 5% as mentioned for plain grout depending on the water absorption and dust in aggregate.

      • Coarse aggregates if added, must be clean, hard, angular and roughly in cubical shape. Flaky and absorbent (more than 5% water absorption in 24 hour immersion) aggregates are not recommended for use as they deteriorate the quality of the finished application.


      Quality of aggregate plays a major role in strength, durability and workability if mixed in the grout. Judicious selection of aggregate is advisable to obtain desired parameters.


      Cleaning & Safety

      Remove excess material on tools and site using clean water and mechanical scrubbing before it hardens and difficult to dislodge.


      IC PRECIGROUT is non- toxic, however, as with any cementitious material, avoid prolonged contact with skin and dust inhalation.


      Packaging

      IC PRECIGROUT is available in 40 kg packaging.






      Storage & Shelf Life

      Store in a cool and dry place. Ensure that the bags does not burst or tear while handling. There should be a gap of 0.5 m from the walls to the stacks.


      IC PRECIGROUT will remain usable for a period of six months (6 Months) from date of manufacture when stored as per standard recommended conditions.













View Complete Details

Epoxy Grout

Epoxy grout designed to transfer load effectively and safely, ensuring grouting precision and durability of structure.
View Complete Details

Cement Grout

IC PRECIGROUT is General Purpose High Strength Cement based grouting material designed to transfer load effectively and safely, ensuring grouting precision and durability of structure. IC PRECIGROUT inhibits corrosion of embedded steel and imparts high initial and ultimate flexural and compressive strength.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • A.S.NEGI (International Combustion India Limited)
  • 2E/28, Jhandewalan Extension, New Delhi – 110055 - 440016, India
  • Share us via
List of Other Products by International Combustion India Limited from Delhi, Delhi.
Post Buy Requirement

Other Products / Services #3864124

IC PRECISEAL

IC PRECISEAL is single component, polymer modified, elastomeric waterproofing coating for concrete and masonry surfaces. It is a single component and only water is to be added during mixing at site. The product can withstand water impermeability against hydrostatic pressure to counter positive as well as negative side water pressure ingress.

The product can be easily applied by brushing or by spray equipment for larger areas. It has a very high tensile adhesion strength, crack bridging capability and is UV resistant. It can be applied both on the exterior and interior surfaces.

IC PRECISEAL complies with the guideline given in EN 14891, ASTM D5385, EN 1348 and DIN 1048.

Features and Benefits
  • IC PRECISEAL being Single component, does not require mixing of two or more components at site, thus ensuring accuracy and proper quality. Only water is to be added before use at site and mixing can be done manually or mechanically with stirrer, resulting in considerable saving of time and labor.
  • Waterproofing coating system for new and existing surfaces.
  • Forms flexible and washable membrane. The membrane coating is breathable, which allows water vapour to escape, diffusing the pressure buildup.
  • Highly effective for Positive & Negative sides of hydrostatic pressure
    • Positive side water Impermeability : 5-7 Bar
    • Negative side water impermeability: 1.5 Bar
  • Effectively seals all existing cracks in the surface. Crack Bridging Capability : 1.5mm.
  • Good resistance against UV and Infrared Rays.
  • Strong adhesion with all Cementitious surfaces, Non-Toxic, hence suitable for all types of water retaining structures.
  • No additional dead load on the structure after application.
  • The surface is ready for any subsequent application within 48 Hrs.
  • Environment friendly coating, no VOC, improving the LEED score of the structure.
Areas of Application

  • Terrace Water proofing.
  • Sloping Roofs and Chajjas.
  • Plastered masonry, External walls.
  • Overhead and underground water tanks.
  • Swimming pools.
  • Toilets & Bathrooms.
  • Basements.
  • Canals & dams etc.
View Complete Details

IC PRECIGROUT Waterproof Cement

IC PRECIGROUT is General Purpose High Strength Cement based grouting material designed to transfer load effectively and safely, ensuring grouting precision and durability of structure. IC PRECIGROUT inhibits corrosion of embedded steel and imparts high initial and ultimate flexural and compressive strength.

IC PRECIGROUT has been carefully developed to optimum performance, even in the toughest applications along with unparalleled ease of application. It provides long life expectancy and maintains the rigid equipment to foundation connections which is necessary to meet demanding installation requirements.

IC PRECIGROUT complies and exceeds the guidelines provided in ASTM C 1107/ C1107M and EN 1504-3 Class R4

IC PRECIGROUT can be used for the following:

  • All kinds of Grouting work
  • Setting Stanchion /turbine base plates
  • Grouting of precision machinery
  • Setting high strength anchor bolts
  • Grouting of precast elements
  • Steel column pads
  • Filling of voids and jacketing applications
  • Plugging of holes in concrete, etc.

It can also be used for general grouting purposes in concrete such as patch repairs, crack filling, honey comb repairs, road repairs, quick fixing of window and door hold fasts, ceramic insulator jointing etc.

Advantages
  • Very high compressive and flexural strength at very short time.
  • High pot life ensuring negligible wastage.
  • Non-shrink grout with controlled positive expansion ensures proper load transfer and durability of structure.
  • High fluid consistency and bleeding resistance.
  • Quickly and easily placed by pouring or pumping.
  • Resists chemical attack, oils, petroleum products, solvents, and mild caustic alkalis.
  • No added chloride or gypsum.
  • No bleeding and segregation at high fluid consistency.
  • Excellent for dynamic and static loading conditions.
  • Free of chlorides and additives, that may lead to corrosion.
  • High drill resistance property.
  • Self-compacting.
  • Product variants available in both Flow-able and Normal Trowel-able consistency.
Method of ApplicationSurface Preparation
  • Manual/mechanized method can be used for application.
  • Ensure removal of voids within the material applied.
  • Clean the excess material immediately, if any and can reuse within one hour.
  • In case of addition of Aggregates, it is recommended to mix Aggregate at the ratio of 1:1 to IC PRECIGROUT.
View Complete Details

Mixing

Water to Powder Ratio: Water to IC PRECIGROUT

Normal 16% and Flowable 17%

  • Small quantities of grout may be hand-mixed in a concrete mixing pan using triangular trowel or any suitable tool until lump-free homogeneous mass is obtained. For large quantities and continuous pours, mix using a mortar mixer (300 to 600 rpm) or appropriate groutpump.
    • It is advisable to use a mechanical mixer for uniform and thorough mixing which saves time, labor and ensures maximum workability.
    • More time may be required to mix manually, by using the same percentage of water to prepare the mix.
    • IC PRECIGROUT powder is initially mixed with 80-90% of the recommended water ratio for 4-5 minutes in mechanical mixer and thereafter remaining 10% of water is to be added. Mix thoroughly for 2-3 minutes to obtain homogeneous mass.
    • No extra water should be added to the mix.
    • IC PRECIGROUT mixture should be applied within 1 hour of mixing with water.
    • Let the grout stand for 5 minutes and re-mix for 23 minutes to ensure optimum dispersion and lump free paste.
    Method of Application
    • Manual/mechanized method can be used for application.
    • Ensure removal of voids within the material applied.
    • Clean the excess material immediately, if any and can reuse within one hour.
    • In case of addition of Aggregates, it is recommended to mix Aggregate at the ratio of 1:1 to IC PRECIGROUT.
    • Placement
      • The formwork if required, should be of waterproof material and should be placed properly to counter the hydrostatic forces of grout.
      • IC PRECIGROUT is easily placed by pouring or pumping and compaction should be undertaken.
      • Place grout on one side, flowing to opposite and adjacent sides, to avoid entrapment of air. When necessary, provide vent holes.
      • The prepared grout material can be reused within the pot life. Excess material should be cleaned immediately after the application.
      • Ensure that IC PRECIGROUT remain moist at least for 7 days for attaining desired strength.
      Method of Application with Aggregates

      The water requirement in case of IC PRECIGROUT mixed with aggregate will be approximately 8.5-11% depending the mixing ratio and the aggregate quality.

      It is very important to saturate the aggregates completely before mixing it to the Grout. This will ensure that the aggregates will not absorb water from the mix which may reduce the workability. This will also ensure the elimination of higher dust content if any around the aggregates which impairs the physical properties of Grout.

      Precautions
      • Mixing of water with grout must be done homogeneously as per recommended water-powder ratio only.
      • Do not add extra water to maintain flow or workability after the pot life is over.
      • Clean all the tools and tackles and mixer machine after mixing till the grout is not hardened.
      • Ideal temperature to grout is 1035C. Adjust mixing water temperature while grouting IC PRECIGROUT in extreme cold and hot conditions.
      • Open areas should be protected from rain wind and other aggressive climatic conditions for first 24 hours of grouting.
      • In case of IC PRECIGROUT admixed with Aggregates 1:1, not saturated with water, it is very important to do the water correction depending upon the water absorption of the aggregates (it is very important to consider the dust around the aggregates which will also take lot of water while mixing) hence in this it is quite possible that water requirement may rise by 3% to 5% as mentioned for plain grout depending on the water absorption and dust in aggregate.
      • Coarse aggregates if added, must be clean, hard, angular and roughly in cubical shape. Flaky and absorbent (more than 5% water absorption in 24 hour immersion) aggregates are not recommended for use as they deteriorate the quality of the finished application.

      Quality of aggregate plays a major role in strength, durability and workability if mixed in the grout. Judicious selection of aggregate is advisable to obtain desired parameters.

      Cleaning & Safety

      Remove excess material on tools and site using clean water and mechanical scrubbing before it hardens and difficult to dislodge.

      IC PRECIGROUT is non- toxic, however, as with any cementitious material, avoid prolonged contact with skin and dust inhalation.

      Packaging

      IC PRECIGROUT is available in 40 kg packaging.

      Storage & Shelf Life

      Store in a cool and dry place. Ensure that the bags does not burst or tear while handling. There should be a gap of 0.5 m from the walls to the stacks.

      IC PRECIGROUT will remain usable for a period of six months (6 Months) from date of manufacture when stored as per standard recommended conditions.

View Complete Details

Epoxy Grout

Epoxy grout designed to transfer load effectively and safely, ensuring grouting precision and durability of structure.
View Complete Details

Cement Grout

IC PRECIGROUT is General Purpose High Strength Cement based grouting material designed to transfer load effectively and safely, ensuring grouting precision and durability of structure. IC PRECIGROUT inhibits corrosion of embedded steel and imparts high initial and ultimate flexural and compressive strength.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • A.S.NEGI (International Combustion India Limited)
  • 2E/28, Jhandewalan Extension, New Delhi – 110055 - 440016, India
  • Share us via