Our Products
Technical Specifications :
Winning Advantages :
" Ultrasound Scanner Machines will be Sold & Purchased strictly as per the applicable Guidelines of PC & PNDT."
Detects Pathological changes in Vulva, Vagina and the Cervix, filtering Cervix cancer
Technical Specifications
Mode | : | Green, Black / White |
Imaging Mode | : | Colour |
Image Freezing Control | : | Finger Control, Footswitch / Software Control |
Minimum Illumination | : | 0.0 Siux |
Signal-to-Noise (SNR) | : | >50 db |
Electronic Shutter | : | 11/10, 000 sec |
Light Source | : | Multi-point surrounded high-brightness white cold light source |
Back-lighted | : | Compensation automatic |
Focus Area | : | 150 - 350mm |
Zoom Optical Varifocal | : | 32 times |
Digital Varifocal | : | 10 times |
Dynamic Timing Control | : | Real-time display of acetic acid and iodine reaction tests |
Video-out | : | PAL/NTSC 1.0 vp-p, 750 |
Software | : | Windows XP, V ISTA, 7 /8/10 Ultimate |
Winning Advantages:
Technical Specifications :
Injection Rate | : |
|
Rate Accuracy | : | Within 3% (after correct calibration) |
Mechanical Accuracy | : | Within 2% |
Purge Rate | : |
|
Bolus Rate | : |
|
Occlusion | : |
|
Volume Limit / Total Injection | : | 0.1 - 999.9ml (0.1ml step) |
KVO Speed | : | 0.1 5ml/h (0.1ml/h step). |
KVO Rate | : | 1ml/h |
Power Source | : | 100-240VAC, 50/60Hz. |
Power Consumption | : | 30VA. |
Dimension | : | 280(L)x210(W)x130mm(H). |
Net Weight | : | 2.2Kg. |
Winning Advantages:
Salient Features:
Lead | : | Standard 12 leads |
Acquisition | : | Simultaneous 12 leads |
A/D Converter | : | 14bit |
Sampling Rate | : | 1000Hz |
Working Mode | : | Manual/Auto |
Interference Filter | : | AC Filter and EMG Filter |
CMMR | : | ≥100dB (with AC filter) |
Input Circuit | : | Floating, protection circuit against defibrillator effect |
Input Circuit Current | : | ≤0.1μA |
Input Impedance | : | ≥50MΩ |
Patient Current Leakage | : | <10μA |
Calibrating Voltage | : | 1mV±2% |
Polarization Voltage Tolerance | : | ≥±500mV |
Time Constant | : | ≥3.2s |
Frequency Response | : | 0.05 Hz~250Hz |
Noise Level | : | <15μVp-p |
Sensitivity Threshold | : | ≤20μV |
Printer | : | Thermal printer |
Paper | : | 80mmx20m, roll |
Page Speed | : | 6.25, 12.5, 25, 50mm/s (±3%) |
Sensitivity | : | 10mm/mV (AUTO), 2.5, 5, 10, 20mm/mV |
Safe Class | : | GB9706.1, Class I, Type CF |
Power Supply | : | AC 220V (±10%), 50Hz±1Hz, Power ≤60VA ; DC14.8V (2000mAh), rechargeable Li-ion battery |
Dimension | : | 310mm×270mm×73mm |
Weight | : | 1.45 kg (with battery) |
Functions:
Uses high current to ionize argon gas and release the energy to cut and coagulate the body tissues.
Winning Advantages:
Applications:
Therapy surgery of Gynecology, E.N.T, Surgery under the celoscope and bonchoscope, bipolar electrosurgical cut surgery of prostate and uterus cavity.
echnical Specifications :
Basic Frequency of Electrosurgical unit | : | 512KHz / 300KHz |
Output Power | : | 350W(iE-800A), 300W(iE-800BI), 200W(iE-800BII) |
Argon Output flow range | : | 0.1 - 12 L/min |
Regulating Step | : | 0.1L/min, 0.2L/min,0.5L/min,1.0L/min |
Argon Purity | : | 99.99% |
Capacity | : | 1 bottle - 6L ( single channel) for iE-800E1 |
: | 2 bottles - 6L* 2 (double channel) foriE-800E2 | |
Classification | : | Class I, Type CF |
Voltage & Frequency | : | 220Vs +/- 10% ; 50 Hz |
Dimension of Gas controller (cm) | : | (L) 40 × (W) 42 × (H) 15 |
Technical Specifications :
Voltage | : | 220V±22V 50Hz±1Hz |
Input Power | : | 120 A |
Noise | : | ≤60dB (A) |
Max Negative Pressure | : | ≥0.09MPa |
Max Pumping Rate | : | 30L/min |
Continuous Working Time | : | 0-30 min |
Rest Time | : | 30min |
Bottle Volume | : | 2500 ml glass bottle, 2 pcs |
Technical Specifications :
Oxygen Density | 93%3% V/V |
Running Noise | 48dBA |
Max. flow | 3L/min |
Power consumption | 320W |
Net Wt. | 20kg |
Dimension | 395x310x610 (LxWxH)mm |
Continuous Working Time | 10000hours |
Winning Advantages:
Basic function:Time counting, Power off alarm and abnormal voltage alarm, Timing & Remote control.
Technical Specifications:
Power Supply: AC100240V, 50/60HZ, Adapter: Output 9VDC, 5A
Battery:2500mAh 7.4V Rechargeable battery. Rated Charging Current:1250mA. Charge Cycle : 300 times
Working time:2hours
ECG: Lead Mode:3/5 Leads, I, II, III orI, II, III, AVR, AVL, AVF, V.Gain:2.5, 5.0mm/mV, 10mm/mV, 20mm/mV
Heart Rate: Measure Range : Adult : 15 300 bpm; Neonatal/Pediatric : 15350bpm, Accuracy : 1% Resolution :1 bpm; Differential Input Impedance> 5 M ohm
CMRR: Diagnostic Mode>90 dB; Monitor Mode >105 dB; Surgery Mode >105 dB; Leakage Current< 10 A
PACE Pulse Detects:Range : 2700mV ; Width : 0.12ms ; Rise Time : 10100s
Bandwidth:Surgery:1 20 Hz; Monitor : 0.5 35 Hz; Diagnostic : 0.05 130 Hz
ST Measurement: Range : -2.0 +2.0 mV ; Accuracy : -0.8mV+0.8mV: 0.02mV or 10%, which is greater
Other Range:unspecified
Respiration:Method Impedance between RA-LL, RA-LA; Differential Input Impedance>2.5 M ohm;
Respiration Impedance Range:0.33; Base Impedance Range : 200-4000; Bandwidth 0.3 2.5 Hz
Gain *0.25, *0.50, *1, *2,
Respiration Rate :Adult : 0 120 BrPM; Neonatal /Pediatric:0 150 BrPM; Resolution:1 BrPM; Accuracy:2 BrPM or 2%, use the greater. Apnea Alarm:10 40 s
NIBP:Method Oscillometric; Measure Mode : Manual, Auto, STAT; Measure Interval in AUTO Mode 199 min; Measure and Alarm Range : 0mmHg0kPa300mmHg40.0kPa; Static Pressure Accuracy : 3mmHg
Resolution: 1mmHg;
Accuracy: Maximum Mean error : 5mmHg; Maximum Standard Deviation : 8mmHg
Overpressure Protection: Adult : 300 mmHg;Pediatric : 240mmHg;Neonatal : 150 mmHg
SpO2:Measurement Range : 0 100 % ; Resolution : 1 %;
Accuracy:
70% 100% | 2 % |
40% 69% | 3 % |
0% 39% | unspecified |
Pulse Rate: Measure and Alarm Range : 20300bpm; Resolution : 1bpm; Accuracy : 3bpm
Temperature:Measure and Alarm Range : 0 50 C; Resolution : 0.1C
CO2(optional):MeasureRange : 0% 13%; Resolution : 1 mmHg; Breath Rate : 0 - 150 bpm
Recorder(optional):Paper Width : 50mm; Speed : 12.5/25/50 mm/s; WaveChannel : 3channels
Dimension & Weight:210 130 75mm; About 1Kg
Technical Specifications:
Display :12.1 inch LED (0-90 degree rotation)
Resolution :1024*768 pixels
Power supply and battery :100 - 240 VAC, 50 / 60Hz; Input Power: 70 to 100 VA
Battery :Rechargeable lithium battery : 14.8 V / 2200 mAh; Charge Cycle : more than 500 times
Working time :2 hours (optional larger battery for 4-5 hours)
Recorder (Built-in) :Thermal printer; Paper : Z-fold, thermo sensitive; Paper width: 112mm or 150mm; Print speed : 1/2/3 cm/min ; Trace : Max. 4 tracks ; Recording way : Real-time Recording ; Review printing
Alarm :Level : Low, Medium and High ; Indication : Auditory, Visual, delay of FHR alarm
Input Device :Knob, Keypad Input. Optional : Touch screen; Mouse / keyboard input
Trend & Reviewing :Cardiotocography (CTG) : Waveform review : 8640h; Vital signs: Trend graph and table : 2160h ; Waveform Review: 2h; Alarm Review : 2000 groups
Dimension and weight :360 * 310 * 120mm; 5.3KG (excluding accessories)
NST Report (Option)
Based on Fischer evaluation method (monitoring time 20 min)
Automatic Score result :
Score | 8 - 10 excellent |
Score | 5 - 7 suspicious |
Score | 0 - 4 foetus hypoxia |
Technical Specifications :
Technical Specifications :
Winning Advantages:
Winning Advantages:
Refractometer | ||
Vertex Distance | : | 0mm, 12mm,13.75mm |
Spherical | : | -20 - +20 D ( VD=12 ) 0.12 / 0.25D Step |
Cylinder | : | -8 - +8D 0.12 / 0.25D step |
Axis | : | 0-180D 1D step |
Cylinder Form | : | -, +, + |
Pupil Distance | : | 45 - 88mm, 1mm step |
Min. Pupil Size | : | 2.0mm |
Keratometry | ||
Radius of Curvature | : | 5.0 - 10 mm ( Increment : 0.01mm ) |
Corneal Power | : | 33.75 - 67.50 D ( when corner equivalent Refractive Index is 1.337 ) |
Corneal Astigmatism | : | 0.00 - 8.00 D ( Increment selectable from 0.12, 0.25D ) |
Axis | : | 1 - 180 D ( Increment : 1° ) |
Corneal Diameter | : | 2.0 -14 mm ( Increment : 0.1mm ) |
Memory of Data | : | 10 measure values for each Right and Left Eye |
Others |
Chart | : | Auto Fog |
Display | : | 5.7" color LCD ( ivR 68 & ivR 61 / ivK 61 ), 5.6 Color LCD ( ivR 60 ) |
: | Thermal Printer | |
Power supply | : | 100 – 240V 50/60HZ |
Dimension | : | 280 (w) x 540 (L) x 509 mm (H) ( ivR 68 ), |
280 (w) x 492 (L) x 462mm (H) ( ivR 60 & ivR 61/ ivK 61 ) | ||
Weight | : | 22kg ( ivR 68 ) 20kg ( ivR 60 & ivR 61 / ivK 61 ) |
Winning Advantages:
Technical Specifications :
Range of Measurement
Sphere | : | 0~+- 25D, 0.01/0.12/0.25D step |
Cylinder | : | 0~ +-9.9 D 0.01/0.12/0.25D step |
Axis | : | 0-180 ° (1 ° step) |
Add | : | 0 - 9.99 D 0.01 / 0.12 / 0.25D step |
Prism Degree | : | 0 - 15 D 0.01 / 0.12 / 0.25D step |
Measurement Mode
Cylinder | : | +, +/-, - |
Prism | : | X-Y, P-B |
Contact Lens | : | Soft / hard; |
Measuring mode | : | Single / Progressive / Automatic Recognition |
Specifications:
Lens Diameter | : | 20 - 108mm; |
PD | : | 40 - 90mm, 0.5mm step |
Measurement Speed | : | 0.1s |
Display | : | 7'' TFT LCD |
Printer | : | ivL 20 : Thermal, ivL 20B : No printer |
Weight | : | 6kg |
Power supply | : | 100-240V, 50-60HZ |
Winning Advantages:
Technical Specifications :
Microscope Type | : | Converging |
Magnification Change Way | : | Deflector Rod |
Eyepiece Magnification | : | 10x 16x |
Total Magnifications | : | 10x 16x 25x |
Diopter Adjustment | : | -5D ~+5D |
Slit Width | : | 0 - 14mm Continuous |
Slit Height | : | 1 - 14mm Continuous |
Slit Angle | : | 0°- 180° Adjustable |
Slit Inclination Angle | : | 5°,10°,15°,20° |
Light Spot Diameter | : | 0.2mm, 2mm, 3mm, 5mm, 10mm,14mm |
Filter | : | Heat Absorption; Grey; Red free; Cobalt Blue |
Fixation | : | Red LED |
Illumination Bulb | : | German OSRAM Halogen Tungsten Lamp |
Winning Advantages:
Microscope | ||
Microscope Type | Galilean Type | |
Magnification Change | : | Revolving Drum (5 or 3 steps) |
Total Magnification | : | 6X, 10X, 16X, 25X, 40X (ivSM 28) |
10X, 16X, 25X (ivSM 28S) |
Eyepieces | : | 12.5X |
Angle between Eyepieces | : | 13° |
Pupillary Adjustment | : | 52mm-78mm |
Diopter Adjustment | : | ±6D |
Field of View | : | ivSM 26: 34.7mm(6X), 22mm(10X), 13.5mm(16X), 8.5mm(25X), 5.5mm(40X) |
ivSM 26S: 22mm(10X), 13.5mm(16X), 8.5mm(25X) | ||
Slit Illumination | ||
Slit Width | : | 0 ~ 14mm continuous (slit becomes a circle at 14mm) |
Slit Length | : | 1~14mm continuous |
Aperture Diameters | : | Φ14mm, Φ8mm, Φ3.5mm, Φ0.5mm |
Slit Angle | : | 0°-180° |
Filters | : | Heat-absorbing Filter, Red-free Filter, Cobalt Blue Filter |
Lamp | : | 3V/3W LED Lamp |
Luminance | : | ≥60KLX |
Instrument Base | ||
Longitudinal Movement | : | 110mm |
Lateral Movement | : | 110mm |
Vertical Movement | : | 30mm |
Fine Base Movement | : | 15mm |
Chin-rest | ||
Vertical Movement | : | 80mm |
Fixation | : | LED |
Power Supply | ||
Input Voltage | : | 220v/110v~±10% |
Input Frequency | : | 50Hz/60Hz |
Power Consumption | : | 20VA (max) |
Output Voltage | : | Lamp 3V, Fixation 3V |
Packaging | ||
Dimension / Gross Weight | : | 760mm x 470mm x 570mm (L/W/H) / 22 kgs |
Winning Advantages:
Technical Specifications :
Model | : | Placido cone |
Measuring method | 10.91 mm (Diameter) | |
Coverage | 5.5 - 10.0 mm |
Measuring range for curvature radius | : | 33.75D-61.36D |
Diopter range | : | ±0.02 mm |
Precision | : | 31 rings |
Operating Temperature | : | 7,936 points |
Measurement points | : | 7936 points |
Display | : | Axial curvature map, Tangential curvature map, Elevation map, |
Imitated Keratoscope map and 3D Cornea map | ||
Image output | : | High-quality color inkjet printer |
Adjust range | : | left/right 86mm ; forward/backward 40mm ; up/down 30mm ; chin rest 50mm |
Cornea contact lenses fitting function | ||
Keratoconus detecting function |
Technical Specifications :
A Scan Probe | 10MHz import small size probe, built-in luminotron |
Measuring Range | 15 - 40mm |
Measurement Precision | 0. 05mm; with macula lutea trace function |
Measurement | Anterior chamber depth, lens thickness, vitreous body length, total length and average |
Method of Measurement | immersion and contact |
Eye mode | Phakic / Aphakic / Dense / various IOL |
IOL formula | SRK-II, SRK-T, BINKHORST- II, HOLLADAY, HOFFER |
Storage | 10 cases, 5 readings each case |
Output | A scan waveform and IOL calculation sheet |
Winning Advantages:
Winning Advantages:
Technical Specifications :
Stimulus Type | : | LED |
Stimulator Screen | Hemispherical bowl, radius 30cm integrated | |
Stimulus source | Light Emitting diode |
Stimulus Size | : | Goldman III |
Stimulus Intensity | : | ≤10000asb |
Stimulus Duration | : | Adjustable 0.2 to 2 Second |
Stimulus color | : | Yellow; Red |
Stimulus step | : | TOTAL 27, STEP 1 |
Minimum Inter-stimulus delay | : | Adjustable 0.2 to 2 seconds |
Background Illumination | : | 4 abs |
Lens Holder Diameter | : | 35mm (optional) |
Stimulus Points | : | 144(0-60D),72 (0-30D), 61(0-10D red), 114 (Blind spot) |
Chin-rest moving range | : | Vertical 70mm, horizontal 90m |
Fixation Method | : | Automatic monitoring with two options. Available blind spot method, Eye tracking method. In both methods, fixation errors are to be immediately announced by visual and audible warnings. The standard video camera should provide visual of the patient's eye for additional monitoring. |
Test Range | : | Default test (0-60D), Yellow spot test (central 0-10D), Central 0-30D test, Quadrant test, Peripheral test (60-90D), Blind spot test, Custom Test. |
Winning Advantages:
Technical Specifications :
Tomographic Imaging | ||
Purpose | Cross Sectional Imaging of the Retina | |
Signal Type | Photon scattering from tissue |
Light Source | : | Super luminescent diode, 830nm |
Optical Power | : | ≤ 0.7mW (on the cornea) |
Axial Resolution | : | 5 - 8 um in tissue |
Lateral Resolution | : | 15 um in tissue |
Scanners | : | Galvanometer Mirror |
Scan Mode | : | Line, Concentric ring, Repeat, Arbitrary-angle |
Scan Rate | : | 400 A - scan/s |
Acquisition Time | : | 1 sec |
Scan Depth | : | 2mm in tissue |
Fundus Imaging | ||
Purpose | : | Fundus observation and real-time registration of OCT imaging |
Signal Type | : | CCD imaging |
Field Angle | : | 29°x 23° |
Viewing Method | : | 15 inch color flat panel display |
Illumination | : | LED |
Internal Fixation | : | LED dot matrix |
External Fixation | : | Adjustable blinking LED |
Minimum Pupil Diameter | : | 3.5mm |
Winning Advantages:
Technical Specifications :
Size of Diamond wheel (Diameter | : | Cr wheel 100x16, Glass wheel 100x16 |
& Width of Grinding Wheel mm) | V groove wheel 100x23 Polishing sheel 100x11 | |
Available Lens Range | : | 22 ~ 100mm |
Processing Type | : | Pointy edges, Plat Band, Bevel Polishing |
Lens Material | : | CR, Glass |
Size in mm | : | 510 (l) x 490 (w) x 400 (h) |
Weight | : | 49 kgs |
Voltage | : | Voltage 220v ±10% frequency 50hz |
Power | : | 500w |
Winning Advantages:
Technical Specifications :
Eye piece Magnification | : | 12.5x/18B |
Objective Focus | : | f=200mm |
Working Distance | : | 195mm |
Magnification for Main Microscope | : | 4.6x ~27x zoom magnification |
Magnification for Assistant Microscope | : | 6.2x, 9.3x, 14x |
Diameter of Field | : | ∮46mm ~8.5mm |
Adjustable Diopter | : | ±6D |
Adjustable Range of Pupil Distance | : | 55mm ~ 75mm |
Maximal Resolution | : | 126LP/m |
Illumination Source | : | 15V/150W, Medical cold-reflection Halogen Lamp |
Illumination Type | : | 6°Coaxial illumination, 6°± 2° Coaxial illumination |
Filter | : | UV& IR filter, yellow spot protection filter, red free, GG435, GG475 |
Maximal Illumination | : | ≥ 50000 lx |
Maximal Height for Microscope | : | 1710mm |
Reaching Radius of Arm | : | 1320mm |
Adjustable Vertical Range | : | 710mm ~ 1310mm |
Fine Focus Speed and Range | : | ≤ 2mm/s, 50mm |
Speed for X/Y and Range | : | ≤ 2mm/s, 50mm |
Arthrosis Fixation | : | Electromagnetic Lock |
Input Voltage | : | AC 220V ± 10% /50HZ ±1HZ, AC 110V±10%/60HZ ±1Hz |
Power | : | 480VA |
Fuse | : | AC 250V T5.0A AL (51S-050H), AC 125V T 10.0AL (51S-01DDL_ |
Electrical Safety Standard | : | Executive to GB 9706.1-2007, Class I |
Packing Volume | : | 1.494cbm, 5 cartons |
Total Gross Weight | : | 302kg |
Optional Objectives | : | F= 250mm/300mm/350mm/400 |
Specifications Flat Panel Detector:
Specifications Imaging Work Station:
Industry high-end CT Scanner most use large aperture to Ensure image high quality Bound to the overall advantages of the image chain take shape challenge
Three classic CT adopt international first-class technology, polymeric global R & D Power.
Use low dosage to achieve high image quality and streamline workflow.
Designed to provide to users with first class product's services and long term economic benefits.
Smooth and Efficient Operation
Stable System Performance to meet the requirements of high usage Giving Smooth Operation and Somatosensory using :
Conventional CT Medical Diagnostic Platforms and Systems Special Use Cases of Obese Patients Radiotherapy Positioning
HDimages | With fast acquisition and post-processing to provide High Quality Diagnostic Images Fine clear Image reconstruction, Steadily increase the resolultion Sharp boundary, Good Density Contrast |
Technical Specifications
Insitum 32 CT system |
||||||
Item |
Descriptions |
|||||
General |
Aperture |
760mm |
||||
Heat capability |
5.3MHU |
|||||
Powering rate |
50KW |
|||||
Reconstruction Speed |
16 images /s |
|||||
Partial scans |
0.5s |
|||||
In plane spatial resolution |
20 lp/cm |
|||||
Detector rows |
32 |
|||||
Gantry |
Aperture |
760 |
||||
Tilt range |
±30° |
|||||
Tube |
Heat capability |
5.3MHU |
||||
Heat dissipation |
815KHU/min |
|||||
Focal spot sizes |
0.5mm×1.0mm 1.0mm×1.0mm |
|||||
Method of cooling |
Oil to air |
|||||
Generator |
Powering rate |
50KW |
||||
KV range |
80kV, 100kV, 120kV, 140KV |
|||||
MA range |
10-420mA |
|||||
Continuous Scan time |
100s |
|||||
Patient Couch |
Scan range |
180cm |
||||
Max. patient load |
250 |
|||||
Console |
Pitch range |
0.3-1.5 |
||||
Reconstruction Speed |
16 images/s |
|||||
Image area matrix dimensions |
1024x1024 |
|||||
IOperating system |
windows XP win 7 |
|||||
Detection Systems Helical and anxial scanning |
Detector type |
Solid state(High speed ceramic) |
||||
Number of detectors |
27648 |
|||||
Detector rows |
32 |
|||||
Detector row slice Thickness |
32X0.625mm |
|||||
Detector coverage |
20mm |
|||||
Rotation times for axial scans(s)* =Partial scans "Helical acquisition widths Helical acquisition widths (number of channels x width, mm) |
0.5S 32X0.625mm |
|||||
Performance data |
In plane spatial resolution (Ip/cm) for sharpest clinical algorithm. Acquisition parameters in brackets |
20. lp/cm |
||||
Contrast resolution:smallest rod size(mm)discernable at given parameters in 20cm CATPHAN |
3.0mm @0.3% |
|||||
Console computer system |
Operating system |
WindowsXP |
||||
CPU |
Intel Xeon E5-1620V3 3.5GHz |
|||||
Hard disk |
≥5T |
|||||
RAM |
≥ 32G |
|||||
Display Device |
≥24'' TFT |
|||||
Image reconstruction speed |
16 image/s |
|||||
Automatic photography |
YES |
|||||
Automated voice systems and two-way voice transmission |
YES |
|||||
Synchronous parallel image processing functions |
YES |
|||||
Input and output |
DICOM3.0 |
|||||
Software Performance |
Automatic mA control |
|||||
MIP (maximum intensity projection) |
||||||
MinIP (minimum intensity projection) |
||||||
MPR (multiplanar reconstruction) |
||||||
CPR (curve planar reconstruction ) |
||||||
SSD (shaded surface display) |
||||||
VR (volume rendering) |
||||||
CTA |
||||||
Breath control voice prompt |
||||||
X-ray intelligent control technology |
||||||
Beam hardening artifacts correction software |
||||||
Posterior fossa image optimization techniques (bone hardening) |
||||||
Metal artifacts reduction (MAR) algorithm |
||||||
Scalpel simulation functions |
||||||
3D volume measurement evaluation function |
||||||
One-click volume reconstruction |
||||||
Three-dimensional CT virtual endoscopy (CTVE) |
||||||
One-click boneless function |
||||||
Automatic tracking of contrast agent software |
||||||
Scanning protocol for children |
||||||
3D lung nodules evaluation software |
||||||
Power Supply |
3N~380/400V 50/60Hz 70KVA |
|||||
Typical Layout |
Item |
S iz e |
||||
Observation window |
1.5m x 0.8m |
|||||
Equipment Room |
6.0m x 5.0m x 2.8m |
|||||
Control Room |
3.0m x 5m x 2.8m |
|||||
Total MRI-System area |
54 m2 |
|||||